Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Action potential (1)
- Acute Disease (1)
- Additive manufacturing (AM) (1)
- Agent (1)
- Behavior (1)
-
- Biological tissues (1)
- Blood flow (1)
- Bout duration (1)
- Brain Stem (1)
- Brainstem encephalitis (1)
- Cardiac magnetic resonance (1)
- Cardiac mechanics (1)
- Cardiac remodeling (1)
- Cardiovascular disease (1)
- Cardiovascular magnetic resonance (1)
- Case-Control Studies (1)
- Charge-coupled-device (1)
- Chemoradiation therapy (1)
- Child (1)
- Classifier (1)
- Clustering (1)
- Compositions (1)
- Conduction velocity restitution (1)
- Convalescence (1)
- Diffuse optics (1)
- Diffuse speckle contrast (1)
- Discordant alternans (1)
- EEG (1)
- EMG (1)
- Encephalitis, Viral (1)
Articles 1 - 11 of 11
Full-Text Articles in Engineering
Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia
Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia
Mechanical Engineering Faculty Publications
Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, …
Polymeric Prodrug, David A. Puleo, Thomas D. Dziubla, Theodora Asafo-Adjei
Polymeric Prodrug, David A. Puleo, Thomas D. Dziubla, Theodora Asafo-Adjei
Biomedical Engineering Faculty Patents
The presently-disclosed subject matter includes compounds that comprise an initiator and an active agent that is covalently bonded to the initiator through a ring-opening polymerization process, an atom-transfer radical polymerization process, a Michael addition reaction, or a ring-opening metathesis polymerization process. In some embodiments the active agent includes simvastatin. The presently-disclosed subject matter also includes methods for making the compositions and methods for using the compositions to treat tissue wounds.
An Interactive Videogame Designed To Improve Respiratory Navigator Efficiency In Children Undergoing Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Jonathan D. Grabau, Kristin N. Andres, Moriel H. Vandsburger, David K. Powell, Vincent L. Sorrell, Brandon K. Fornwalt
An Interactive Videogame Designed To Improve Respiratory Navigator Efficiency In Children Undergoing Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Jonathan D. Grabau, Kristin N. Andres, Moriel H. Vandsburger, David K. Powell, Vincent L. Sorrell, Brandon K. Fornwalt
Saha Cardiovascular Research Center Faculty Publications
Background: Advanced cardiovascular magnetic resonance (CMR) acquisitions often require long scan durations that necessitate respiratory navigator gating. The tradeoff of navigator gating is reduced scan efficiency, particularly when the patient’s breathing patterns are inconsistent, as is commonly seen in children. We hypothesized that engaging pediatric participants with a navigator-controlled videogame to help control breathing patterns would improve navigator efficiency and maintain image quality.
Methods: We developed custom software that processed the Siemens respiratory navigator image in real-time during CMR and represented diaphragm position using a cartoon avatar, which was projected to the participant in the scanner as visual feedback. The …
Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemoradiation Therapy Outcomes, Lixin Dong, Mahesh Kudrimoti, Daniel Irwin, Li Chen, Sameera Kumar, Yu Shang, Chong Huang, Ellis L. Johnson, Scott D. Stevens, Brent J. Shelton, Guoqiang Yu
Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemoradiation Therapy Outcomes, Lixin Dong, Mahesh Kudrimoti, Daniel Irwin, Li Chen, Sameera Kumar, Yu Shang, Chong Huang, Ellis L. Johnson, Scott D. Stevens, Brent J. Shelton, Guoqiang Yu
Biomedical Engineering Faculty Publications
