Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Interferometer (2)
- Pressure sensor (2)
- Artificial neural networks (1)
- Bismuth (1)
- Cassegrain antenna (1)
-
- Charge compensation (1)
- Coherent sources (Optics) (1)
- Discrete energy levels (1)
- Dual parabolic reflector (1)
- Focal plane array (1)
- GEB (1)
- Gamma Spectrum (1)
- Gaussian Energy Broadening Constants (1)
- Heat transfer (1)
- High Purity Germanium HPGe (1)
- High power microwaves (1)
- LBO crystals (1)
- Large F/D Ratios (1)
- Laser speckle (1)
- Laser-induced breakdown spectroscopy (LIBS) (1)
- Lasers (1)
- Light guides (1)
- MCNP (1)
- Machine learning (1)
- Metamaterials (1)
- Modulation transfer function (MTF) (1)
- Nonlinear optics (1)
- Optical adsorption (1)
- Optical coupling (1)
- Optical fiber (1)
- Publication Type
Articles 1 - 13 of 13
Full-Text Articles in Engineering
Transition-Metal Ions In Β-Ga2O3 Crystals: Identification Of Ni Acceptors, Timothy D. Gustafson, Nancy C. Giles, Brian C. Holloway, J. Jesenovec, B. L. Dutton, M. D. Mccluskey, Larry E. Halliburton
Transition-Metal Ions In Β-Ga2O3 Crystals: Identification Of Ni Acceptors, Timothy D. Gustafson, Nancy C. Giles, Brian C. Holloway, J. Jesenovec, B. L. Dutton, M. D. Mccluskey, Larry E. Halliburton
Faculty Publications
Excerpt: Transition-metal ions (Ni, Cu, and Zn) in β-Ga2O3 crystals form deep acceptor levels in the lower half of the bandgap. In the present study, we characterize the Ni acceptors in a Czochralski-grown crystal and find that their (0/−) level is approximately 1.40 eV above the maximum of the valence band.
Optimizing Switching Of Non-Linear Properties With Hyperbolic Metamaterials, James A. Ethridge, John G. Jones, Manuel R. Ferdinandus, Michael J. Havrilla, Michael A. Marciniak
Optimizing Switching Of Non-Linear Properties With Hyperbolic Metamaterials, James A. Ethridge, John G. Jones, Manuel R. Ferdinandus, Michael J. Havrilla, Michael A. Marciniak
Faculty Publications
Hyperbolic metamaterials have been demonstrated to have special potential in their linear response, but the extent of their non-linear response has not been extensively modeled or measured. In this work, novel non-linear behavior of an ITO/SiO2 layered hyperbolic metamaterial is modeled and experimentally confirmed, specifically a change in the sign of the non-linear absorption with intensity. This behavior is tunable and can be achieved with a simple one-dimensional layered design. Fabrication was performed with physical vapor deposition, and measurements were conducted using the Z-scan technique. Potential applications include tunable optical switches, optical limiters, and tunable components of laser sources.
Oxygen Vacancies In Lib3O5 Crystals And Their Role In Nonlinear Absorption, Brian C. Holloway, Christopher A. Lenyk, Timothy D. Gustafson, Nancy C. Giles
Oxygen Vacancies In Lib3O5 Crystals And Their Role In Nonlinear Absorption, Brian C. Holloway, Christopher A. Lenyk, Timothy D. Gustafson, Nancy C. Giles
Faculty Publications
LiB3O5 (LBO) crystals are used to generate the second, third, and fourth harmonics of near-infrared solid-state lasers. At high power levels, the material’s performance is adversely affected by nonlinear absorption. We show that as-grown crystals contain oxygen and lithium vacancies. Transient absorption bands are formed when these intrinsic defects serve as traps for “free” electrons and holes created by x rays or by three- and four-photon absorption processes. Trapped electrons introduce a band near 300 nm and trapped holes produce bands in the 500-600 nm region. Electron paramagnetic resonance (EPR) is used to identify and characterize the …
Enabling Rapid Chemical Analysis Of Plutonium Alloys Via Machine Learning-Enhanced Atomic Spectroscopy Techniques, Ashwin P. Rao
Enabling Rapid Chemical Analysis Of Plutonium Alloys Via Machine Learning-Enhanced Atomic Spectroscopy Techniques, Ashwin P. Rao
Theses and Dissertations
