Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Oxidase-Coupled Amperometric Glucose And Lactate Sensors With Integrated Electrochemical Actuation System, Jongwon Park, Chang-Soo Kim, Minsu Choi Aug 2006

Oxidase-Coupled Amperometric Glucose And Lactate Sensors With Integrated Electrochemical Actuation System, Jongwon Park, Chang-Soo Kim, Minsu Choi

Electrical and Computer Engineering Faculty Research & Creative Works

Unpredictable baseline drift and sensitivity degradation during continuous use are two of the most significant problems of biosensors including the amperometric glucose and lactate sensors. Therefore, the capability of on-demand in situ calibration/diagnosis of biochemical sensors is indispensable for reliable long-term monitoring with minimum attendance. Another limitation of oxidase enzyme-based biosensors is the dependence of enzyme activity on the background oxygen concentration in sample solution. In order to address these issues, the electrolytic generation of oxygen and hydrogen bubbles were utilized 1) to overcome the background oxygen dependence of glucose and lactate sensors and 2) to demonstrate the feasibility of …


Automated Oxidase-Coupled Amperometric Microsensor With Integrated Electrochemical Actuation System For Continuous Sensing Of Saccharoids, Yadunandana Yellambalase, Jongwon Park, Chang-Soo Kim, Minsu Choi, Nohpill Park, Fabrizio Lombardi Apr 2006

Automated Oxidase-Coupled Amperometric Microsensor With Integrated Electrochemical Actuation System For Continuous Sensing Of Saccharoids, Yadunandana Yellambalase, Jongwon Park, Chang-Soo Kim, Minsu Choi, Nohpill Park, Fabrizio Lombardi

Electrical and Computer Engineering Faculty Research & Creative Works

Recent developments for biosensors have been mainly focused on miniaturization and exploratory use of new materials. It should be emphasized that the absence of a novel "in-situ self-calibration/diagnosis technique" that is not connected to an external apparatus is a key obstacle to the realization of a biosensor for continuous use with minimum attendance. To address this deficiency, a novel needle-type biosensor system with fully automated operations is being developed, in which a novel oxidase-coupled amperometric sensor with oxygen depleting/generating actuator is interfaced with an electrochemical instrument and a perfusion system. Labview virtual instrument has been also developed to oversee the …


Design And Implementation Of A Storage Management Method For Content Distribution, Chang-Soo Kim, Yu-Hyeon Bak, Sang-Min Woo, Won-Jae Lee, Nunm-Ok Gee, Hag-Young Kim Jan 2006

Design And Implementation Of A Storage Management Method For Content Distribution, Chang-Soo Kim, Yu-Hyeon Bak, Sang-Min Woo, Won-Jae Lee, Nunm-Ok Gee, Hag-Young Kim

Electrical and Computer Engineering Faculty Research & Creative Works

The SMART system is a special purpose server developed by ETRI and designed for efficient streaming services over high speed networks. The SMART server has one or more special purpose NS (Network-Storage) card. The NS card has several disks that store multimedia contents. However all of the multimedia contents to be serviced cannot be stored at the server. In this paper, we will describe the storage management mechanism in design and implementation aspects. With this storage management mechanism, the SMART server can provide effectiveness in managing storage and distributing some contents from a source station to streaming service servers.