Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Electrical and Computer Engineering

Electrical and Computer Engineering Faculty Research and Publications

2004

Rotors

Articles 1 - 2 of 2

Full-Text Articles in Engineering

Condition Monitoring Of Squirrel-Cage Induction Motors Fed By Pwm-Based Drives Using A Parameter Estimation Approach, Behrooz Mirafzal, F. Fateh, Chia-Chou Yeh, Richard J. Povinelli, Nabeel Demerdash Nov 2004

Condition Monitoring Of Squirrel-Cage Induction Motors Fed By Pwm-Based Drives Using A Parameter Estimation Approach, Behrooz Mirafzal, F. Fateh, Chia-Chou Yeh, Richard J. Povinelli, Nabeel Demerdash

Electrical and Computer Engineering Faculty Research and Publications

Abstract:

A rotor condition monitoring technique is presented in this paper based on a parameter estimation approach. In this technique, the stator currents, voltages and motor speed are used as the input signals, where the outputs will be the rotor's inductance, resistance and consequently rotor time constant. This approach is verified by simulation of two different induction motor cases. These simulations are buttressed by experimental data obtained for a 2-hp induction motor in the case of healthy as well as one, three and five rotor bar breakages. In these tests, the induction motor was energized from a PWM-based drive, in …


Induction Machine Broken-Bar Fault Diagnosis Using The Rotor Magnetic Field Space-Vector Orientation, Behrooz Mirafzal, Nabeel Demerdash Mar 2004

Induction Machine Broken-Bar Fault Diagnosis Using The Rotor Magnetic Field Space-Vector Orientation, Behrooz Mirafzal, Nabeel Demerdash

Electrical and Computer Engineering Faculty Research and Publications

A new technique based on rotor magnetic field space vector orientation is presented to diagnose broken-bar faults in induction machines operating at steady state. In this technique, stator currents and voltages are used as inputs to compute and subsequently observe the rotor magnetic field orientation, which has a more significant "swing-like" pendulous oscillation in case of broken-bar faults than in healthy operation. It will be shown here that the range of this "pendulous oscillation" is a function of the number of broken bars. Also in this technique, it was found that an inter-turn shorted stator-winding fault, which exhibits similar pendulous …