Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering

Electronic Theses and Dissertations

2021

Daniel Felix Ritchie School of Engineering and Computer Science

Articles 1 - 6 of 6

Full-Text Articles in Engineering

Design Of Lower Legs Of Mithra, A High-Performance Backdrivable Humanoid Robot, Drake Taylor Jan 2021

Design Of Lower Legs Of Mithra, A High-Performance Backdrivable Humanoid Robot, Drake Taylor

Electronic Theses and Dissertations

This thesis presents the design of the knee and ankle of Mithra, a new humanoid robot that aims to be an energy-efficient and highly agile machine. Mithra makes use of new optimization metrics for legged robots to develop a system capable of mimicking human movement. A series of low-impedance, high-torque actuator systems were developed with the goal of creating lightweight, powerful, and robust motion. The structure of Mithra's legs mimics the human structure in leg segment length and weight proportions. Detailed design and analysis were conducted in order to allow Mithra to be a robust and maintainable system. Mithra will …


Monitoring Of Overhead Polymer Core Composite Conductors Under Excessive Mechanical Loads Using Fiber Bragg Grating Sensors, Daniel H. Waters Jan 2021

Monitoring Of Overhead Polymer Core Composite Conductors Under Excessive Mechanical Loads Using Fiber Bragg Grating Sensors, Daniel H. Waters

Electronic Theses and Dissertations

This combined experimental and numerical study addresses mechanical effects associated with static and dynamic loading of novel High Temperature Low Sag (HTLS) transmission line polymer core composite conductors. The developed methodology was successfully applied to ACCC® to explain the complex failure mechanisms associated with combined bending and tension loading. Furthermore, the use of Fiber Bragg Grating (FBG) sensors was investigated for the first time to monitor the ACCC® design during installation and in-service.

Transverse low-velocity impacts to the ACCC® conductor having either free or constrained end conditions and large axial tensile loads were performed. It was identified that the most …


Broadening The Capability Of Kinetics Analysis In Biomechanics, Nicholas Nelson Jan 2021

Broadening The Capability Of Kinetics Analysis In Biomechanics, Nicholas Nelson

Electronic Theses and Dissertations

Two studies are discussed in this manuscript each preceded by a literature review of the topic. The first review and study explore agility movements and the effect that alternative upper designs in shoes might have on ground reaction force measures of performance. The second review and study evaluate methods of predicting ground reaction forces without the use of a force platform. A method of using effective forces and ways of improving its accuracy are evaluated in depth.


Tibial Strains And Tray-Bone Micromotions After Total Knee Arthroplasty: Computational Studies Evaluating The Tibial Fixation, Huizhou Yang Jan 2021

Tibial Strains And Tray-Bone Micromotions After Total Knee Arthroplasty: Computational Studies Evaluating The Tibial Fixation, Huizhou Yang

Electronic Theses and Dissertations

Cemented and cementless fixation in total knee arthroplasty (TKA) have been successfully used for decades. As the number of younger and more active patients treated with TKA continues to increase, long-term implant survivorship is of increasing importance. One of the most common complications and hence the reason for revision is mechanical loosening (23.1% of all revised TKA). The loosening mechanisms have been proposed for different fixation types. For cemented fixation, bone remodeling after surgery is regulated by the changes in strain energy density (SED). The recruitment of osteoclasts and osteoblasts is controlled by SED-related signals. Insufficient stimuli can promote bone …


Development Of Triangular And Tetrahedral Finite Elements For Solutions To Thermoelastic Instabilities Using Hotspotter, Cortney Samuel Leneave Jan 2021

Development Of Triangular And Tetrahedral Finite Elements For Solutions To Thermoelastic Instabilities Using Hotspotter, Cortney Samuel Leneave

Electronic Theses and Dissertations

The objective of the work presented in this thesis is to develop first-order triangular and tetrahedral elements for solutions to Thermoelastic Instabilities (TEI) regarding sliding friction systems in Hotspotter.

Hotspotter software uses a finite element method and an eigenvalue method and is an important tool because currently no other commercial software exists which solves the TEI problem for critical velocities and wave numbers of a system. Hotspotter currently uses quadrilateral and hexahedral elements for two and three dimensional analysis, respectively. Typically, tri and tet elements are used in industry when doing static and dynamic stress analysis. Therefore, the Hotspotter user …


An Accuracy And Precision Analysis Of The Velys™ Robotic Assisted Solution For Total Knee Arthroplasty, Gary Doan Jan 2021

An Accuracy And Precision Analysis Of The Velys™ Robotic Assisted Solution For Total Knee Arthroplasty, Gary Doan

Electronic Theses and Dissertations

Total knee arthroplasty (TKA) is a procedure where the arthritic surfaces of the knee is removed and replaced with a combination of metal and polymer implants that recreates the joint line to restore function and quality of life. Implant alignment is important in the success of a TKA. Modern day conventional instrumentation can be cumbersome in the operating room and can be inaccurate when resecting bone and aligning implants. Patients with large errors in resections and implant orientation are more prone to experience mechanical failures with their TKA. Mechanical failures in primary TKA require revision surgeries which can lead to …