Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Engineering

Mri Signal Intensity Differentiation Of Brainstem Encephalitis Induced By Enterovirus 71: A Classification Approach For Acute And Convalescence Stages, Hongwu Zeng, Wenxian Huang, Feiqiu Wen, Yonker Wang, Yungen Gan, Weibin Zeng, Ranran Chen, Yanxia He, Zaiyi Liu, Changhong Liang, Kelvin K. L. Wong Feb 2016

Mri Signal Intensity Differentiation Of Brainstem Encephalitis Induced By Enterovirus 71: A Classification Approach For Acute And Convalescence Stages, Hongwu Zeng, Wenxian Huang, Feiqiu Wen, Yonker Wang, Yungen Gan, Weibin Zeng, Ranran Chen, Yanxia He, Zaiyi Liu, Changhong Liang, Kelvin K. L. Wong

Radiology Faculty Publications

Background: The objective of this study is to assess standardized histograms of signal intensities of T1 signal and T2 signal on sagittal view without enhancement during (1) acute stage, and (2) convalescence stage of pediatric patients with Enterovirus 71 related brainstem encephalitis (BE), and with respect to (3) healthy normal.

Methods: Our subjects were hospitalized between March 2010 and October 2012, and underwent pre- and post-contrast MRI studies. The research question to be answered is whether the comparison of the MRI image intensity histograms and relevant statistical quantification can add new knowledge to the diagnosis of BE patients. So, both …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


Towards Omni-Tomography -- Grand Fusion Of Multiple Modalities For Simultaneous Interior Tomography, Ge Wang, Jie Zhang, Hao Gao, Victor Weir, Hengyong Yu, Wenxiang Cong, Xiaochen Xu, Haiou Shen, James Bennett, Mark Furth, Yue Wang, Michael Vannier Jun 2012

Towards Omni-Tomography -- Grand Fusion Of Multiple Modalities For Simultaneous Interior Tomography, Ge Wang, Jie Zhang, Hao Gao, Victor Weir, Hengyong Yu, Wenxiang Cong, Xiaochen Xu, Haiou Shen, James Bennett, Mark Furth, Yue Wang, Michael Vannier

Radiology Faculty Publications

We recently elevated interior tomography from its origin in computed tomography (CT) to a general tomographic principle, and proved its validity for other tomographic modalities including SPECT, MRI, and others. Here we propose "omni-tomography", a novel concept for the grand fusion of multiple tomographic modalities for simultaneous data acquisition in a region of interest (ROI). Omni-tomography can be instrumental when physiological processes under investigation are multi-dimensional, multi-scale, multi-temporal and multi-parametric. Both preclinical and clinical studies now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities. Over the past decade, two approaches have been used for multimodality …


A Fully Automated Non-External Marker 4d-Ct Sorting Algorithm Using A Serial Cine Scanning Protocol, Greg Carnes, Stewart Gaede, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee Apr 2009

A Fully Automated Non-External Marker 4d-Ct Sorting Algorithm Using A Serial Cine Scanning Protocol, Greg Carnes, Stewart Gaede, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee

Edward Yu

Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jan 2007

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Edward Yu

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


Dissociation Of Automatic And Strategic Lexical-Semantics: Functional Magnetic Resonance Imaging Evidence For Differing Roles Of Multiple Frontotemporal Regions, Brian T. Gold, David A. Balota, Sara J. Jones, David K. Powell, Charles D. Smith, Anders H. Andersen Jun 2006

Dissociation Of Automatic And Strategic Lexical-Semantics: Functional Magnetic Resonance Imaging Evidence For Differing Roles Of Multiple Frontotemporal Regions, Brian T. Gold, David A. Balota, Sara J. Jones, David K. Powell, Charles D. Smith, Anders H. Andersen

Neuroscience Faculty Publications

Behavioral research has demonstrated three major components of the lexical-semantic processing system: automatic activation of semantic representations, strategic retrieval of semantic representations, and inhibition of competitors. However, these component processes are inherently conflated in explicit lexical-semantic decision tasks typically used in functional magnetic resonance imaging (fMRI) research. Here, we combine the logic of behavioral priming studies and the neurophysiological phenomenon of fMRI priming to dissociate the neural bases of automatic and strategic lexical-semantic processes across a series of three studies. A single lexical decision task was used in all studies, with stimulus onset asynchrony or linguistic relationship between prime and …