This study used a hybrid near-infrared diffuse optical instrument to monitor tumor hemodynamic responses to chemoradiation therapy for early prediction of treatment outcomes in patients with head and neck cancer. Forty-seven patients were measured once per week to evaluate the hemodynamic status of clinically involved cervical lymph nodes as surrogates for the primary tumor response. Patients were classified into two groups: complete response (CR) (n = 29) and incomplete response (IR) (n = 18). Tumor hemodynamic responses were found to be associated with clinical outcomes (CR/IR), wherein the associations differed depending on human papillomavirus (HPV-16) status. In HPV-16 …
Low-Cost Compact Diffuse Speckle Contrast Flowmeter Using Small Laser Diode And Bare Charge-Coupled-Device, Chong Huang, Myeongsu Seong, Joshua Paul Morgan, Siavash Mazdeyasna, Jae Gwan Kim, Jeffrey Todd Hastings, Guoqiang Yu
Low-Cost Compact Diffuse Speckle Contrast Flowmeter Using Small Laser Diode And Bare Charge-Coupled-Device, Chong Huang, Myeongsu Seong, Joshua Paul Morgan, Siavash Mazdeyasna, Jae Gwan Kim, Jeffrey Todd Hastings, Guoqiang Yu
Biomedical Engineering Faculty Publications
We report a low-cost compact diffuse speckle contrast flowmeter (DSCF) consisting of a small laser diode and a bare charge-coupled-device (CCD) chip, which can be used for contact measurements of blood flow variations in relatively deep tissues (up to ∼8 mm). Measurements of large flow variations by the contact DSCF probe are compared to a noncontact CCD-based diffuse speckle contrast spectroscopy and a standard contact diffuse correlation spectroscopy in tissue phantoms and a human forearm. Bland–Altman analysis shows no significant bias with good limits of agreement among these measurements: 96.5% ± 2.2% (94.4% to 100.0%) in phantom experiments and 92.8% …
Cardiac Remodeling And Dysfunction In Childhood Obesity: A Cardiovascular Magnetic Resonance Study, Linyuan Jing, Cassi M. Binkley, Jonathan D. Suever, Nivedita Umasankar, Christopher M. Haggerty, Jennifer Rich, Christopher D. Nevius, Gregory J. Wehner, Sean M. Hamlet, David K. Powell, Aurelia Radulescu, H. Lester Kirchner, Frederick H. Epstein, Brandon K. Fornwalt
Cardiac Remodeling And Dysfunction In Childhood Obesity: A Cardiovascular Magnetic Resonance Study, Linyuan Jing, Cassi M. Binkley, Jonathan D. Suever, Nivedita Umasankar, Christopher M. Haggerty, Jennifer Rich, Christopher D. Nevius, Gregory J. Wehner, Sean M. Hamlet, David K. Powell, Aurelia Radulescu, H. Lester Kirchner, Frederick H. Epstein, Brandon K. Fornwalt
Pediatrics Faculty Publications
Background: Obesity affects nearly one in five children and is associated with increased risk of premature death. Obesity-related heart disease contributes to premature death. We aimed to use cardiovascular magnetic resonance (CMR) to comprehensively characterize the changes in cardiac geometry and function in obese children.
Methods and results: Forty-one obese/overweight (age 12 ± 3 years, 56 % female) and 29 healthy weight children (age 14 ± 3 years, 41 % female) underwent CMR, including both standard cine imaging and displacement encoded imaging, for a complete assessment of left ventricular (LV) structure and function. After adjusting for age, LV mass index …
Mri Signal Intensity Differentiation Of Brainstem Encephalitis Induced By Enterovirus 71: A Classification Approach For Acute And Convalescence Stages, Hongwu Zeng, Wenxian Huang, Feiqiu Wen, Yonker Wang, Yungen Gan, Weibin Zeng, Ranran Chen, Yanxia He, Zaiyi Liu, Changhong Liang, Kelvin K. L. Wong
Mri Signal Intensity Differentiation Of Brainstem Encephalitis Induced By Enterovirus 71: A Classification Approach For Acute And Convalescence Stages, Hongwu Zeng, Wenxian Huang, Feiqiu Wen, Yonker Wang, Yungen Gan, Weibin Zeng, Ranran Chen, Yanxia He, Zaiyi Liu, Changhong Liang, Kelvin K. L. Wong
Radiology Faculty Publications
Background: The objective of this study is to assess standardized histograms of signal intensities of T1 signal and T2 signal on sagittal view without enhancement during (1) acute stage, and (2) convalescence stage of pediatric patients with Enterovirus 71 related brainstem encephalitis (BE), and with respect to (3) healthy normal.
