Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Engineering

A Sensitivity Analysis Toolkit For The Simplification Of Mv Distribution Network Voltage Management, Fabian Tamp, Philip Ciufo Dec 2013

A Sensitivity Analysis Toolkit For The Simplification Of Mv Distribution Network Voltage Management, Fabian Tamp, Philip Ciufo

Dr Philip Ciufo

As distribution networks become increasingly variable and generation becomes increasingly decentralised, voltage standards are becoming more liable to violation. Accordingly, intelligent voltage management strategies are required to enable standards compliance without unduly increasing network maintenance or infrastructure costs. The relationship between network power and voltages, however, is complex, non-linear and interdependent, and thus is difficult to conceptualise and use for decision-making and control purposes.

This paper introduces a software toolkit that simplifies the development of voltage management strategies by the applica- tion of sensitivity analysis. Sensitivity analysis reduces complex network P – Q – |V | relationships to simple linear …


A Study On The Suitability Of Cable Models To Simulate Switching Transients In A 132 Kv Underground Cable, Muhamad Zalani Daud, P Ciufo, S Perera Dec 2012

A Study On The Suitability Of Cable Models To Simulate Switching Transients In A 132 Kv Underground Cable, Muhamad Zalani Daud, P Ciufo, S Perera

Dr Philip Ciufo

Switching transients resulting from the energisation of high voltage cable systems may have a significant effect on both the cables being switched as well as the power system components in the vicinity. The impacts of these transients on such cables are measured based on the stress arising as a result of the voltage and current peaks and the frequency of oscillatory transients. These quantities are typically obtained from a simulation by using a suitable cable model, normally with the capability to predict the transient behaviour in the range up to several 10 kHz. To obtain a cable model that enables …


Voltage Unbalance Emission Assessment In Interconnected Power Systems, Upuli Jayatunga, Sarath Perera, Philip Ciufo, Ashish P. Agalgaonkar Dec 2012

Voltage Unbalance Emission Assessment In Interconnected Power Systems, Upuli Jayatunga, Sarath Perera, Philip Ciufo, Ashish P. Agalgaonkar

Dr Philip Ciufo

The International Electrotechnical Commission (IEC) Technical Report IEC/TR 61000-3-13:2008 considers voltage unbalance (VU) emission assessment as a key aspect of the VU management of power systems. Compliance assessment of unbalanced installations at the post connection stage is essential to ensure that the limits set by the IEC VU emission allocation methodology in the pre-connection stage are met. Although, VU is known to be caused by load asymmetries and inherent network asymmetries, locating all VU emission sources is not a straightforward process, especially in a network with interconnections. Such assessment methodologies should ensure that the contributions from various sources of unbalance …


Point Of Common Coupling (Pcc) Voltage Control Of A Grid-Connected Solar Photovoltaic (Pv) System, Brian Perera, Philip Ciufo, Sarath Perera Dec 2012

Point Of Common Coupling (Pcc) Voltage Control Of A Grid-Connected Solar Photovoltaic (Pv) System, Brian Perera, Philip Ciufo, Sarath Perera

Dr Philip Ciufo

In future low voltage grids, with multiple inverter interfaced sources connected, voltage regulation may become a necessary task. The potential exists for inverter interfaced sources to be deployed to regulate the voltage at the point of common coupling (PCC) of each inverter interfaced sources. The PCC voltage regulation is attainable with inverter interfaced sources by dynamically controlling the amount of reactive power injected to the power distribution grid by individual systems. In the current research, a closed-loop controller is proposed to regulate the PCC voltage of a solar photovoltaic (PV) system that is connected to a single-phase power distribution feeder …


Point Of Common Coupling (Pcc) Voltage Control Of A Grid-Connected Solar Photovoltaic (Pv) System, Brian Perera, Philip Ciufo, Sarath Perera Dec 2012

Point Of Common Coupling (Pcc) Voltage Control Of A Grid-Connected Solar Photovoltaic (Pv) System, Brian Perera, Philip Ciufo, Sarath Perera

Dr Philip Ciufo

In future low voltage grids, with multiple inverter interfaced sources connected, voltage regulation may become a necessary task. The potential exists for inverter interfaced sources to be deployed to regulate the voltage at the point of common coupling (PCC) of each inverter interfaced sources. The PCC voltage regulation is attainable with inverter interfaced sources by dynamically controlling the amount of reactive power injected to the power distribution grid by individual systems. In the current research, a closed-loop controller is proposed to regulate the PCC voltage of a solar photovoltaic (PV) system that is connected to a single-phase power distribution feeder …