Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Missouri University of Science and Technology (740)
- California Polytechnic State University, San Luis Obispo (448)
- University of Nebraska - Lincoln (308)
- Technological University Dublin (113)
- University of North Alabama (86)
-
- United Arab Emirates University (71)
- Association of Arab Universities (52)
- The British University in Egypt (48)
- Western Kentucky University (45)
- Syracuse University (44)
- Indiana State University (31)
- University of Nevada, Las Vegas (24)
- Oral Roberts University (22)
- Kennesaw State University (17)
- Purdue University (15)
- American University in Cairo (14)
- Beirut Arab University (13)
- City University of New York (CUNY) (13)
- University of Arkansas, Fayetteville (13)
- University of Southern Maine (13)
- East Tennessee State University (12)
- Clemson University (8)
- Louisiana State University (8)
- Rhode Island School of Design (8)
- Old Dominion University (7)
- Portland State University (7)
- University of the Pacific (6)
- Munster Technological University (5)
- Universitas Indonesia (5)
- Faculty of Engineering, Mansoura University (4)
- Keyword
-
- Architecture (83)
- University Architecture (80)
- University of North Alabama history (80)
- University Buildings (72)
- College Campuses in Alabama (71)
-
- Sustainability (57)
- Construction (46)
- University of North Alabama (41)
- Concrete (40)
- Design (38)
- Engineering (35)
- Rheology (27)
- Hospital (26)
- Western Kentucky University (24)
- Florence State Teachers College (23)
- City of Faith (22)
- Oral Roberts (22)
- Citiplex Towers (21)
- Medical Complex (21)
- Noise (21)
- Oral Roberts University (21)
- Prayer and Medicine (21)
- Architectural Engineering (20)
- BIM (20)
- Healing (20)
- Retrofit (20)
- Structure (17)
- Reinforced concrete (16)
- Self-consolidating concrete (16)
- Energy (15)
- Publication Year
- Publication
-
- Civil, Architectural and Environmental Engineering Faculty Research & Creative Works (662)
- Architectural Engineering (436)
- Durham School of Architectural Engineering and Construction: Faculty Publications (219)
- Documents (82)
- Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research (74)
-
- Journal of Engineering Research (41)
- Conference papers (36)
- Master's Theses (29)
- Theses (29)
- Articles (28)
- All-Inclusive List of Electronic Theses and Dissertations (26)
- The Bridge Newsletter (24)
- City of Faith (22)
- Thesis/ Dissertation Defenses (22)
- Architecture Senior Theses (20)
- Construction Management (17)
- WKU Archives Collection Inventories (16)
- Emirates Journal for Engineering Research (15)
- Capstone Reports (14)
- Theses and Dissertations (14)
- Civil, Architectural and Environmental Engineering Scholarly Productivity Reports (13)
- ENTC 2160: Architectural CAD (11)
- Publications and Research (11)
- Architecture and Planning Journal (APJ) (10)
- Bachelor of Architecture Theses - 5th Year (10)
- Faculty Publications (10)
- Other Resources (10)
- Community Design Center Project Reports (9)
- Masters Theses & Specialist Projects (9)
- Ogden College of Science & Engineering Publications (9)
- Publication Type
- File Type
Articles 1351 - 1380 of 2299
Full-Text Articles in Architecture
Engineering Behavior And Characteristics Of Water-Soluble Polymers: Implication On Soil Remediation And Enhanced Oil Recovery, Shuang Cindy Cao, Bate Bate, Jong Wan Hu, Jongwon Jung
Engineering Behavior And Characteristics Of Water-Soluble Polymers: Implication On Soil Remediation And Enhanced Oil Recovery, Shuang Cindy Cao, Bate Bate, Jong Wan Hu, Jongwon Jung
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
Biopolymers have shown a great effect in enhanced oil recovery because of the improvement of water-flood performance by mobility control, as well as having been considered for oil contaminated-soil remediation thanks to their mobility control and water-flood performance. This study focused on the wettability analysis of biopolymers such as chitosan (85% deacetylated power), PEO (polyethylene oxide), Xanthan (xanthan gum), SA (Alginic Acid Sodium Salt), and PAA (polyacrylic acid), including the measurements of contact angles, interfacial tension, and viscosity. Furthermore, a micromodel study was conducted to explore pore-scale displacement phenomena during biopolymer injection into the pores. The contact angles of biopolymer …
The Bridge Newsletter Spring 2016, Missouri University Of Science And Technology
The Bridge Newsletter Spring 2016, Missouri University Of Science And Technology
The Bridge Newsletter
-Steel Bridge Team qualifies for nationals
-Concrete, reimagined
-Going with the flow
-Remembering Vernon T. Jones
Case Study Of Quantifying Energy Loss Through Ceiling-Attic Recessed Lighting Fixtures Through 3d Numerical Simulation, Ri Na, Shengmao Lin, Zhigang Shen, Linxia Gu
Case Study Of Quantifying Energy Loss Through Ceiling-Attic Recessed Lighting Fixtures Through 3d Numerical Simulation, Ri Na, Shengmao Lin, Zhigang Shen, Linxia Gu
Durham School of Architectural Engineering and Construction: Faculty Publications
Air leakage through improperly installed recessed lighting fixtures has been identified as a common issue causing extra energy consumption of residential buildings. However, little quantitative study was found in this area. In this paper, a preliminary evaluation of the magnitude of such energy loss was conducted by numerical simulations using 3 dimensional transient computational fluid dynamics (CFD) model. A typical layout of recessed lighting fixtures was used in this case study with boundary conditions in four different seasons, which were obtained from past measured roof/attic temperature data sets. The results of the numerical simulations indicate that leakage of recessed lighting …
Designing A Residence In Sweden, Umeki Earl, Olivia Bufalini
Designing A Residence In Sweden, Umeki Earl, Olivia Bufalini
School of Human Sciences Research Showcase
The project was to design a home for the Nordstroms, a family who lived in Sweden. The challenge was to design a home for the family of four with a maximum square footage of 1100 square feet using the codes and space allocations required for another country. Meeting the needs of the client required much research. RESEARCH included studying the regional climate, the municipal building codes, and city regulations. Thorough research of building construction framing methods, insulation types and installation methods, site planning, materials and finishes were also essential for completing the project.
