Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Electrical and Computer Engineering

Old Dominion University

Bioelectrics Publications

Chemical elements

Articles 1 - 15 of 15

Full-Text Articles in Engineering

Quantifying The Concentration And Penetration Depth Of Long-Lived Rons In Plasma Activated Water By Uv Absorption Spectroscopy, Zhijie Liu, Chunxi Zhou, Dingxin Liu, Tongtong He, Li Guo, Dehui Xu, Michael G. Kong Jan 2019

Quantifying The Concentration And Penetration Depth Of Long-Lived Rons In Plasma Activated Water By Uv Absorption Spectroscopy, Zhijie Liu, Chunxi Zhou, Dingxin Liu, Tongtong He, Li Guo, Dehui Xu, Michael G. Kong

Bioelectrics Publications

Reactive oxygen and reactive nitrogen species (RONS) are believed to play a key role in biomedical applications, which means that RONS must reach the target tissue to produce a therapeutic effect. Existing methods (electron spin spectrometry and microplate reading) to determine the RONS concentration are not suitable for experimental real-time measurements because they require adding an indicating reagent to the plasma-treated medium, which may alter the chemical composition of the medium. In this paper, we propose a method to measure the long-lived RONS concentration in plasma-activated water (PAW) by using UV absorption spectroscopy. Based on an analysis and fit of …


Investigation On The Rons And Bactericidal Effects Induced By He + O2 Cold Plasma Jets: In Open Air And In An Airtight Chamber, Han Xu, Dingxin Liu, Weitao Wang, Zhijie Liu, Li Guo, Mingzhe Rong, Michael G. Kong Nov 2018

Investigation On The Rons And Bactericidal Effects Induced By He + O2 Cold Plasma Jets: In Open Air And In An Airtight Chamber, Han Xu, Dingxin Liu, Weitao Wang, Zhijie Liu, Li Guo, Mingzhe Rong, Michael G. Kong

Bioelectrics Publications

He + O2 plasma jets in open air and in an airtight chamber are comparatively studied, with respect to their production of gaseous/aqueous reactive species and their antibacterial effects. Under the same discharge power, the plasma jet in open air has higher densities of gaseous reactive species and a higher concentration of aqueous H2O2 but lower concentrations of aqueous OH and O2-. In addition, the increase in the O2 ratio in He in both plasma jets causes a linear decrease in the population of gaseous reactive species, except for O(3p5P) …


Predicted Properties Of Microhollow Cathode Discharges In Xenon, J. P. Boeuf, L. C. Pitchford, K. H. Schoenbach Jan 2005

Predicted Properties Of Microhollow Cathode Discharges In Xenon, J. P. Boeuf, L. C. Pitchford, K. H. Schoenbach

Bioelectrics Publications

A fluid model has been developed and used to help clarify the physical mechanisms occurring in microhollow cathode discharges (MHCD). Calculated current-voltage (I-V) characteristics and gas temperatures in xenon at 100 Torr are presented. Consistent with previous experimental results in similar conditions, we find a voltage maximum in the I-V characteristic. We show that this structure reflects a transition between a low-current, abnormal discharge localized inside the cylindrical hollow cathode to a higher-current, normal glow discharge sustained by electron emission from the outer surface of the cathode. This transition, due to the geometry of …


Excimer Emission From Cathode Boundary Layer Discharges, Mohamed Moselhy, Karl H. Schoenbach Jan 2004

Excimer Emission From Cathode Boundary Layer Discharges, Mohamed Moselhy, Karl H. Schoenbach

Bioelectrics Publications

The excimer emission from direct current glow discharges between a planar cathode and a ring-shaped anode of 0.75 and 1.5 mm diameter, respectively, separated by a gap of 250 μm, was studied in xenon and argon in a pressure range from 75 to 760 Torr. The thickness of the “cathode boundary layer” plasma, in the 100 μm range, and a discharge sustaining voltage of approximately 200 V, indicates that the discharge is restricted to the cathode fall and the negative glow. The radiant excimer emittance at 172 nm increases with pressure and reaches a value of 4 W/cm2 for …


Xenon Excimer Emission From Pulsed Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz Jan 2001

Xenon Excimer Emission From Pulsed Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz

Bioelectrics Publications

By applying electrical pulses of 20 ns duration to xenon microplasmas, generated by direct current microhollow cathode discharges, we were able to increase the xenon excimer emission by more than an order of magnitude over direct current discharge excimer emission. For pulsed voltages in excess of 500 V, the optical power at 172 nm was found to increase exponentially with voltage. Largest values obtained were 2.75 W of vacuum-ultraviolet optical power emitted from a single microhollow cathode discharge in 400 Torr xenon with a 750 V pulse applied to a discharge. Highest radiative emittance was 15.2 W/cm2. The …