Analytical atomic spectroscopy methods have the potential to provide solutions for rapid, high fidelity chemical analysis of plutonium alloys. Implementing these methods with advanced analytical techniques can help reduce the chemical analysis time needed for plutonium pit production, directly enabling the 80 pit-per-year by 2030 manufacturing goal outlined in the 2018 Nuclear Posture Review. Two commercial, handheld elemental analyzers were validated for potential in situ analysis of Pu. A handheld XRF device was able to detect gallium in a Pu surrogate matrix with a detection limit of 0.002 wt% and a mean error of 8%. A handheld LIBS device was …
Noncontact Liquid Crystalline Broadband Optoacoustic Sensors, Hengky Chandrahalim, Michael T. Dela Cruz
Noncontact Liquid Crystalline Broadband Optoacoustic Sensors, Hengky Chandrahalim, Michael T. Dela Cruz
AFIT Patents
An optoacoustic sensor includes a liquid crystal (LC) cell formed between top and bottom plates of transparent material. A transverse grating formed across the LC cell that forms an optical transmission bandgap. A CL is aligned to form a spring-like, tunable Bragg grating that is naturally responsive to external agitations providing a spectral transition regime, or edge, in the optical transmission bandgap of the transverse grating that respond to broadband acoustic waves. The optoacoustic sensor includes a narrowband light source that is oriented to transmit light through the top plate, the LC cell, and the bottom plate. The optoacoustic sensor …
Methods For Focal Plane Array Resolution Estimation Using Random Laser Speckle In Non-Paraxial Geometries, Phillip J. Plummer
Methods For Focal Plane Array Resolution Estimation Using Random Laser Speckle In Non-Paraxial Geometries, Phillip J. Plummer
Theses and Dissertations
The infrared (IR) imaging community has a need for direct IR detector evaluation due to the continued demand for small pixel pitch detectors, the emergence of strained-layer-super-lattice devices, and the associated lateral carrier diffusion issues. Conventional laser speckle-based modulation transfer function (MTF) estimation is dependent on Fresnel propagation and a wide-sense-stationary input random process, limiting the use of this approach for lambda (wavelength)-scale IR devices. This dissertation develops two alternative methodologies for speckle-based resolution evaluation of IR focal plane arrays (FPAs). Both techniques are formulated using Rayleigh-Sommerfield electric field propagation, making them valid in the non-paraxial geometries dictated for resolution …
Full Pattern Analysis And Comparison Of The Center Fed And Offset Fed Cassegrain Antennas With Large Focal Length To Diameter Ratios For High Power Microwave Transmission, Derek W. Mantzke
Theses and Dissertations
High power microwaves (HPM) have been a topic of research since the Cold War era. This paper will present a comparison between two Cassegrain-type antennas: the axially, or center fed, and the offset fed. Specifically, the 10 GHz operating frequency will be investigated with large focal length to diameter () ratios. Beam patterns which encompass the entire radiation pattern will be included for data validation and optimization. The simulations will follow a design of experiments factorial model to ensure all possible combinations of prescribed parameters are included, including an analysis of variance (ANOVA) study to find parameter influence on the …
Monolithically Integrated Microscale Pressure Sensor On An Optical Fiber Tip, Jeremiah C. Williams, Hengky Chandrahalim
Monolithically Integrated Microscale Pressure Sensor On An Optical Fiber Tip, Jeremiah C. Williams, Hengky Chandrahalim
AFIT Patents
A passive microscopic Fabry-Pérot Interferometer (FPI) pressure sensor includes an optical fiber and a three-dimensional microscopic optical enclosure. The three-dimensional microscopic optical enclosure includes tubular side walls having lateral pleated corrugations and attached to a cleaved tip of the optical fiber to receive a light signal. An optically reflecting end wall is distally engaged to the tubular side walls to enclose a trapped quantity of gas that longitudinally positions the optically reflecting end wall in relation to ambient air pressure, changing a distance traveled by a light signal reflected back through the optical fiber.