2016 Scholarly Productivity Report, Missouri University Of Science And Technology
2016 Scholarly Productivity Report, Missouri University Of Science And Technology
Civil, Architectural and Environmental Engineering Scholarly Productivity Reports
No abstract provided.
A Need For Evidence-Based And Multidisciplinary Research To Study The Effects Of The Interaction Of School Environmental Conditions On Student Achievement, Josephine Lau, Lily M. Wang, Clarence E. Waters, James A. Bovaird
A Need For Evidence-Based And Multidisciplinary Research To Study The Effects Of The Interaction Of School Environmental Conditions On Student Achievement, Josephine Lau, Lily M. Wang, Clarence E. Waters, James A. Bovaird
Durham School of Architectural Engineering and Construction: Faculty Publications
With funding from the U.S. Environmental Protection Agency’s (EPA) Healthy Schools initiative, a research team from the University of Nebraska– Lincoln (UNL) is currently working on establishing how environmental conditions in K-12 school buildings impact student scholastic achievement. The objectives of the research project are: (1) to study comprehensively the impacts of a wide set of indoor environmental factors (including indoor air quality, thermal, lighting and acoustic conditions) on student achievement; (2) to investigate how these environmental conditions interact with each other to impact student achievement; (3) to rank order the environmental variables in terms of their relative impact on …
Cognitive Radio For Smart Grid With Security Considerations, Khaled Shuaib, Ezedin Barka, Nedaa Al Hussien, Mohammed Abdel-Hafez, Mahmoud Alahmad
Cognitive Radio For Smart Grid With Security Considerations, Khaled Shuaib, Ezedin Barka, Nedaa Al Hussien, Mohammed Abdel-Hafez, Mahmoud Alahmad
Durham School of Architectural Engineering and Construction: Faculty Publications
In this paper, we investigate how Cognitive Radio as a means of communication can be utilized to serve a smart grid deployment end to end, from a home area network to power generation. We show how Cognitive Radio can be mapped to integrate the possible different communication networks within a smart grid large scale deployment. In addition, various applications in smart grid are defined and discussed showing how Cognitive Radio can be used to fulfill their communication requirements. Moreover, information security issues pertained to the use of Cognitive Radio in a smart grid environment at different levels and layers are …
Normalized Effect Of Condenser Fouling And Refrigerant Charge On Performance Of Vapor Compression Air Conditioning Systems, Mehdi Mehrabi, David Yuill
Normalized Effect Of Condenser Fouling And Refrigerant Charge On Performance Of Vapor Compression Air Conditioning Systems, Mehdi Mehrabi, David Yuill
Durham School of Architectural Engineering and Construction: Faculty Publications
Several laboratory experiments have studied the effect of faults on vapor compression cycle air-conditioning systems. There has been a particular focus on refrigerant charge variation, which is believed to be quite common in air conditioners, and a lesser focus on heat exchanger fouling. The majority of the published results evaluate the fault effects on particular system operating parameters in one unit. For example, the effect on capacity and efficiency are typically evaluated. The results differ from one study to the next. The current paper summarizes the effects for all of the results available in the literature for condenser fouling and …
Divisible Cities, Noel Brady
No Reduction By Propane Over Monolithic Cordierite-Based Fe/Al2o3 Catalyst: Reaction Mechanism And Effect Of H2o/So2, Hao Zhou, Yaxin Su, Wenyu Liao, Wenyi Deng, Fangchuan Zhong
No Reduction By Propane Over Monolithic Cordierite-Based Fe/Al2o3 Catalyst: Reaction Mechanism And Effect Of H2o/So2, Hao Zhou, Yaxin Su, Wenyu Liao, Wenyi Deng, Fangchuan Zhong
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
The selective reduction of NO by C3H8and the sensitivity to H2O and SO2have been studied over monolithic cordierite-based Fe/Al2O3catalysts, which were prepared by the sol–gel and impregnation method. The catalysts were investigated by N2 adsorption, X-ray diffraction (XRD), scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS) and in situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) techniques. Results showed that NO reduction was more than 90% in the absence of oxygen at 500 °C and in the presence of oxygen at 600 °C respectively. In a continues …
Development Of Coordination Control For Multiple Rooftop Units, Denchai Woradechjumroen, Haorong Li, Akekachai Deesiri
Development Of Coordination Control For Multiple Rooftop Units, Denchai Woradechjumroen, Haorong Li, Akekachai Deesiri
Durham School of Architectural Engineering and Construction: Faculty Publications
