Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 14 of 14

Full-Text Articles in Engineering

Atv Dynamics And Pediatric Rider Safety, James T. Auxier Ii Jan 2020

Atv Dynamics And Pediatric Rider Safety, James T. Auxier Ii

Theses and Dissertations--Biomedical Engineering

It has been observed through numerous academic and governmental agency studies that pediatric all-terrain vehicle ridership carries significant risk of injury and death. While no doubt valuable to safety, the post-hoc approach employed in these studies does little to explain the why and how behind the risk factors. Furthermore, there has been no prolonged, widespread, organized, and concerted effort to reconstruct and catalog the details and causes of the large (20,000+) number of ATV-related injuries that occur each year as has been done for road-based motor vehicle accidents. This dissertation takes the opposite approach from a meta-analysis and instead examines …


A Brain-Computer Interface For Closed-Loop Sensory Stimulation During Motor Training In Patients With Tetraplegia, Sarah Helen Thomas Jan 2019

A Brain-Computer Interface For Closed-Loop Sensory Stimulation During Motor Training In Patients With Tetraplegia, Sarah Helen Thomas

Theses and Dissertations--Biomedical Engineering

Normal movement execution requires proper coupling of motor and sensory activation. An increasing body of literature supports the idea that incorporation of sensory stimulation into motor rehabilitation practices increases its effectiveness. Paired associative stimulation (PAS) studies, in which afferent and efferent pathways are activated in tandem, have brought attention to the importance of well-timed stimulation rather than non-associative (i.e., open-loop) activation. In patients with tetraplegia resulting from spinal cord injury (SCI), varying degrees of upper limb function may remain and could be harnessed for rehabilitation. Incorporating associative sensory stimulation coupled with self-paced motor training would be a means for supplementing …


Calibrated Short Tr Recovery Mri For Rapid Measurement Of Brain-Blood Partition Coefficient And Correction Of Quantitative Cerebral Blood Flow, Scott William Thalman Jan 2019

Calibrated Short Tr Recovery Mri For Rapid Measurement Of Brain-Blood Partition Coefficient And Correction Of Quantitative Cerebral Blood Flow, Scott William Thalman

Theses and Dissertations--Biomedical Engineering

The high prevalence and mortality of cerebrovascular disease has led to the development of several methods to measure cerebral blood flow (CBF) in vivo. One of these, arterial spin labeling (ASL), is a quantitative magnetic resonance imaging (MRI) technique with the advantage that it is completely non-invasive. The quantification of CBF using ASL requires correction for a tissue specific parameter called the brain-blood partition coefficient (BBPC). Despite regional and inter-subject variability in BBPC, the current recommended implementation of ASL uses a constant assumed value of 0.9 mL/g for all regions of the brain, all subjects, and even all species.

The …


Adrenergic Stimulation In Acute Hyperglycemia: Effects On Cellular And Tissue Level Murine Cardiac Electrophysiology, Sridevi Thyagarajan Jan 2018

Adrenergic Stimulation In Acute Hyperglycemia: Effects On Cellular And Tissue Level Murine Cardiac Electrophysiology, Sridevi Thyagarajan

Theses and Dissertations--Biomedical Engineering

Cardiovascular complications associated with elevated levels of glucose in the blood (Hyperglycemia, HG) is a growing health concern. HG is known to be associated with a variety of cardiovascular morbidities including higher incidence of electrical disturbances. Although effects of chronic HG have been widely investigated, electrophysiological effects of acute hyperglycemia are relatively less known. Further, hyperglycemic effects on adrenergic response is not widely investigated. We used excised ventricular tissues from mice to record trans-membrane potentials during a variety of pacing protocols to investigate cellular/tissue level electrophysiological effects of acute hyperglycemia and adrenergic stimulation (1µM Isoproterenol, a β-adrenergic agonist). A custom …


Multimodal Noncontact Diffuse Optical Reflectance Imaging Of Blood Flow And Fluorescence Contrasts, Daniel Irwin Jan 2018

Multimodal Noncontact Diffuse Optical Reflectance Imaging Of Blood Flow And Fluorescence Contrasts, Daniel Irwin

