Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 3 of 3
Full-Text Articles in Engineering
In Vivo Data Capture Using Hssr For Calibration Of Computational Models, Thor Erik Andreassen
In Vivo Data Capture Using Hssr For Calibration Of Computational Models, Thor Erik Andreassen
Electronic Theses and Dissertations
Computational modeling is a vital tool for understanding and evaluating healthy and unhealthy function of the musculoskeletal aspects of the human body. However, the accuracy of the musculoskeletal models depends significantly on the accuracy of the input data used to calibrate various behavioral parameters of the model. To date, most computational models have been built using generic in vitro data, mostly because of a lack of accurate and meaningful datasets from in vivo testing. The next major step in computational modeling is to create subject-specific computational models using calibration data taken from in vivo testing. The overall goal was to …
The Effects And Analysis Of Implant Type And Surgical Approach In Total Hip Arthroplasty Dislocation Resistance, Brittany Marshall
The Effects And Analysis Of Implant Type And Surgical Approach In Total Hip Arthroplasty Dislocation Resistance, Brittany Marshall
Electronic Theses and Dissertations
Total hip arthroplasty (THA) is one of the most successful orthopaedic surgeries performed, in which the hip joint is reconstructed to decrease pain and to improve the functionality to the joint. Although these surgeries are very successful, there still remain areas for improvement, such as failures due to instability and dislocation of the implanted joint. The purpose of this thesis is to investigate the effect of surgical entrance approach on dislocation, the effect of implant type, and the effect of capsule repair and closure. The need to quantify the resistance to dislocation is important in understanding the effect that each …
Effects On Initial Fixation Of Cementless Tibial Trays In Total Knee Arthroplasty, Brooke Fritts Thompson
Effects On Initial Fixation Of Cementless Tibial Trays In Total Knee Arthroplasty, Brooke Fritts Thompson
Electronic Theses and Dissertations
Bone mineral density (BMD), among other factors, largely effect the initial stability of the cementless tibial tray component in a total knee replacement (TKR), where increased motion at the tray-bone interface hinders bony ingrowth. With a lack of bony ingrowth, the cementless implant will not experience long-term success. Understanding which factors influence initial stability yields insight into surgical technique considerations and help inform a surgeon’s implant choice. The objective of this study was to evaluate factors influencing the initial stability of cementless tibial trays using a 6-degree of freedom (6-DOF) robotic joint simulator, the AMTI VIVO, and combined loading scenarios …