Monte Carlo And Experimental Analysis Of A Novel Directional Rotating Scatter Mask Gamma Detection System, Julie V. Logan, Darren E. Holland, Larry W. Burggraf, Justin A. Clinton, Buckley E. O'Day Iii Dec 2019

Monte Carlo And Experimental Analysis Of A Novel Directional Rotating Scatter Mask Gamma Detection System, Julie V. Logan, Darren E. Holland, Larry W. Burggraf, Justin A. Clinton, Buckley E. O'Day Iii

Faculty Publications

Excerpt: This work demonstrates successful experimental operation of a prototype system to identify source direction which was modeled using a library of signals simulated using GEANT and a novel algorithm....


Deep Donors And Acceptors In Β-Ga2O3 Crystals: Determination Of The Fe2+/3+ Level By A Noncontact Method, Christopher A. Lenyk, Trevor A . Gustafson, Larry E. Halliburton, Nancy C. Giles Dec 2019

Deep Donors And Acceptors In Β-Ga2O3 Crystals: Determination Of The Fe2+/3+ Level By A Noncontact Method, Christopher A. Lenyk, Trevor A . Gustafson, Larry E. Halliburton, Nancy C. Giles

Faculty Publications

Electron paramagnetic resonance (EPR), infrared absorption, and thermoluminescence (TL) are used to determine the Fe2+/3+ level in Fe-doped β-Ga2O3 crystals. With these noncontact spectroscopy methods, a value of 0.84 ± 0.05 eV below the conduction band is obtained for this level. Our results clearly establish that the E2 level observed in deep level transient spectroscopy (DLTS) experiments is due to the thermal release of electrons from Fe2+ ions. The crystals used in this investigation were grown by the Czochralski method and contained large concentrations of Fe acceptors and Ir donors, and trace amounts of Cr …


Quantitative Analysis Of Cerium-Gallium Alloys Using A Hand-Held Laser Induced Breakdown Spectroscopy Device, Ashwin P. Rao, Matthew Cook, Howard L. Hall, Michael B. Shattan Sep 2019

Quantitative Analysis Of Cerium-Gallium Alloys Using A Hand-Held Laser Induced Breakdown Spectroscopy Device, Ashwin P. Rao, Matthew Cook, Howard L. Hall, Michael B. Shattan

Faculty Publications

A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0–3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4-nm emission line was determined to be superior for the purposes of Ga detection and concentration determination. A limit of detection below 0.25%was achieved using a multivariate regression model of the Ga I …