Theses and Dissertations--Biomedical Engineering

In this study we design a succession of three increasingly adept diffuse optical devices towards the simultaneous 3D imaging of blood flow and fluorescence contrasts in relatively deep tissues. These metrics together can provide future insights into the relationship between blood flow distributions and fluorescent or fluorescently tagged agents. A noncontact diffuse correlation tomography (ncDCT) device was firstly developed to recover flow by mechanically scanning a lens-based apparatus across the sample. The novel flow reconstruction technique and measuring boundary curvature were advanced in tandem. The establishment of CCD camera detection with a high sampling density and flow recovery by speckle …


Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian Jan 2017

Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian

Theses and Dissertations--Biomedical Engineering

Management and control of the low back pain as an important health problem in the industrial societies necessitates to investigate how the risk of this disease is affected by aging. Since the abnormalities of the lumbopelvic kinematics are related to the existence or risk of low back injuries, the objective of this dissertation was set to find the age-related differences in lumbopelvic kinematics when performing basic trunk motions reaching to range of motion in different anatomical planes.

A cross-sectional study was designed where sixty asymptomatic individuals between 20–70 years old with no confounding health condition, no current or previous highly …


Validation, Optimization, And Image Processing Of Spiral Cine Dense Magnetic Resonance Imaging For The Quantification Of Left And Right Ventricular Mechanics, Gregory J. Wehner Jan 2017

Validation, Optimization, And Image Processing Of Spiral Cine Dense Magnetic Resonance Imaging For The Quantification Of Left And Right Ventricular Mechanics, Gregory J. Wehner

Theses and Dissertations--Biomedical Engineering

Recent evidence suggests that cardiac mechanics (e.g. cardiac strains) are better measures of heart function compared to common clinical metrics like ejection fraction. However, commonly-used parameters of cardiac mechanics remain limited to just a few measurements averaged over the whole left ventricle. We hypothesized that recent advances in cardiac magnetic resonance imaging (MRI) could be extended to provide measures of cardiac mechanics throughout the left and right ventricles (LV and RV, respectively).

Displacement Encoding with Stimulated Echoes (DENSE) is a cardiac MRI technique that has been validated for measuring LV mechanics at a magnetic field strength of 1.5 T but …


Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong Jan 2015

Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong

Theses and Dissertations--Biomedical Engineering

Chemo-radiation therapy is a principal modality for the treatment of head and neck cancers, and its efficacy depends on the interaction of tumor oxygen with free radicals. In this study, we adopted a novel hybrid diffuse optical instrument combining a commercial frequency-domain tissue oximeter (Imagent) and a custom-made diffuse correlation spectroscopy (DCS) flowmeter, which allowed for simultaneous measurements of tumor blood flow and blood oxygenation. Using this hybrid instrument we continually measured tumor hemodynamic responses to chemo-radiation therapy over the treatment period of 7 weeks. We also explored monitoring dynamic tumor hemodynamic changes during radiation delivery. Blood flow data analysis …


Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He Jan 2015

Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He

Theses and Dissertations--Biomedical Engineering

Since aggressive cancers are frequently hypermetabolic with angiogenic vessels, quantification of blood flow (BF) can be vital for cancer diagnosis. Our laboratory has developed a noncontact diffuse correlation tomography (ncDCT) system for 3-D imaging of BF distribution in deep tissues (up to centimeters). The ncDCT system employs two sets of optical lenses to project source and detector fibers respectively onto the tissue surface, and applies finite element framework to model light transportation in complex tissue geometries. This thesis reports our first step to adapt the ncDCT system for 3-D imaging of BF contrasts in human breast tumors. A commercial 3-D …


Bioerodible Calcium Sulfate Bone Grafting Substitutes With Tailored Drug Delivery Capabilities, Bryan R. Orellana Jan 2014

Bioerodible Calcium Sulfate Bone Grafting Substitutes With Tailored Drug Delivery Capabilities, Bryan R. Orellana

Theses and Dissertations--Biomedical Engineering

Bone regeneration or augmentation is often required prior to or concomitant with implant placement. With the limitations of many existing technologies, a biologically compatible synthetic bone grafting substitute that is osteogenic, bioerodible, and provides spacing-making functionality while acting as a drug delivery vehicle for bioactive molecules could provide an alternative to ‘gold standard’ techniques.

