Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Precision Of Emr Data: The Case For A Drug And Alcohol Service, Siyu Qian, Esther Munyisia, Ping Yu, David M. Hailey, David Reid Jan 2017

Precision Of Emr Data: The Case For A Drug And Alcohol Service, Siyu Qian, Esther Munyisia, Ping Yu, David M. Hailey, David Reid

Faculty of Engineering and Information Sciences - Papers: Part B

Error-laden data can negatively affect clinical and operational decision making, research findings and funding allocation. This study examined the number and types of data errors in an electronic medical record (EMR) system in a Drug and Alcohol service. Specifically, errors in service data were examined. 9,379 errors were identified from ten error reports generated between March 2015 and May 2016, three months after the implementation of the EMR system. These errors were grouped into four types: mismatched data fields (60.5%), duplicate medical record error (3.2%), date/time error (8.8%) and blank field error (27.4%). The errors can be prevented by adding …


In Vitro Mechanical Fatigue Behavior Of Poly-Ɛ-Caprolactone Macroporous Scaffolds For Cartilage Tissue Engineering: Influence Of Pore Filling By A Poly(Vinyl Alcohol) Gel, J A. Panadero, L Vikingsson, J L. Gomez Ribelles, Senentxu Lanceros-Méndez, Vitor Sencadas Jan 2015

In Vitro Mechanical Fatigue Behavior Of Poly-Ɛ-Caprolactone Macroporous Scaffolds For Cartilage Tissue Engineering: Influence Of Pore Filling By A Poly(Vinyl Alcohol) Gel, J A. Panadero, L Vikingsson, J L. Gomez Ribelles, Senentxu Lanceros-Méndez, Vitor Sencadas

Faculty of Engineering and Information Sciences - Papers: Part A

Polymeric scaffolds used in regenerative therapies are implanted in the damaged tissue and submitted to repeated loading cycles. In the case of articular cartilage engineering, an implanted scaffold is typically subjected to long-term dynamic compression. The evolution of the mechanical properties of the scaffold during bioresorption has been deeply studied in the past, but the possibility of failure due to mechanical fatigue has not been properly addressed. Nevertheless, the macroporous scaffold is susceptible to failure after repeated loading-unloading cycles. In this work fatigue studies of polycaprolactone scaffolds were carried by subjecting the scaffold to repeated compression cycles in conditions simulating …


Low-Energy Electron Scattering From Α-Tetrahydrofurfuryl Alcohol, Luca Chiari, Darryl Jones, Penny Thoi, Michael J. Brungei, Gustavo Garcia, Francisco Blanco Jan 2014

Low-Energy Electron Scattering From Α-Tetrahydrofurfuryl Alcohol, Luca Chiari, Darryl Jones, Penny Thoi, Michael J. Brungei, Gustavo Garcia, Francisco Blanco

Faculty of Engineering and Information Sciences - Papers: Part A

We report on differential cross section results for low-energy electron collisions with the biologically relevant species a-tetrahydrofurfuryl alcohol. Electron-impact excitation measurements of the electronic states of a-tetrahydrofurfuryl alcohol were carried out at incident energies between 15-50 eV and for scattering angles in the range 20-90 degrees. Elastic differential cross section have also been calculated within the Independent Atom Model and using the Screening Corrected Additivity Rule approach at selected energies between 1-1000 eV.