Simultaneous Evaluation Of Tibiofemoral And Patellofemoral Mechanics In Total Knee Arthroplasty: A Combined Experimental And Computational Approach, Yashar A. Behnam, Ahilan Anantha Krishnan, Hayden Wilson, Chadd W. Clary Jan 2024

Simultaneous Evaluation Of Tibiofemoral And Patellofemoral Mechanics In Total Knee Arthroplasty: A Combined Experimental And Computational Approach, Yashar A. Behnam, Ahilan Anantha Krishnan, Hayden Wilson, Chadd W. Clary

Center for Orthopaedic Biomechanics: Faculty Scholarship

Contemporary total knee arthroplasty (TKA) has not fully restored natural patellofemoral (P-F) mechanics across the patient population. Previous experimental simulations have been limited in their ability to create dynamic, unconstrained, muscle-driven P-F articulation while simultaneously controlling tibiofemoral (T-F) contact mechanics. The purpose of this study was to develop a novel experimental simulation and validate a corresponding finite element model to evaluate T-F and P-F mechanics. A commercially available wear simulator was retrofitted with custom fixturing to evaluate whole-knee TKA mechanics with varying patella heights during a simulated deep knee bend. A corresponding dynamic finite element model was developed to validate …


Model Based Analysis Of The Accuracy And Precision Of Auscultatory Blood Pressure Measurements In Patients With Atrial Fibrillation, Charles F. Babbs Sep 2019

Model Based Analysis Of The Accuracy And Precision Of Auscultatory Blood Pressure Measurements In Patients With Atrial Fibrillation, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Working Papers

Accurate measurement of blood pressure in the presence of atrial fibrillation remains an open problem. The present study combines the techniques of stochastic mathematical modeling with physiological models of the systemic circulation, cuff, and arm (1) to explore mechanisms underlying both the lack of accuracy and the lack of precision in cuff-based arterial pressure measurements during atrial fibrillation and (2) to develop strategies to correct for errors. Both the cardiovascular system and the measurement technique are described using mathematics, including both numerical techniques and analytical probability theory. Preliminary results with numerical models suggested that, despite variability, average systolic pressures tend …


Analytical Cpg Model Driven By Limb Velocity Input Generates Accurate Temporal Locomotor Dynamics, Sergiy Yakovenko, Anton Sobinov, Valeriya Gritsenko Jan 2018

Analytical Cpg Model Driven By Limb Velocity Input Generates Accurate Temporal Locomotor Dynamics, Sergiy Yakovenko, Anton Sobinov, Valeriya Gritsenko

Faculty & Staff Scholarship

The ability of vertebrates to generate rhythm within their spinal neural networks is essential for walking, running, and other rhythmic behaviors. The central pattern generator (CPG) network responsible for these behaviors is well-characterized with experimental and theoretical studies, and it can be formulated as a nonlinear dynam- ical system. The underlying mechanism responsible for locomotor behavior can be expressed as the process of leaky integration with resetting states generating appropriate phases for changing body velocity. The low-dimensional input to the CPG model generates the bilateral pattern of swing and stance modulation for each limb and is consistent with the desired …


Segmental Kinematic Analysis Of Planovalgus Feet During Walking In Children With Cerebral Palsy, Karen M. Kruger, Katherine A. Konop, Joseph Krzak, Adam Graf, Haluk Altiok, Peter A. Smith, Gerald F. Harris May 2017

Segmental Kinematic Analysis Of Planovalgus Feet During Walking In Children With Cerebral Palsy, Karen M. Kruger, Katherine A. Konop, Joseph Krzak, Adam Graf, Haluk Altiok, Peter A. Smith, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

Pes planovalgus (flatfoot) is a common deformity among children with cerebral palsy. The Milwaukee Foot Model (MFM), a multi-segmental kinematic foot model, which uses radiography to align the underlying bony anatomy with reflective surface markers, was used to evaluate 20 pediatric participants (30 feet) with planovalgus secondary to cerebral palsy prior to surgery. Three-dimensional kinematics of the tibia, hindfoot, forefoot, and hallux segments are reported and compared to an age-matched control set of typically-developing children. Most results were consistent with known characteristics of the deformity and showed decreased plantar flexion of the forefoot relative to hindfoot, increased forefoot abduction, and …


Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon Jan 2016

Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon

Mechanical & Aerospace Engineering Faculty Publications

The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focuses on the transient behavior of neural probe and brain tissue interface with a viscoelastic model. Different stages of the interface from initial insertion of neural probe to full bonding of the probe by astro-glial …


Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood Aug 2013

Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood

STAR Program Research Presentations

Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …


The Economics And Logistics Of The Dual Harvest Of Grain And Biomass In A Single-Pass, Matthew T. Wold Dec 2011

The Economics And Logistics Of The Dual Harvest Of Grain And Biomass In A Single-Pass, Matthew T. Wold

Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research

Significant interest has developed in using cellulosic resources, especially crop residues, to create biofuels. Collecting these residues in a single-pass of the harvester across the field has the potential to be a low cost option. Two models have been developed; the first characterizes the in-field logistics of single-pass crop residue collection, the second the economics. These models allow the user to easily examine a wide variety of both grain-only and single-pass residue collection harvest cases. A variety of possible residue collection cases have been examined, and their effects both on harvester field capacity and harvest cost compared to grain-only harvest …


An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, A.J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin Oct 2010

An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, A.J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin

Chemical & Biomedical Engineering Faculty Publications

Background: Currently, natural and synthetic scaffolds are being explored as augmentation devices for rotator cuff repair. When used in this manner, these devices are believed to offer some degree of load sharing; however, no studies have quantified this effect. Furthermore, the manner in which loads on an augmented rotator cuff repair are distributed among the various components of the repair is not known, nor is the relative biomechanical importance of each component. The objectives of this study are to (1) develop quasi-static analytical models of simplified rotator cuff repairs, (2) validate the models, and (3) predict the degree of …


An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin Jan 2010

An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin

Mechanical Engineering Faculty Publications

Background

Currently, natural and synthetic scaffolds are being explored as augmentation devices for rotator cuff repair. When used in this manner, these devices are believed to offer some degree of load sharing; however, no studies have quantified this effect. Furthermore, the manner in which loads on an augmented rotator cuff repair are distributed among the various components of the repair is not known, nor is the relative biomechanical importance of each component. The objectives of this study are to (1) develop quasi-static analytical models of simplified rotator cuff repairs, (2) validate the models, and (3) predict the degree of load …


Performance Characteristics Of A Therapeutic Ultrasound Wire Waveguide, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. Hashmi Mar 2007

Performance Characteristics Of A Therapeutic Ultrasound Wire Waveguide, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. Hashmi

Articles

Therapeutic ultrasound angioplasty has been investigated, clinically, by a number of researchers and represents a potentially promising therapy for the treatment of atherosclerotic lesions. To date, there has been no detailed analysis of the effect of mechanical design parameters, such as wire geometry or damping characteristics, on wire waveguide performance. An apparatus capable of delivering therapeutic ultrasound down small diameter nickel–titanium (NiTi) wire waveguides is described. The output peak-to-peak (p–p) displacements at the distal tip of a 1.0mm diameter waveguide were measured experimentally, by means of an optical microscope and image analysis software. The output was measured for a range …


Development Of A Numerical Model To Simulate Pressure Distributions In Ultrasound Angioplasty, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. Hashmi Jan 2004

Development Of A Numerical Model To Simulate Pressure Distributions In Ultrasound Angioplasty, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. Hashmi

Conference Papers

Ultrasound Angioplasty has been shown to be effective in the removal and re-canalising of blockages in arteries (Siegel RJ, 1993). The ultrasound is delivered via a wire waveguide to the lesion location. The wire, generally, has a ball-tip at the distal end to increase transmission of the ultrasound to the surrounding fluid by causing the ball-tip to oscillate between 20– 45kHz and with displacements of up to 100mm peak-to-peak (Atar, 1999 and Yock, 1997). Pressure waves, micro streaming, cavitation and direct contact with the oscillating ball-tip affect the blockage. Most work to date has concentrated on a spherical ball-tip geometry …