Recent Progress In Microrna Detection Using Integrated Electric Fields And Optical Detection Methods, Logeeshan Velmanickam, Dharmakeerthi Nawarathna Jan 2024

Recent Progress In Microrna Detection Using Integrated Electric Fields And Optical Detection Methods, Logeeshan Velmanickam, Dharmakeerthi Nawarathna

Electrical & Computer Engineering Faculty Publications

Low-cost, highly-sensitivity, and minimally invasive tests for the detection and monitoring of life-threatening diseases and disorders can reduce the worldwide disease burden. Despite a number of interdisciplinary research efforts, there are still challenges remaining to be addressed, so clinically significant amounts of relevant biomarkers in body fluids can be detected with low assay cost, high sensitivity, and speed at point-of-care settings. Although the conventional proteomic technologies have shown promise, their ability to detect all levels of disease progression from early to advanced stages is limited to a limited number of diseases. One potential avenue for early diagnosis is microRNA (miRNA). …


Plasma-Treated Solutions (Pts) In Cancer Therapy, Hiromasa Tanaka, Sander Bekeschus, Dayun Yan, Masaru Hori, Michael Keidar, Mounir Laroussi Jan 2021

Plasma-Treated Solutions (Pts) In Cancer Therapy, Hiromasa Tanaka, Sander Bekeschus, Dayun Yan, Masaru Hori, Michael Keidar, Mounir Laroussi

Electrical & Computer Engineering Faculty Publications

Cold physical plasma is a partially ionized gas generating various reactive oxygen and nitrogen species (ROS/RNS) simultaneously. ROS/RNS have therapeutic effects when applied to cells and tissues either directly from the plasma or via exposure to solutions that have been treated beforehand using plasma processes. This review addresses the challenges and opportunities of plasma-treated solutions (PTSs) for cancer treatment. These PTSs include plasma-treated cell culture media in experimental research as well as clinically approved solutions such as saline and Ringer’s lactate, which, in principle, already qualify for testing in therapeutic settings. Several types of cancers were found to succumb to …


Monopolar Gene Electrotransfer Enhances Plasmid Dna Delivery To Skin, Anna Bulysheva, Loree Heller, Michael Francis, Frency Varghese, Carly Boye, Richard Heller Jan 2021

Monopolar Gene Electrotransfer Enhances Plasmid Dna Delivery To Skin, Anna Bulysheva, Loree Heller, Michael Francis, Frency Varghese, Carly Boye, Richard Heller

Electrical & Computer Engineering Faculty Publications

A novel monopolar electroporation system and methodologies were developed for in vivo electroporation intended for potential clinical applications such as gene therapy. We hypothesized that an asymmetric anode/cathode electrode applicator geometry could produce favorable electric fields for electroporation, without the typical drawback associated with traditional needle and parallel plate geometries. Three monopolar electrode applicator prototypes were built and tested for gene delivery of reporter genes to the skin in a guinea pig model. Gene expression was evaluated in terms of kinetics over time and expression distribution within the treatment site. Different pulsing parameters, including pulse amplitude, pulse duration, and pulse …


Estimating Cognitive Workload In An Interactive Virtual Reality Environment Using Eeg, Christoph Tremmel, Christain Herff, Tetsuya Sato, Krzysztof Rechowicz, Yusuke Yamani, Dean J. Krusienski Nov 2019

Estimating Cognitive Workload In An Interactive Virtual Reality Environment Using Eeg, Christoph Tremmel, Christain Herff, Tetsuya Sato, Krzysztof Rechowicz, Yusuke Yamani, Dean J. Krusienski

Electrical & Computer Engineering Faculty Publications

With the recent surge of affordable, high-performance virtual reality (VR) headsets, there is unlimited potential for applications ranging from education, to training, to entertainment, to fitness and beyond. As these interfaces continue to evolve, passive user-state monitoring can play a key role in expanding the immersive VR experience, and tracking activity for user well-being. By recording physiological signals such as the electroencephalogram (EEG) during use of a VR device, the user's interactions in the virtual environment could be adapted in real-time based on the user's cognitive state. Current VR headsets provide a logical, convenient, and unobtrusive framework for mounting EEG …


Plasma Medicine: A Brief Introduction, Mounir Laroussi Jan 2018

Plasma Medicine: A Brief Introduction, Mounir Laroussi

Electrical & Computer Engineering Faculty Publications

This mini review is to introduce the readers of Plasma to the field of plasma medicine. This is a multidisciplinary field of research at the intersection of physics, engineering, biology and medicine. Plasma medicine is only about two decades old, but the research community active in this emerging field has grown tremendously in the last few years. Today, research is being conducted on a number of applications including wound healing and cancer treatment. Although a lot of knowledge has been created and our understanding of the fundamental mechanisms that play important roles in the interaction between low temperature plasma and …


Empirical Models Of Scalp-Eeg Responses Using Non-Concurrent Intracranial Responses, Komalpreet Kaur, Jerry J. Shih, Dean J. Krusienski Jan 2014

Empirical Models Of Scalp-Eeg Responses Using Non-Concurrent Intracranial Responses, Komalpreet Kaur, Jerry J. Shih, Dean J. Krusienski

Electrical & Computer Engineering Faculty Publications

Objective- This study presents inter-subject models of scalp-recorded electroencephalographic (sEEG) event-related potentials (ERPs) using intracranially recorded ERPs from electrocorticography and stereotactic depth electrodes in the hippocampus, generally termed as intracranial EEG (iEEG).

