Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Marquette University

Series

Hindfoot

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Sagittal Subtalar And Talocrural Joint Assessment During Ambulation With Controlled Ankle Movement (Cam) Boots, Ben Mchenry, Emily L. Exten, Janelle A. Cross, Karen M. Kruger, Brian Law, Jessica M. Fritz, Gerald F. Harris Nov 2017

Sagittal Subtalar And Talocrural Joint Assessment During Ambulation With Controlled Ankle Movement (Cam) Boots, Ben Mchenry, Emily L. Exten, Janelle A. Cross, Karen M. Kruger, Brian Law, Jessica M. Fritz, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

Background: The purpose of the current study was to determine sagittal plane talocrural and subtalar kinematic differences between barefoot and controlled ankle movement (CAM) boot walking. This study used fluoroscopic images to determine talar motion relative to tibia and calcaneal motion relative to talus.

Methods: Fourteen male subjects (mean age 24.1 ± 3.5 years) screened for normal gait were tested. A fluoroscopy unit was used to collect images at 200 Hz during stance. Sagittal motion of the talocrural and subtalar joints were analyzed barefoot and within short and tall CAM boots.

Results: Barefoot talocrural mean maximum plantar and dorsiflexion were …


Biplane Fluoroscopy For Hindfoot Motion Analysis During Gait: A Model-Based Evaluation, Janelle A. Cross, Ben Mchenry, Robert C. Molthen, Emily Exten, Taly Gilat-Schmidt, Gerald F. Harris May 2017

Biplane Fluoroscopy For Hindfoot Motion Analysis During Gait: A Model-Based Evaluation, Janelle A. Cross, Ben Mchenry, Robert C. Molthen, Emily Exten, Taly Gilat-Schmidt, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

The purpose of this study was to quantify the accuracy and precision of a biplane fluoroscopy system for model-based tracking of in vivo hindfoot motion during over-ground gait. Gait was simulated by manually manipulating a cadaver foot specimen through a biplane fluoroscopy system attached to a walkway. Three 1.6-mm diameter steel beads were implanted into the specimen to provide marker-based tracking measurements for comparison to model-based tracking. A CT scan was acquired to define a gold standard of implanted bead positions and to create 3D models for model-based tracking. Static and dynamic trials manipulating the specimen through the capture volume …


Sagittal Subtalar And Talocrural Joint Assessment With Weight-Bearing Fluoroscopy During Barefoot Ambulation, Ben Mchenry, Emily L. Exten, Jason Long, Brian Law, Richard Marks, Gerald F. Harris Apr 2015

Sagittal Subtalar And Talocrural Joint Assessment With Weight-Bearing Fluoroscopy During Barefoot Ambulation, Ben Mchenry, Emily L. Exten, Jason Long, Brian Law, Richard Marks, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

Background: Identifying talar position during ambulation has proved difficult as the talus lacks palpable landmarks for skin marker placement and more invasive methodologies such as bone pins are not practical for most clinical subjects. A fluoroscopic motion system was used to track the talus and calcaneus, allowing kinematic analysis of the talocrural and subtalar joints.

Methods: Thirteen male subjects (mean age 22.9 ± 3.0 years) previously screened for normal gait were tested. A fluoroscopy unit was used to collect images at 120 fps during stance. Sagittal motion of the talocrural and subtalar joints were analyzed.

Results: The intersubject mean and …