Methods: Our subjects were hospitalized between March 2010 and October 2012, and underwent pre- and post-contrast MRI studies. The research question to be answered is whether the comparison of the MRI image intensity histograms and relevant statistical quantification can add new knowledge to the diagnosis of BE patients. So, both …
Segway: A Simple Framework For Unsupervised Sleep Segmentation In Experimental Eeg Recordings, Farid Yaghouby, Sridhar Sunderam
Segway: A Simple Framework For Unsupervised Sleep Segmentation In Experimental Eeg Recordings, Farid Yaghouby, Sridhar Sunderam
Biomedical Engineering Faculty Publications
Sleep analysis in animal models typically involves recording an electroencephalogram (EEG) and electromyogram (EMG) and scoring vigilance state in brief epochs of data as Wake, REM (rapid eye movement sleep) or NREM (non-REM) either manually or using a computer algorithm. Computerized methods usually estimate features from each epoch like the spectral power associated with distinctive cortical rhythms and dissect the feature space into regions associated with different states by applying thresholds, or by using supervised/unsupervised statistical classifiers; but there are some factors to consider when using them:
- Most classifiers require scored sample data, elaborate heuristics or computational steps not easily …
Human Igg1 Antibodies Suppress Angiogenesis In A Target-Independent Manner, Sasha Bogdanovich, Younghee Kim, Takeshi Mizutani, Reo Yasuma, Laura Tudisco, Valeria Cicatiello, Ana Bastos-Carvalho, Nagaraj Kerur, Yoshio Hirano, Judit Z. Baffi, Valeria Tarallo, Shengjian Li, Tetsuhiro Yasuma, Parthasarathy Arpitha, Benjamin James Fowler, Charles B. Wright, Ivana Apicella, Adelaide Greco, Arturo Brunetti, Menotti Ruvo, Annamaria Sandomenico, Miho Nozaki, Ryo Ijima, Hiroki Kaneko, Yuichiro Ogura, Hiroko Terasaki, Balamurali K. Ambati, Jeanette H. W. Leusen, Wallace Y. Langdon, Michael R. Clark, Bradley D. Gelfand, Jayakrishna Ambati
Human Igg1 Antibodies Suppress Angiogenesis In A Target-Independent Manner, Sasha Bogdanovich, Younghee Kim, Takeshi Mizutani, Reo Yasuma, Laura Tudisco, Valeria Cicatiello, Ana Bastos-Carvalho, Nagaraj Kerur, Yoshio Hirano, Judit Z. Baffi, Valeria Tarallo, Shengjian Li, Tetsuhiro Yasuma, Parthasarathy Arpitha, Benjamin James Fowler, Charles B. Wright, Ivana Apicella, Adelaide Greco, Arturo Brunetti, Menotti Ruvo, Annamaria Sandomenico, Miho Nozaki, Ryo Ijima, Hiroki Kaneko, Yuichiro Ogura, Hiroko Terasaki, Balamurali K. Ambati, Jeanette H. W. Leusen, Wallace Y. Langdon, Michael R. Clark, Bradley D. Gelfand, Jayakrishna Ambati
Ophthalmology and Visual Science Faculty Publications
Aberrant angiogenesis is implicated in diseases affecting nearly 10% of the world’s population. The most widely used anti-angiogenic drug is bevacizumab, a humanized IgG1 monoclonal antibody that targets human VEGFA. Although bevacizumab does not recognize mouse Vegfa, it inhibits angiogenesis in mice. Here we show bevacizumab suppressed angiogenesis in three mouse models not via Vegfa blockade but rather Fc-mediated signaling through FcγRI (CD64) and c-Cbl, impairing macrophage migration. Other approved humanized or human IgG1 antibodies without mouse targets (adalimumab, alemtuzumab, ofatumumab, omalizumab, palivizumab and tocilizumab), mouse IgG2a, and overexpression of human IgG1-Fc or mouse IgG2a-Fc, also inhibited angiogenesis in wild-type …
Supernormal Conduction And Suppression Of Spatially Discordant Alternans Of Cardiac Action Potentials, Linyuan Jing, Anuj Agarwal, Abhijit R. Patwardhan
Supernormal Conduction And Suppression Of Spatially Discordant Alternans Of Cardiac Action Potentials, Linyuan Jing, Anuj Agarwal, Abhijit R. Patwardhan
Biomedical Engineering Faculty Publications
Spatially discordant alternans (DA) of action potential durations (APD) is thought to be more pro-arrhythmic than concordant alternans. Super normal conduction (SNC) has been reported to suppress formation of DA. An increase in conduction velocity (CV) as activation rate increases, i.e., a negative CV restitution, is widely considered as hallmark of SNC. Our aim in this study is to show that it is not an increase in CV for faster rates that prevents formation of DA, rather, it is the ratio of the CV for the short relative to the long activation that is critical in DA suppression. To illustrate …
Recent Advances In Optical Spectroscopic And Imaging Methods For Medicine And Biology, Yu Shang, Zhiyu Qian, Rickson C. Mesquita, Mathieu Dehaes
Recent Advances In Optical Spectroscopic And Imaging Methods For Medicine And Biology, Yu Shang, Zhiyu Qian, Rickson C. Mesquita, Mathieu Dehaes
Biomedical Engineering Faculty Publications
No abstract provided.