In the first part of this work, calcium sulfate (CS) space-making synthetic bone grafts with uniformly embedded poly(β-amino ester) (PBAE) biodegradable hydrogel particles was developed to allow controlled release of bioactive agents. The embedded gel particles’ influence on the physical and chemical characteristics of CS was …


Development Of An Eeg Brain-Machine Interface To Aid In Recovery Of Motor Function After Neurological Injury, Elizabeth Salmon Jan 2013

Development Of An Eeg Brain-Machine Interface To Aid In Recovery Of Motor Function After Neurological Injury, Elizabeth Salmon

Theses and Dissertations--Biomedical Engineering

Impaired motor function following neurological injury may be overcome through therapies that induce neuroplastic changes in the brain. Therapeutic methods include repetitive exercises that promote use-dependent plasticity (UDP), the benefit of which may be increased by first administering peripheral nerve stimulation (PNS) to activate afferent fibers, resulting in increased cortical excitability. We speculate that PNS delivered only in response to attempted movement would induce timing-dependent plasticity (TDP), a mechanism essential to normal motor learning. Here we develop a brain-machine interface (BMI) to detect movement intent and effort in healthy volunteers (n=5) from their electroencephalogram (EEG). This could be used in …


The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood Jan 2013

The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood

Theses and Dissertations--Biomedical Engineering

The effects of mechanical forces on endothelial cell function and behavior are well documented, but have not been fully characterized. Specifically, fluid pressure has been shown to elicit physical and chemical responses known to be involved in the initiation and progression of endothelial cell-mediated vascularization. Central to the process of vascularization is the formation of tube-like structures. This process—tubulogenesis—is essential to both the physiological and pathological growth of tissues. Given the known effects of pressure on endothelial cells and its ubiquitous presence in the vasculature, we investigated pressure as a magnitude-dependent parameter for the regulation of endothelial tubulogenic activity. To …


Noninvasive Near-Infrared Diffuse Optical Monitoring Of Cerebral Hemodynamics And Autoregulation, Ran Cheng Jan 2013

Noninvasive Near-Infrared Diffuse Optical Monitoring Of Cerebral Hemodynamics And Autoregulation, Ran Cheng

Theses and Dissertations--Biomedical Engineering

Many cerebral diseases are associated with abnormal cerebral hemodynamics and impaired cerebral autoregulation (CA). CA is a mechanism to maintain cerebral blood flow (CBF) stable when mean arterial pressure (MAP) fluctuates. Evaluating these abnormalities requires direct measurements of cerebral hemodynamics and MAP. Several near-infrared diffuse optical instruments have been developed in our laboratory for hemodynamic measurements including near-infrared spectroscopy (NIRS), diffuse correlation spectroscopy (DCS), hybrid NIRS/DCS, and dual-wavelength DCS flow-oximeter. We utilized these noninvasive technologies to quantify CBF and cerebral oxygenation in different populations under different physiological conditions/manipulations. A commercial finger plethysmograph was used to continuously monitor MAP. For investigating …


Noninvasive Assessment And Modeling Of Diabetic Cardiovascular Autonomic Neuropathy, Siqi Wang Jan 2012

Noninvasive Assessment And Modeling Of Diabetic Cardiovascular Autonomic Neuropathy, Siqi Wang

Theses and Dissertations--Biomedical Engineering

Noninvasive assessment of diabetic cardiovascular autonomic neuropathy (AN): Cardiac and vascular dysfunctions resulting from AN are complications of diabetes, often undiagnosed. Our objectives were to: 1) determine sympathetic and parasympathetic components of compromised blood pressure regulation in patients with polyneuropathy, and 2) rank noninvasive indexes for their sensitivity in diagnosing AN. Continuous 12-lead electrocardiography (ECG), blood pressure (BP), respiration, regional blood flow and bio-impedance were recorded from 12 able-bodied subjects (AB), 7 diabetics without (D0), 7 with possible (D1) and 8 with definite polyneuropathy (D2), during 10 minutes supine control, 30 minutes 70-degree head-up tilt and 5 minutes supine recovery. …