Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Engineering

An Immersed Boundary Geometric Preprocessor For Arbitrarily Complex Terrain And Geometry, Inanc Senocak, Micah Sandusky, Rey Deleon, Derek Wade, Kyle Felzien, Marianna Budnikova Nov 2015

An Immersed Boundary Geometric Preprocessor For Arbitrarily Complex Terrain And Geometry, Inanc Senocak, Micah Sandusky, Rey Deleon, Derek Wade, Kyle Felzien, Marianna Budnikova

Mechanical and Biomedical Engineering Faculty Publications and Presentations

There is a growing interest to apply the immersed boundary method to compute wind fields over arbitrarily complex terrain. The computer implementation of an immersed boundary module into an existing flow solver can be accomplished with minor modifications to the rest of the computer program. However, a versatile preprocessor is needed at the first place to extract the essential geometric information pertinent to the immersion of an arbitrarily complex terrain inside a 3D Cartesian mesh. Errors in the geometric information can negatively impact the correct implementation of the immersed boundary method as part of the solution algorithm. Additionally, the distance …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


Microscale Magnetic Field Modulation For Enhanced Capture And Distribution Of Rare Circulating Tumor Cells, Peng Chen, Yu-Yen Huang, Kazunori Hoshino, John X.J Zhang Mar 2015

Microscale Magnetic Field Modulation For Enhanced Capture And Distribution Of Rare Circulating Tumor Cells, Peng Chen, Yu-Yen Huang, Kazunori Hoshino, John X.J Zhang

Dartmouth Scholarship

Immunomagnetic assay combines the powers of the magnetic separation and biomarker recognition and has been an effective tool to perform rare Circulating Tumor Cells detection. Key factors associated with immunomagnetic assay include the capture rate, which indicates the sensitivity of the system, and distributions of target cells after capture, which impact the cell integrity and other biological properties that are critical to downstream analyses. Here we present a theoretical framework and technical approach to implement a microscale magnetic immunoassay through modulating local magnetic field towards enhanced capture and distribution of rare cancer cells. Through the design of a two-dimensional micromagnet …