Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Engineering

Noncontact Speckle Contrast Diffuse Correlation Tomography Of Blood Flow Distributions In Tissues With Arbitrary Geometries, Siavash Mazdeyasna, Chong Huang, Mingjun Zhao, Nneamaka B. Agochukwu, Ahmed A. Bahrani, Lesley Wong, Guoqiang Yu Sep 2018

Noncontact Speckle Contrast Diffuse Correlation Tomography Of Blood Flow Distributions In Tissues With Arbitrary Geometries, Siavash Mazdeyasna, Chong Huang, Mingjun Zhao, Nneamaka B. Agochukwu, Ahmed A. Bahrani, Lesley Wong, Guoqiang Yu

Biomedical Engineering Faculty Publications

A noncontact electron multiplying charge-coupled-device (EMCCD)-based speckle contrast diffuse correlation tomography (scDCT) technology has been recently developed in our laboratory, allowing for noninvasive three-dimensional measurement of tissue blood flow distributions. One major remaining constraint in the scDCT is the assumption of a semi-infinite tissue volume with a flat surface, which affects the image reconstruction accuracy for tissues with irregular geometries. An advanced photometric stereo technique (PST) was integrated into the scDCT system to obtain the surface geometry in real time for image reconstruction. Computer simulations demonstrated that a priori knowledge of tissue surface geometry is crucial for precisely reconstructing the …


Comparison Of Left Ventricular Strains And Torsion Derived From Feature Tracking And Dense Cmr, Gregory J. Wehner, Linyuan Jing, Christopher M. Haggerty, Jonathan D. Suever, Jing Chen, Sean M. Hamlet, Jared A. Feindt, Walter Dimitri Mojsejenko, Mark A. Fogel, Brandon K. Fornwalt Sep 2018

Comparison Of Left Ventricular Strains And Torsion Derived From Feature Tracking And Dense Cmr, Gregory J. Wehner, Linyuan Jing, Christopher M. Haggerty, Jonathan D. Suever, Jing Chen, Sean M. Hamlet, Jared A. Feindt, Walter Dimitri Mojsejenko, Mark A. Fogel, Brandon K. Fornwalt

Biomedical Engineering Faculty Publications

Background: Cardiovascular magnetic resonance (CMR) feature tracking is increasingly used to quantify cardiac mechanics from cine CMR imaging, although validation against reference standard techniques has been limited. Furthermore, studies have suggested that commonly-derived metrics, such as peak global strain (reported in 63% of feature tracking studies), can be quantified using contours from just two frames – end-diastole (ED) and end-systole (ES) – without requiring tracking software. We hypothesized that mechanics derived from feature tracking would not agree with those derived from a reference standard (displacement-encoding with stimulated echoes (DENSE) imaging), and that peak strain from feature tracking would agree with …


Artificial Gravity As A Countermeasure To The Cardiovascular Deconditioning Of Spaceflight: Gender Perspectives, Joyce M. Evans, Charles F. Knapp, Nandu Goswami Jul 2018

Artificial Gravity As A Countermeasure To The Cardiovascular Deconditioning Of Spaceflight: Gender Perspectives, Joyce M. Evans, Charles F. Knapp, Nandu Goswami

Biomedical Engineering Faculty Publications

Space flight-induced physiological deconditioning resulting from decreased gravitational input, decreased plasma volume, and disruption of regulatory mechanisms is a significant problem in returning astronauts as well as in normal aging. Here we review effects of a promising countermeasure on cardiovascular systems of healthy men and women undergoing Earth-based models of space-flight. This countermeasure is produced by a centrifuge and called artificial gravity (AG). Numerous studies have determined that AG improves orthostatic tolerance (as assessed by various protocols) of healthy ambulatory men, of men deconditioned by bed rest or by immersion (both wet and dry) and, in one case, following spaceflight. …


Cortical Statistical Correlation Tomography Of Eeg Resting State Networks, Chuang Li, Han Yuan, Guofa Shou, Yoon-Hee Cha, Sridhar Sunderam, Walter Besio, Lei Ding May 2018

Cortical Statistical Correlation Tomography Of Eeg Resting State Networks, Chuang Li, Han Yuan, Guofa Shou, Yoon-Hee Cha, Sridhar Sunderam, Walter Besio, Lei Ding

Biomedical Engineering Faculty Publications

Resting state networks (RSNs) have been found in human brains during awake resting states. RSNs are composed of spatially distributed regions in which spontaneous activity fluctuations are temporally and dynamically correlated. A new computational framework for reconstructing RSNs with human EEG data has been developed in the present study. The proposed framework utilizes independent component analysis (ICA) on short-time Fourier transformed inverse source maps imaged from EEG data and statistical correlation analysis to generate cortical tomography of electrophysiological RSNs. The proposed framework was evaluated on three sets of resting-state EEG data obtained in the comparison of two conditions: (1) healthy …


Muscle Activity During Maximal Isometric Forearm Rotation Using A Power Grip, Joseph Scott Bader, Michael R. Boland, Desney Greybe, Arthur J. Nitz, Timothy L. Uhl, David A. Pienkowski Feb 2018

Muscle Activity During Maximal Isometric Forearm Rotation Using A Power Grip, Joseph Scott Bader, Michael R. Boland, Desney Greybe, Arthur J. Nitz, Timothy L. Uhl, David A. Pienkowski

Biomedical Engineering Faculty Publications

This study aimed to provide quantitative activation data for muscles of the forearm during pronation and supination while using a power grip. Electromyographic data was collected from 15 forearm muscles in 11 subjects while they performed maximal isometric pronating and supinating efforts in nine positions of forearm rotation. Biceps brachii was the only muscle with substantial activation in only one effort direction. It was significantly more active when supinating (µ = 52.1%, SD = 17.5%) than pronating (µ = 5.1%, SD = 4.8%, p < .001). All other muscles showed considerable muscle activity during both pronation and supination. Brachioradialis, flexor carpi radialis, palmaris longus, pronator quadratus and pronator teres were significantly more active when pronating the forearm. Abductor pollicis longus and biceps brachii were significantly more active when supinating. This data highlights the importance of including muscles additional to the primary forearm rotators in a biomechanical analysis of forearm rotation. Doing so will further our understanding of forearm function and lead to the improved treatment of forearm fractures, trauma-induced muscle dysfunction and joint replacements.