Approach- The participants were six patients with medically-intractable epilepsy that underwent temporary placement of intracranial electrode arrays to localize seizure foci. Participants performed one experimental session using a brain-computer interface matrix spelling paradigm controlled by sEEG prior to the iEEG electrode implantation, and one or more identical sessions controlled by iEEG after implantation. All participants were able to achieve excellent spelling accuracy using sEEG, four of the participants …


Signals From Intraventricular Depth Electrodes Can Control A Brain-Computer Interface, Jerry J. Shih, Dean J. Krusienski Jan 2012

Signals From Intraventricular Depth Electrodes Can Control A Brain-Computer Interface, Jerry J. Shih, Dean J. Krusienski

Electrical & Computer Engineering Faculty Publications

A Brain-Computer Interface (BCI) is a device that enables severely disabled people to communicate and interact with their environments using their brain waves. Most research investigating BCI in humans have used scalp-recorded electroencephalography (EEG). We have recently demonstrated that signals from intracranial electrocorticography (ECoG) and stereotactic depth electrodes (SDE) in the hippocampus can be used to control a BCI P300 Speller paradigm. We report a case in which stereotactic depth electrodes positioned in the ventricle were able to obtain viable signals for a BCI. Our results demonstrate that event-related potentials from intraventricular electrodes can be used to reliably control the …


Individualized Cognitive Modeling For Close-Loop Task Mitigation, Guangfan Zhang, Roger Xu, Wei Wang, Jiang Li, Tom Schnell, Mike Keller, Thomas E. Pinelli (Ed.) Jan 2010

Individualized Cognitive Modeling For Close-Loop Task Mitigation, Guangfan Zhang, Roger Xu, Wei Wang, Jiang Li, Tom Schnell, Mike Keller, Thomas E. Pinelli (Ed.)

Electrical & Computer Engineering Faculty Publications

An accurate real-time operator functional state assessment makes it possible to perform task management, minimize risks, and improve mission performance. In this paper, we discuss the development of an individualized operator functional state assessment model that identifies states likely leading to operational errors. To address large individual variations, we use two different approaches to build a model for each individual using its data as well as data from subjects with similar responses. If a subject's response is similar to that of the individual of interest in a specific functional state, all the training data from this subject will be used …


Destruction Of Α -Synuclein Based Amyloid Fibrils By A Low Temperature Plasma Jet, Erdinc Karakas, Agatha Munyanyi, Lesley Greene, Mounir Laroussi Jan 2010

Destruction Of Α -Synuclein Based Amyloid Fibrils By A Low Temperature Plasma Jet, Erdinc Karakas, Agatha Munyanyi, Lesley Greene, Mounir Laroussi

Electrical & Computer Engineering Faculty Publications

Amyloid fibrils are ordered beta-sheet aggregates that are associated with a number of neurodegenerative diseases such as Alzheimer and Parkinson. At present, there is no cure for these progressive and debilitating diseases. Here we report initial studies that indicate that low temperature atmospheric pressure plasma can break amyloid fibrils into smaller units in vitro. The plasma was generated by the plasma pencil, a device capable of emitting a long, low temperature plasma plume/jet. This avenue of research may facilitate the development of a plasma-based medical treatment.


A Noninvasive Test For Vesico-Ureteric Reflux In Children, R. A. Mevorach, B. Cilento, S. Zahorian, C. Badgett, R. Walker, A. Atala, S. Iannello, M. Meyer Jan 2001

A Noninvasive Test For Vesico-Ureteric Reflux In Children, R. A. Mevorach, B. Cilento, S. Zahorian, C. Badgett, R. Walker, A. Atala, S. Iannello, M. Meyer

Electrical & Computer Engineering Faculty Publications

Objective To report the development and testing of a device for the noninvasive diagnosis of vesico‐ureteric reflux (VUR) which avoids the need for urethral catheterization (currently required to reliably determine the presence of VUR), and which thus avoids the anxiety of parents and patients that causes many families to refuse such evaluation.

Patients and methods Fifty‐four children (49 girls and five boys, mean age 7.2 years, range 4–14) previously evaluated as having VUR volunteered to participate; no child was symptomatic at the time of the study. Refluxing units were known to be present by voiding cysto‐urethrography (within 1 year, mean …