Resonant Energy Transfer From Argon Dimers To Atomic Oxygen In Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz Jan 2001

Resonant Energy Transfer From Argon Dimers To Atomic Oxygen In Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz

Bioelectrics Publications

The emission of atomic oxygen lines at 130.2 and 130.5 nm from a microhollow cathode discharge in argon with oxygen added indicates resonant energy transfer from argon dimers to oxygen atoms. The internal efficiency of the vacuum-ultraviolet (VUV) radiation was measured as 0.7% for a discharge in 1100 Torr argon with 0.1% oxygen added. The direct current VUV point source operates at voltages below 300 V and at current levels of milliamperes.


Series Operation Of Direct Current Xenon Chloride Excimer Sources, Ahmed El-Habachi, Wenhui Shi, Mohamed Moselhy, Robert H. Stark, Karl H. Schoenbach Jan 2000

Series Operation Of Direct Current Xenon Chloride Excimer Sources, Ahmed El-Habachi, Wenhui Shi, Mohamed Moselhy, Robert H. Stark, Karl H. Schoenbach

Bioelectrics Publications

Stable, direct current microhollow cathode discharges in mixtures of hydrochloric acid, hydrogen, xenon, and neon have been generated in a pressure range of 200–1150 Torr. The cathode hole diameter was 250 μm. Sustaining voltages range from 180 to 250 V at current levels of up to 5 mA. The discharges are strong sources of xenon chloride excimer emission at a wavelength of 308 nm. Internal efficiencies of approximately 3% have been reached at a pressure of 1050 Torr. The spectral radiant power at this pressure was measured as 5 mW/nm at 308 nm for a 3 mA discharge. By using …


Direct Current High-Pressure Glow Discharges, Robert H. Stark, Karl H. Schoenbach Jan 1999

Direct Current High-Pressure Glow Discharges, Robert H. Stark, Karl H. Schoenbach

Bioelectrics Publications

Stabilization and control of a high-pressure glow discharge by means of a microhollow cathode discharge has been demonstrated. The microhollow cathode discharge, which is sustained between two closely spaced electrodes with openings of approximately 100 μm diam, serves as plasma cathode for the high-pressure glow. Small variations in the microhollow cathode discharge voltage generate large variations in the microhollow cathode discharge current and consequently in the glow discharge current. In this mode of operation the electrical characteristic of this system of coupled discharges resembles that of a vacuum triode. Using the microhollow cathode discharge as plasma cathode it was possible …


Generation Of Intense Excimer Radiation From High-Pressure Hollow Cathode Discharges, Ahmed El-Habachi, Karl H. Schoenbach Jan 1998

Generation Of Intense Excimer Radiation From High-Pressure Hollow Cathode Discharges, Ahmed El-Habachi, Karl H. Schoenbach

Bioelectrics Publications

By reducing the diameter of the cathode opening in a hollow cathode discharge geometry to values on the order of 100 μm, we were able to operate these discharges in noble gases in a direct current mode up to atmospheric pressure. High-pressure discharges in xenon were found to be strong sources of excimer radiation. Highest intensities at a wavelength of 172 nm were obtained at a pressure of 400 Torr. At this pressure, the vacuum ultraviolet (VUV) radiant power of a single discharge operating at a forward voltage of 220 V and currents exceeding 2 mA reaches values between 6% …


Emission Of Excimer Radiation From Direct Current, High-Pressure Hollow Cathode Discharge, Ahmed El-Habachi, Karl H. Schoenbach Jan 1998

Emission Of Excimer Radiation From Direct Current, High-Pressure Hollow Cathode Discharge, Ahmed El-Habachi, Karl H. Schoenbach

Bioelectrics Publications

A novel, nonequilibrium, high-pressure, direct current discharge, the microhollow cathode discharge, has been found to be an intense source of xenon and argon excimer radiation peaking at wavelengths of 170 and 130 nm, respectively. In argon discharges with a 100 μm diam hollow cathode, the intensity of the excimer radiation increased by a factor of 5 over the pressure range from 100 to 800 mbar. In xenon discharges, the intensity at 170 nm increased by two orders of magnitude when the pressure was raised from 250 mbar to 1 bar. Sustaining voltages were 200 V for argon and 400 V …


