Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Engineering

Power Distribution:Protection Analysis, Avneet S. Samra Dec 2016

Power Distribution:Protection Analysis, Avneet S. Samra

Electrical Engineering

The objective of this project is to build a radial distribution system that operates on a lower voltage. The system consists of a transmission line protected by a SEL-351 Relay, a three- phase transformer protected by a SEL-587 Relay, and a three-phase induction motor protected by a Cooper Form 6 Controller. The SEL-351, SEL-587, and the Cooper Form 6 Controller are microprocessor-based relays that are used to provide protection under faulted conditions. When a fault is detected in the system, the closest upstream relay sends a trip signal to its assigned local breaker. The SEL-351 provides overcurrent protection for the …


Solid State Protective Device Topological Trade-Offs For Mvdc Systems, Vikas Singh Dec 2016

Solid State Protective Device Topological Trade-Offs For Mvdc Systems, Vikas Singh

Theses and Dissertations

Presently accepted approaches to protection are “Unit-Based” which means the power converter(s) feeding the bus coordinate with no-load electromechanical switches to isolate faulted portions of the bus. However, “Breaker-Based” approaches, which rely upon solid state circuit breakers for fault mitigation can result in higher reliability of power and potentially higher survivability. The inherent speed of operation of solid state protective devices will also play a role in fault isolation, hence reducing stress level on all system components. A comparison study is performed of protective device topologies that are suitable for shipboard distribution systems rated between 4kVdc and 20kVdc from the …


Transformer And Motor Protection Scheme, Bijan Vakilifathi Jun 2016

Transformer And Motor Protection Scheme, Bijan Vakilifathi

Electrical Engineering

No abstract provided.


Integration Of Sel Relays To Provide Motor, Transmission Line, And Transformer Protection, Christopher Ewing, Bryce Keefer Jun 2016

Integration Of Sel Relays To Provide Motor, Transmission Line, And Transformer Protection, Christopher Ewing, Bryce Keefer

Electrical Engineering

The objective of this project is to familiarize the performers with the principles of operation of the Schweitzer Engineering Laboratories (SEL) protective relays in both normal and fault conditions. The SEL-587, SEL-311L and SEL-710 microprocessor-based relays are used to provide protection for a system composed of transformers, simulated transmission lines and a 3-phase induction motor. Each of these relays provides protection by sending a trip signal to local breakers upon sensing a fault condition. The SEL-587 provides overcurrent and differential protection for a 3-phase transformer, while the SEL-311L provides differential and distance protection for a transmission line, and negative sequence. …


Hybrid Energy Storage Implementation In Dc And Ac Power System For Efficiency, Power Quality And Reliability Improvements, Mustafa Farhadi Mar 2016

Hybrid Energy Storage Implementation In Dc And Ac Power System For Efficiency, Power Quality And Reliability Improvements, Mustafa Farhadi

FIU Electronic Theses and Dissertations

Battery storage devices have been widely utilized for different applications. However, for high power applications, battery storage systems come with several challenges, such as the thermal issue, low power density, low life span and high cost. Compared with batteries, supercapacitors have a lower energy density but their power density is very high, and they offer higher cyclic life and efficiency even during fast charge and discharge processes. In this dissertation, new techniques for the control and energy management of the hybrid battery-supercapacitor storage system are developed to improve the performance of the system in terms of efficiency, power quality and …


Grid-Connected Induction Generator Interturn Fault Analysis Using A Pca-Ann-Based Algorithm, Haydar Bayar, Ümi̇t Kemaletti̇n Terzi̇ Jan 2016

Grid-Connected Induction Generator Interturn Fault Analysis Using A Pca-Ann-Based Algorithm, Haydar Bayar, Ümi̇t Kemaletti̇n Terzi̇

Turkish Journal of Electrical Engineering and Computer Sciences

It is difficult for short circuits among the internal windings of one phase in electrical machines to be determined in a reliable and speedy manner. The failure currents that occur, especially in short circuits with a few windings, are at such low levels that they cannot be determined by relay systems. This results in growing faults and damage. In this study, we designed a model that can define winding failures successfully at very small levels by using the PCA and ANN algorithms. We tested the real-time faults and measured the system performance with the installed test rig. The developed protection …