Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Engineering

Repair Severed Nerve Connections Through A Multi-Branch Microchannel Scaffold To Control The Direction Of The Regenerated Nerve, Luis Enrique Castanuela Ramon Aug 2016

Repair Severed Nerve Connections Through A Multi-Branch Microchannel Scaffold To Control The Direction Of The Regenerated Nerve, Luis Enrique Castanuela Ramon

Theses and Dissertations

Damage to the peripheral nervous system may result in functional abnormalities due to disrupted nerve connections. Existing methods of repairing severed nerve connections in the peripheral nervous system have limitations and disadvantages such as a limited availability of donor nerves and a lack of control of the direction of nerve regeneration within nerve conduits. A handcrafted multi-branch microchannel scaffold improves upon the current methods of nerve repair by incorporating microchannels, which guide and accommodate the nerve regeneration to distal ends, allowing for the treatment of nerve injuries involving multiple branches with fewer surgeries. This scaffold is also made more accessible …


Microwire Regenerative Peripheral Nerve Interfaces With Wireless Recording And Stimulation Capabilities, Ali Ajam May 2016

Microwire Regenerative Peripheral Nerve Interfaces With Wireless Recording And Stimulation Capabilities, Ali Ajam

Theses and Dissertations

A scalable microwire peripheral nerve interface was developed, which interacted with regenerated peripheral nerves in microchannel scaffolds. Neural interface technologies are envisioned to facilitate direct connections between the nervous system and external technologies such as limb prosthetics or data acquisition systems for further processing. Presented here is an animal study using a handcrafted microwire regenerative peripheral nerve interface, a novel neural interface device for communicating with peripheral nerves. The neural interface studies using animal models are crucial in the evaluation of efficacy and safety of implantable medical devices before their use in clinical studies.16-electrode microwire microchannel scaffolds were developed for …


Microfluidic Devices And Biosensors, Long-Fang Tsai Feb 2016

Microfluidic Devices And Biosensors, Long-Fang Tsai

Theses and Dissertations

My research broadly covers various important aspects of microfluidic devices and biosensors. Specifically, this dissertation reports: (1) a new and effective room temperature method of bonding polydimethylsiloxane (PDMS) microfluidics to substrates such as silicon and glass, (2) a new microfluidic pump concept and implementation specifically designed to repeatedly drive a small sample volume (<1 µL) very rapidly (~500 µL/min) through a sensor-containing flow channel to significantly decrease sensor response time through advection-driven rather than diffusion-driven mass transport, (3) use of a new microfluidic material based on polyethylene glycol diacrylate (PEGDA) to implement impedance-based dynamic nanochannel sensors for protein sensing, and (4) an investigation of galvanoluminescence and how to avoid it for conditions important to fluorescence-based dielectrophoresis (DEP) microfluidic biosensors. Over the last decade, the Nordin research group has developed a lab-on-a-chip (LOC) biosensor based on silicon photonic microcantilever arrays integrated with polydimethylsiloxane (PDMS) microfluidics for protein biomarker detection. Integration requires reliable bonding at room temperature with adequate bond strength between the PDMS element and microcantilever sensor substrate. The requirement for a room temperature process is particularly critical because microcantilevers must be individually functionalized with antibody-based receptor molecules prior to bonding and cannot withstand significant heating after functionalization. I developed a new room temperature bonding method using PDMS curing agent as an intermediate adhesive layer. Two curing agents (Sylgard 184 and 182) were compared, as well as an alternate UV curable adhesive (NOA 75). The bond strength of Sylgard 184 was found to be stronger than Sylgard 182 under the same curing conditions. Overnight room temperature curing with Sylgard 184 yields an average burst pressure of 433 kPa, which is more than adequate for many PDMS sensor devices. In contrast, UV curable epoxy required a 12 hour bake at 50 °C to achieve maximum bond strength, which resulted in a burst pressure of only 124 kPa. In many biosensing scenarios it is desirable to use a small sample volume (<1 µL) to detect small analyte concentrations in as short a time as possible. I report a new microfluidic pump to address this need, which we call a reflow pump. It is designed to rapidly pump a small sample volume back and forth in a flow channel. Ultimately, the flow channel would contain functionalized sensor surfaces. The rapid flow permits use of advection-driven mass transport to the sensor surfaces to dramatically reduce sensor response times compared to diffusion-based mass transport. Normally such rapid flow would have the effect of decreasing the fraction of analyte molecules in the volume that would see the sensor surfaces. By configuring the pump to reflow fluid back and forth in the flow channel, the analyte molecules in the small sample volume are used efficiently in that they have many opportunities to make it to the sensor surfaces. I describe a 3-layer PDMS reflow pump that pumps 300 nL of fluid at 500 µL/min for 15 psi actuation pressure, and demonstrate a new two-layer configuration that significantly simplifies pump fabrication. Impedance-based nanochannel sensors operate on the basis of capturing target molecules in nanochannels such that impedance through the nanochannels is increased. While simple in concept, the response time can be quite long (8~12 hours) because the achievable flow rate through a nanochannel is very limited. An approach to dramatically increase the flow rate is to form nanochannels only during impedance measurements, and otherwise have an array of nanotrenches on the surface of a conventional microfluidic flow channel where they are exposed to normal microfluidic flow rates. I have implemented such a dynamic nanochannel approach with a recently-developed microfluidic material based polyethylene glycol diacrylate (PEGDA). I present the design, fabrication, and testing of PEGDA dynamic nanochannel array sensors, and demonstrate an 11.2 % increase in nanochannel impedance when exposed to 7.2 µM bovine serum albumin (BSA) in phosphate buffered saline (PBS). Recently, LOC biosensors for cancer cell detection have been demonstrated based on a combination of dielectrophoresis (DEP) and fluorescence detection. For fluorescence detection it is critical to minimize other sources of light in the system. However, reported devices use a non-noble metal electrode, indium tin oxide (ITO), to take advantage of its optical transparency. Unfortunately, use of non-noble metal electrodes can result in galvanoluminescence (GL) in which the AC voltage applied to the electrodes to achieve DEP causes light emission, which can potentially confound the fluorescence measurement. I designed and fabricated two types of devices to examine and identify conditions that lead to GL. Based on my observations, I have developed a method to avoid GL that involves measuring the impedance spectrum of a DEP device and choosing an operating frequency in the resistive portion of the spectrum. I also measure the emission spectrum of twelve salt solutions, all of which exhibited broadband GL. Finally, I show that in addition to Au, Cr and Ni do not exhibit GL, are therefore potentially attractive as low cost DEP electrode materials.


Characterization Of Poly(Dimethylsiloxane) Blends And Fabrication Of Soft Micropillar Arrays For Force Detection, Thomas J. Petet Jr Jan 2016

Characterization Of Poly(Dimethylsiloxane) Blends And Fabrication Of Soft Micropillar Arrays For Force Detection, Thomas J. Petet Jr

Theses and Dissertations

Diseases involving fibrosis cause tens of thousands of deaths per year in the US alone. These diseases are characterized by a large amount of extracellular matrix, causing stiff abnormal tissues that may not function correctly. To take steps towards curing these diseases, a fundamental understanding of how cells interact with their substrate and how mechanical forces alter signaling pathways is vital. Studying the mechanobiology of cells and the interaction between a cell and its extracellular matrix can help explain the mechanisms behind stem cell differentiation, cell migration, and metastasis. Due to the correlation between force, extracellular matrix assembly, and substrate …