Articles 1 - 5 of 5

Full-Text Articles in Engineering

Mash Test Nos. 3-11 And 3-10 On A Non-Proprietary Cable Median Barrier, Justine E. Kohtz, Robert W. Bielenberg, Scott K. Rosenbaugh, Ronald K. Faller, Karla A. Lechtenberg, John D. Reid May 2016

Mash Test Nos. 3-11 And 3-10 On A Non-Proprietary Cable Median Barrier, Justine E. Kohtz, Robert W. Bielenberg, Scott K. Rosenbaugh, Ronald K. Faller, Karla A. Lechtenberg, John D. Reid

Nebraska Department of Transportation: Research Reports

The Midwest States Pooled Fund has been developing a new non-proprietary cable median barrier. This system incorporates four evenly spaced cables, Midwest Weak Posts spaced at 8 to 16 ft (2.4 to 4.9 m) intervals, and a bolted, tabbed bracket to attach the cables to each post. Full-scale crash testing was needed to evaluate the barrier’s safety performance. According to the Manual for Assessing Safety Hardware (MASH) updated/proposed testing matrix for cable barriers installed within a 6H:1V or median ditch, a series of eight full-scale tests are required to evaluate the safety performance of a system. A ninth test is …


Continued Development Of A Non-Proprietary, High-Tension, Cable End Terminal System, Jennifer D. Schmidt, Robert W. Bielenberg, John D. Reid, Ronald K. Faller Apr 2016

Continued Development Of A Non-Proprietary, High-Tension, Cable End Terminal System, Jennifer D. Schmidt, Robert W. Bielenberg, John D. Reid, Ronald K. Faller

Nebraska Department of Transportation: Research Reports

A non-proprietary, cable guardrail system is currently under development for the Midwest States Pooled Fund Program. A cable guardrail end terminal was necessary to accompany the cable guardrail system. The objective of this research project was to develop design recommendations for the cable end terminal. Bogie testing that was previously completed on a design concept indicated delayed cable release, which was an undesired performance that led to vehicle instabilities. Several design changes were recommended for better end terminal performance and to reflect the changes made to the cable median barrier. An LS-DYNA model of the modified cable end terminal was …


Midwest Guardrail System (Mgs) With An Omitted Post, Jessica L. Lingenfelter, Scott Rosenbaugh, Robert W. Bielenberg, Karla A. Lechtenberg, Ronald K. Faller, John D. Reid Feb 2016

Midwest Guardrail System (Mgs) With An Omitted Post, Jessica L. Lingenfelter, Scott Rosenbaugh, Robert W. Bielenberg, Karla A. Lechtenberg, Ronald K. Faller, John D. Reid

Nebraska Department of Transportation: Research Reports

The objective of this research study was to evaluate the MGS (31” tall W-beam guardrail) with an omitted post according to the safety performance criteria provided in MASH. A single full-scale crash test was conducted with the 2270P pickup truck in accordance with MASH test no. 3-11. The small car test, test no. 3-10, was deemed unnecessary as the pickup truck test would result in higher rail loads, a greater propensity for rail rupture, and a greater risk of failure. The test installation utilized standard 6-ft (1.8-m) long steel guardrail posts with 12-in. (305-mm) deep blockouts. A single post was …


Performance Characteristics Of Posts Embedded In Soil, Brandt M. Humphrey, Karla A. Lechtenberg, John D. Reid, Ronald K. Faller, James C. Holloway Aug 2015

Performance Characteristics Of Posts Embedded In Soil, Brandt M. Humphrey, Karla A. Lechtenberg, John D. Reid, Ronald K. Faller, James C. Holloway

Nebraska Department of Transportation: Research Reports

The primary objective of this research study was to determine the post-soil impact reaction of W6x8.5 (W150x12.6) steel posts and 6-in. x 8-in. (152-mm x 203-mm) Southern Yellow Pine (SYP) posts, specifically along the weak axis. Five bogie tests were conducted on W6x8.5 (W150x12.6) A992 steel posts with a length of 72 in. with embedment depths ranging between of 24 and 40 in. (610 and 1,016 mm). Four bogies tests were conducted on 6-in. x 8-in. (152 mm x 203 mm) SYP posts embedded at depths ranging between 30 and 40 in. (735 and 1,016 mm). The target impact conditions …


Design Of An Improved Post For Use In A Non-Proprietary High-Tension Cable Median Barrier, Robert W. Bielenberg, Ronald K. Faller, Karla A. Lechtenberg, Tyler L. Schmidt, Scott K. Rosenbaugh, John D. Reid, Dean L. Sicking May 2015

Design Of An Improved Post For Use In A Non-Proprietary High-Tension Cable Median Barrier, Robert W. Bielenberg, Ronald K. Faller, Karla A. Lechtenberg, Tyler L. Schmidt, Scott K. Rosenbaugh, John D. Reid, Dean L. Sicking

Nebraska Department of Transportation: Research Reports

The objective of this research study was to develop a revised post section for the non-proprietary high-tension cable median barrier that improved the safety and function of the post by lowering strong-axis forces. A total of twenty dynamic component tests were performed, along with one cable pull test – ten tests with the 7-gauge C-section post, eight with the 10-gauge C-Section posts, and three with the Midwest Weak Post (MWP). The tests were conducted with the posts installed in either a compacted, crushed limestone soil or a rigid sleeve in order to determine the force vs. deflection and energy vs. …