Hinged Temperature-Immune Self-Referencing Fabry–Pérot Cavity Sensors, Jeremiah C. Williams, Hengky Chandrahalim
Hinged Temperature-Immune Self-Referencing Fabry–Pérot Cavity Sensors, Jeremiah C. Williams, Hengky Chandrahalim
AFIT Patents
A passive microscopic Fabry-Pérot Interferometer (FPI) sensor includes a three-dimensional microscopic optical structure formed on a cleaved tip of the optical fighter using a two-photon polymerization process on a photosensitive polymer by a three-dimensional micromachining device. The three-dimensional microscopic optical structure having a hinged optical layer pivotally connected to a distal portion of a suspended structure. A reflective layer is deposited on a mirror surface of the hinged optical layer while in an open position. The hinged optical layer is subsequently positioned in the closed position to align the mirror surface to at least partially reflect a light signal back …
Aerial Radiation Detection Identification And Measurement System Detector Material Comparison Study, Benjamin C. Troxell, Kacey D. Mcgee, Christina L. Dugan
Aerial Radiation Detection Identification And Measurement System Detector Material Comparison Study, Benjamin C. Troxell, Kacey D. Mcgee, Christina L. Dugan
Faculty Publications
The 20th Chemical Biological Radiological Nuclear and Explosives Command (CBRNE) currently utilizes an airborne sodium iodide gamma and beta detection system to map radiation fields over large areas of interest. The 20th CBRNE explored emergent detector technologies utilizing two detection materials; thallium-activated cesium iodide and high purity germanium (HPGe). These detectors were simulated at various altitudes and compared to background measurements. The sodium iodide detector failed to provide isotopic discrimination at distance. The thallium-activated cesium iodide CsI(Tl) detector provided sufficient absolute efficiency and energy resolution to identify isotopics at distance. The HPGe detector provided the best energy resolution. However, current …
Method Of Making Hinged Self-Referencing Fabry–Pérot Cavity Sensors, Jeremiah C. Williams, Hengky Chandrahalim
Method Of Making Hinged Self-Referencing Fabry–Pérot Cavity Sensors, Jeremiah C. Williams, Hengky Chandrahalim
AFIT Patents
A method is provided for fabricating a passive optical sensor on a tip of an optical fiber. The method includes perpendicularly cleaving a tip of an optical fiber and mounting the tip of the optical fiber in a specimen holder of a photosensitive polymer three-dimensional micromachining machine. The method includes forming a three-dimensional microscopic optical structure within the photosensitive polymer that comprises a two cavity Fabry-Perot Interferometer (FPI) having a hinged optical layer that is pivotally coupled to a suspended structure. The method includes removing an uncured portion of the photosensitive polymer using a solvent. The method includes depositing a …
Thermo-Fluidic Transport Process In A Novel M-Shaped Cavity Packed With Non-Darcian Porous Medium And Hybrid Nanofluid: Application Of Artificial Neural Network (Ann), Dipak Kumar Mandal, Nirmalendu Biswas, Nirmal K. Manna, Dilip Kumar Gayen, Rama S. R. Gorla, Ali J. Chamkha
Thermo-Fluidic Transport Process In A Novel M-Shaped Cavity Packed With Non-Darcian Porous Medium And Hybrid Nanofluid: Application Of Artificial Neural Network (Ann), Dipak Kumar Mandal, Nirmalendu Biswas, Nirmal K. Manna, Dilip Kumar Gayen, Rama S. R. Gorla, Ali J. Chamkha
Faculty Publications
In this work, an attempt has been made to explore numerically the thermo-fluidic transport process in a novel M-shaped enclosure filled with permeable material along with Al2O3-Cu hybrid nanoparticles suspended in water under the influence of a horizontal magnetizing field. To exercise the influence of geometric parameters, a classical trapezoidal cavity is modified with an inverted triangle at the top to construct an M-shaped cavity. The cavity is heated isothermally from the bottom and cooled from the top, whereas the inclined sidewalls are insulated. The role of geometric parameters on the thermal performance is scrutinized thoroughly …
Formulation And Characterization Of Fast-Curing Plastic Scintillators With High-Z Loading, Theodore W. Stephens
Formulation And Characterization Of Fast-Curing Plastic Scintillators With High-Z Loading, Theodore W. Stephens
Theses and Dissertations
Development of novel fast-curing plastic scintillators is highly advantageous due to their potential to be manufactured via 3D printing. Several formulations were developed that exhibit enhanced photon sensitivity, producing modest but discernible photopeaks at an incident gamma energy of 122 keV. The photon sensitivity is achieved via bismuth high-Z loading; however, this practice typically results in diminished light yields. Subsequent formulations, which varied the photoinitiator concentration and curing time, demonstrated successful curing with sufficient plastic hardness, reduced purple discoloration, reduced heat buildup during curing, and resulted in less cracking during the curing process, all of which were correlated with lower …