Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Engineering

Sequential Structural And Fluid Dynamics Analysis Of Balloon-Expandable Coronary Stents., David Martin Oct 2013

Sequential Structural And Fluid Dynamics Analysis Of Balloon-Expandable Coronary Stents., David Martin

Doctoral

As in-stent restenosis following coronary stent deployment has been strongly linked with stent-induced arterial injury and altered vessel hemodynamics, the sequential numerical analysis of the mechanical and hemodynamic impact of stent deployment within a coronary artery is likely to provide an excellent indication of coronary stent performance. Despite this observation, very few numerical studies have considered both the mechanical and hemodynamic impact of stent deployment. In light of this observation, the aim of this research is to develop a robust numerical methodology for investigating the performance of balloon-expandable coronary stents in terms of their mechanical and hemodynamic impact within a …


Measurement And Description Of Dynamics Required For In Vivo Surgical Robotics Via Kinematic Methods, Jacob G. Greenburg Aug 2013

Measurement And Description Of Dynamics Required For In Vivo Surgical Robotics Via Kinematic Methods, Jacob G. Greenburg

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

With the goal of improved recovery times and reduced trauma to the patient there has been a substantial shift in the medical community’s demand for minimally invasive surgical (MIS) techniques. With the standardization of MIS becoming more commonplace in the medical field there are still many improvements that are desired. Traditional, manual methods of these surgeries require multiple incisions on the abdomen for the tools and instruments to be inserted. The more recent demand has been to localize the incisions into what is being referred to as a Laparoendoscopic Single-Site (LESS) surgery. Furthermore, the manual instruments that are commonly used …


Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood Aug 2013

Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood

STAR Program Research Presentations

Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …


Experimental Assessment Of The Impact Of Asymptomatic Gas Emboli On The Vessel Wall, Linxia Gu, Eric L. Cutler Jun 2013

Experimental Assessment Of The Impact Of Asymptomatic Gas Emboli On The Vessel Wall, Linxia Gu, Eric L. Cutler

Department of Mechanical and Materials Engineering: Faculty Publications

Quantitative evaluation of shear stress in the vessel wall due to the presence of asymptomatic gas emboli is lacking. The goal of this work was to assess the impact of chronic asymptomatic gas emboli on the risk of atherosclerosis through a custom-built cardiovascular flow simulator. Gas bubbles were created by forced air from a syringe pump. The influences of embolism injection rate, pulse rate, and time-averaged flow rate on the wall mean shear stress were investigated at resting and elevated heart rate conditions. The recorded pressure and volumetric flow rate from 24 experimental settings with four repetitions each were used …


Mechanics Of Blast Loading On Post-Mortem Human And Surrogate Heads In The Study Of Traumatic Brain Injury (Tbi) Using Experimental And Computational Approaches, Shailesh Govind Ganpule Mar 2013

Mechanics Of Blast Loading On Post-Mortem Human And Surrogate Heads In The Study Of Traumatic Brain Injury (Tbi) Using Experimental And Computational Approaches, Shailesh Govind Ganpule

Department of Engineering Mechanics: Dissertations, Theses, and Student Research

Blast induced neurotrauma (BINT) has been designated as the “signature injury” to warfighters in the recent military conflicts. The occurrence of traumatic brain injury (TBI) in blasts is controversial in the medical and scientific communities because the manifesting symptoms occur without visible injuries. Whether the primary blast waves alone can cause mechanical insult that is comparable to existing traumatic brain injury thresholds is still an open question, and this work is aimed to address this issue.

In the first part of this dissertation, mechanics of primary blast loading on Realistic Explosive Dummy (RED) head with and without helmets is studied …


Biogeography-Based Optimization For Hydraulic Prosthetic Knee Control, Tim Wilmot, George Thomas, Berney Montavon, Rick Rarick, Antonie J. Van Den Bogert, Steve Szatmary, Daniel J. Simon, William Smith, Sergey Samorezov Jan 2013

Biogeography-Based Optimization For Hydraulic Prosthetic Knee Control, Tim Wilmot, George Thomas, Berney Montavon, Rick Rarick, Antonie J. Van Den Bogert, Steve Szatmary, Daniel J. Simon, William Smith, Sergey Samorezov

Electrical and Computer Engineering Faculty Publications

We discuss open-loop control development and simulation results for a newly-developed cyber-physical system (CPS) used as a semi-active, above-knee prosthesis. The control signal of our CPS consists of two hydraulic valve settings that control a linear cylinder actuator and provide torque to the prosthetic knee. We develop open-loop control using biogeography-based optimization (BBO), which is a recently developed evolutionary algorithm. The research contributes to the field of cyber-physical systems by showing that it is possible to find effective open-loop control signals for our newly proposed semi-active hydraulic knee prosthesis through a dual-system optimization process which includes both human and robot …


Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren Jan 2013

Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren

Mechanical & Aerospace Engineering Faculty Publications

A three-dimensional (3D) computational fluid dynamics study of shear rates around distal end-to-side anastomoses has been conducted. Three 51% and three 75% cross-sectional area-reduced 6 mm cylinders were modeled each with a bypass cylinder attached at a 30-degree angle at different placements distal to the constriction. Steady, incompressible, Newtonian blood flow was assumed, and the full Reynolds-averaged Navier-Stokes equations, turbulent kinetic energy, and specific dissipation rate equations were solved on a locally structured multiblock mesh with hexahedral elements. Consequently, distal placement of an end-to-side bypass graft anastomosis was found to have an influence on the shear rate magnitudes. For the …