Reliability Issues Caused By The Retirement Of Large Thermal Generation Facilities: An Irish Case Study, Kyle Lawson, Jane Courtney Jan 2019

Reliability Issues Caused By The Retirement Of Large Thermal Generation Facilities: An Irish Case Study, Kyle Lawson, Jane Courtney

Conference papers

Like all developed countries Ireland faces increasing pressure to reduce their carbon footprint. Part of the governments plans include the scaling back of fossil fuel generation facilities and increasing renewable resources. Moneypoint is Irelands only coal fired generation station. In 2025 Moneypoint is due to reach the end of its life cycle. At this point the Irish government will have to make a decission on the future of the generation facility. Currently Moneypoint is responsible for the generation of approximately 10 % of Irelands energy needs. In this paper, the removal of Moneypoint from the Irish generation portfolio will be …


Photovoltaic Supplied T-Type Three- Phase Inverter With Harmonic Current Compensation Capability, Zahera Batool, Samet Biricik, Hasan Komurcugil, Tuan Ngo, Tuyen V. Vu Jan 2019

Photovoltaic Supplied T-Type Three- Phase Inverter With Harmonic Current Compensation Capability, Zahera Batool, Samet Biricik, Hasan Komurcugil, Tuan Ngo, Tuyen V. Vu

Conference papers

In this paper, a T-Type grid-connected inverter with harmonic current compensation capability is proposed and studied for the on-grid photovoltaic (PV) systems. This idea is based on the modification of the existing photovoltaic inverter control algorithm with the adaptation of active power filter control algorithm. The grid-connected PV inverter has similar topology and control methods as that of the active power filter systems. However, such multifunctional inverters have not yet matured for commercial use and call for more research. In this work, a conventional phase locked-loop algorithm is used to determine the angular position of the synchronous reference of the …


Series Compensation To Increase Power Flow: A Case Study On The Irish Transmission System, Aidan Heffernan, Jane Courtney Jan 2019

Series Compensation To Increase Power Flow: A Case Study On The Irish Transmission System, Aidan Heffernan, Jane Courtney

Conference papers

Ireland presents an interesting case study for transmission network strengthening. The majority of load in the country is located at the nation's capital, Dublin, in the East, while most of the new conventional generation and renewable generation are found in the South-West. Power is transferred between the two via a 400 kV network. This leads to large cross- country power flows. This power distribution disparity is due to increase. A large thermal generating station which is connected to the 400 kV system in the West, will close by 2025. This generation will be replaced partially with wind generation in the …