Electroporation Safety Factor Of 300 Nanosecond And 10 Millisecond Defibrillation In Langendorff-Perfused Rabbit Hearts, Johanna U. Neuber, Andrei G. Pakhomov, Christian W. Zemlin
Electroporation Safety Factor Of 300 Nanosecond And 10 Millisecond Defibrillation In Langendorff-Perfused Rabbit Hearts, Johanna U. Neuber, Andrei G. Pakhomov, Christian W. Zemlin
Bioelectrics Publications
Aims
Recently, a new defibrillation modality using nanosecond pulses was shown to be effective at much lower energies than conventional 10 millisecond monophasic shocks in ex vivo experiments. Here we compare the safety factors of 300 nanosecond and 10 millisecond shocks to assess the safety of nanosecond defibrillation.
Methods and results
The safety factor, i.e. the ratio of median effective doses (ED50) for electroporative damage and defibrillation, was assessed for nanosecond and conventional (millisecond) defibrillation shocks in Langendorff-perfused New Zealand white rabbit hearts. In order to allow for multiple shock applications in a single heart, a pair of needle electrodes …
Self-Consistent Analyses For Potential Conduction Block In Nerves By An Ultrashort High-Intensity Electric Pulse, R. P. Joshi, A. Mishra, Q. Hu, K. H. Schoenbach, A. Pakhomov
Self-Consistent Analyses For Potential Conduction Block In Nerves By An Ultrashort High-Intensity Electric Pulse, R. P. Joshi, A. Mishra, Q. Hu, K. H. Schoenbach, A. Pakhomov
Bioelectrics Publications
Simulation studies are presented that probe the possibility of using high-field (>100kV ∕ cm), short-duration (∼50ns) electrical pulses for nonthermal and reversible cessation of biological electrical signaling pathways. This would have obvious applications in neurophysiology, clinical research, neuromuscular stimulation therapies, and even nonlethal bioweapons development. The concept is based on the creation of a sufficiently high density of pores on the nerve membrane by an electric pulse. This modulates membrane conductance and presents an effective "electrical short" to an incident voltage wave traveling across a nerve. Net blocking of action potential propagation can then result. A continuum approach based …