Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Electrical and Computer Engineering

PDF

Conference papers

2002

Identification

Articles 1 - 1 of 1

Full-Text Articles in Engineering

Closed Loop Identification Of A First Order Plus Dead Time Process Model Under Pi Control, Tony Kealy, Aidan O'Dwyer Jun 2002

Closed Loop Identification Of A First Order Plus Dead Time Process Model Under Pi Control, Tony Kealy, Aidan O'Dwyer

Conference papers

Abstract -- This paper discusses the estimation of the parameters of a first order plus dead-time process model using the closed-loop step response data of the process under proportional plus integral (PI) control. The proportional gain and the integral time, in the PI controller, are chosen such that the closed-loop step response exhibits an under-damped response. From this response data, five characteristic points are used to determine a second order plus dead-time model and subsequently, the frequency response of the closed-loop system. Knowing the dynamics of the closed-loop system and the dynamics of the controller, the open-loop dynamics of the …