Microhollow Cathode Discharges, K. H. Schoenbach, R. Verhappen, R. Tessnow, F. E. Peterkin, W. W. Byszewski Jan 1996

Microhollow Cathode Discharges, K. H. Schoenbach, R. Verhappen, R. Tessnow, F. E. Peterkin, W. W. Byszewski

Bioelectrics Publications

The current–voltage characteristics of hollow cathode discharges and their predischarges in argon under dc and pulsed conditions were found to have a positive slope at pressures up to approximately 50 Torr, and currents up to 20 mA, at a hole diameter of 0.7 mm. In this range of pressure and current, parallel operation of hollow cathode discharges, without ballast, was demonstrated. Scaling to higher pressure is possible by reducing the hole diameter. Pulsed experiments with an array of cathode rings of 75 μm diameter allowed us to obtain parallel operation of more than 50 discharges at a pressure of 350 …


Paschen's Law For A Hollow Cathode Discharge, H. Eichhorn, K. H. Schoenbach, T. Tessnow Jan 1993

Paschen's Law For A Hollow Cathode Discharge, H. Eichhorn, K. H. Schoenbach, T. Tessnow

Bioelectrics Publications

An expression for the breakdown voltage of a one‐dimensional hollow cathode discharge has been derived. The breakdown condition which corresponds to Paschen’s law contains, in addition to the first Townsend coefficient, and the secondary electron emission coefficient two parameters which characterize the reflecting action of the electric field and the lifetime of the electrons in the discharge. The breakdown voltage for a hollow cathode discharge in helium was calculated and compared to that of a glow discharge operating under similar conditions.


Studies Of High Field Conduction In Diamond For Electron Beam Controlled Switching, R. P. Joshi, M. K. Kennedy, K. H. Schoenbach, W. W. Hofer Jan 1992

Studies Of High Field Conduction In Diamond For Electron Beam Controlled Switching, R. P. Joshi, M. K. Kennedy, K. H. Schoenbach, W. W. Hofer

Bioelectrics Publications

Experimental studies on a vertical metal‐diamond‐silicon switch structure have been conducted for potential pulsed power applications. Both the dc current‐voltage characteristics and the transient switching response have been measured for a range of voltages. With a 1 μm diamond film, the switch has been seen to withstand electric fields up to 1.8 MV/cm. Our results show a polarity dependence which can be associated with current injection at the asymmetric contacts. Polarity effects were also observed in the presence of e‐beam excitation, and arise due to nonuniform carrier generation near the diamond‐silicon interface. Our switching transients were seen to follow …


Bistable Behavior Of The Dark Current In Copper-Doped Semi-Insulating Gallium Arsenide, R. A. Roush, K. H. Schoenbach, R. P. Brinkmann Jan 1992

Bistable Behavior Of The Dark Current In Copper-Doped Semi-Insulating Gallium Arsenide, R. A. Roush, K. H. Schoenbach, R. P. Brinkmann

Bioelectrics Publications

The dark current characteristics of gallium arsenide doped with silicon and compensated with diffused copper were found to have a pronounced region of current controlled negative differential conductivity (ndc) similar to the characteristics of a thyristor. The resistivity of the semi‐insulating semiconductor was measured to be 105 Ω cm for applied voltages up to 2.2 kV, which corresponds to an average electric field of 38 kV/cm. At higher voltages, a transition to a stable high current state was observed with a current rate of rise exceeding 1011 A/s. There is evidence of the formation of at least one …


A Bulk Optically Controlled Semiconductor Switch, Rudolf K.F. Germer, Karl H. Schoenbach, Stephen G.E. Pronko Jan 1988

A Bulk Optically Controlled Semiconductor Switch, Rudolf K.F. Germer, Karl H. Schoenbach, Stephen G.E. Pronko

Bioelectrics Publications

Turn‐on and turn‐off of bulk semiconductor switches, based on excitation and quenching of photoconductivity, respectively, have been demonstrated with copper‐doped II‐VI semiconductor crystals. The increase of the conductivity (turn‐on) was realized with a xenon flash‐lamp pulse of 15‐μs duration. A reduction of the conductivity (turn‐off) was obtained by irradiating the samples with IR light using an 8‐ns Nd:YAG laser pulse (YAG denotes yttrium aluminum garnet). For turn‐on in CdS:Cu the conductivity follows the xenon flash excitation. The turn‐off time constant was 250 ns. ZnS and ZnSe crystals showed a slower response. A memory effect for the IR light was observed.