Rooftop Units (RTUs) have been widely applied in providing space heating and cooling for commercial buildings. In total, they serve over 60% of the commercial building floor space in the U.S. Even through the current control approaches of a RTU can maintain the zone temperature corresponding to a set point temperature, it performs inefficiently due to several factors such as limited sensing capability, non- coordinated local control, inherent oversizing effects and so on. In addition to unnecessary power consumptions, the current control and operation technology on RTUs also lead to the space humidity problem, equipment efficiency degradation, and premature failure. …
Fault Diagnosis Of Refrigerant Charge Based On Pca And Decision Tree For Variable Refrigerant Flow Systems, Jiangyan Liu, Huanxin Chen, Jiangyu Wang, Guannan Li, Haorong Li, Wenju Hu
Fault Diagnosis Of Refrigerant Charge Based On Pca And Decision Tree For Variable Refrigerant Flow Systems, Jiangyan Liu, Huanxin Chen, Jiangyu Wang, Guannan Li, Haorong Li, Wenju Hu
Durham School of Architectural Engineering and Construction: Faculty Publications
Variable refrigerant flow (VRF) systems are easily subjected to performance degradation due to refrigerant leakage, mechanical failure or improper maintenance after years of operation. Ideal VRF systems should equip with fault detection and diagnosis (FDD) program to sustain its normal operation. This paper presents the fault diagnosis method for refrigerant charge faults of variable refrigerant flow (VRF) systems. It is developed based on the classification and regression tree (CART) algorithm. Data of the experimental VRF system is used to test the advantages of the CART method. Results show that the decision tree can achieve desirable diagnosis efficiency on undercharge faults, …
The Impact Of The Ambient Environment And Building Configuration On Occupant Productivity In Open-Plan Commercial Offices, Mark Mulville, Nicola Callaghan, David Isaac
The Impact Of The Ambient Environment And Building Configuration On Occupant Productivity In Open-Plan Commercial Offices, Mark Mulville, Nicola Callaghan, David Isaac
Articles
Purpose
This paper sets out to understand the impact of the ambient environment on perceived comfort, health, wellbeing and by extension productivity in the workplace.
Design/methodology/approach
The research combined an occupant survey considering satisfaction with the ambient environment, health and wellbeing and workplace behaviour with the monitoring of ambient environmental conditions.
Findings
The paper demonstrates that the ambient environment can have a significant impact on occupant comfort, health and wellbeing, which in turn has implications for built asset performance. Within the ambient environmental factors considered, a hierarchy may exist with noise being of particular importance. Occupant behaviour within the workplace …
A Thermo-Activated Wall For Load Reduction And Supplementary Cooling With Free To Low-Cost Thermal Water, Yuebin Yu, Fuxin Niu, Heinz-Axel Guo, Denchai Woradechjumroen
A Thermo-Activated Wall For Load Reduction And Supplementary Cooling With Free To Low-Cost Thermal Water, Yuebin Yu, Fuxin Niu, Heinz-Axel Guo, Denchai Woradechjumroen
Durham School of Architectural Engineering and Construction: Faculty Publications
A building envelope serves as a thermal barrier and plays an important role in determining the amount of energy used to achieve a comfortable indoor environment. Conventionally, it is constructed and treated as a passive component in a building thermal energy system. In this article, a novel, mini-tube capillary-network embedded and thermal-water activated building envelope is proposed to turn the passive component into active, therefore broaden the direct utilization of low-grade thermal energy in buildings. With this proposed approach, low-grade thermal water at a medium temperature close to the ambient environment can be potentially utilized to either counterbalance the thermal …
Student Absenteeism And The Comparisons Of Two Sampling Procedures For Culturable Bioaerosol Measurement In Classrooms With And Without Upper Room Ultraviolet Germicidal Irradiation Devices, Chunxiao Su, Josephine Lau, Shawn G. Gibbs
Student Absenteeism And The Comparisons Of Two Sampling Procedures For Culturable Bioaerosol Measurement In Classrooms With And Without Upper Room Ultraviolet Germicidal Irradiation Devices, Chunxiao Su, Josephine Lau, Shawn G. Gibbs
Durham School of Architectural Engineering and Construction: Faculty Publications
Upper room ultraviolet germicidal irradiance (UVGI) has been shown to reduce the concentration of bioaerosols in controlled chambers. However, there is a lack of experimental results on the reduction of bioaerosol concentrations by UVGI devices in actual uncontrolled buildings. This study was carried out in an American elementary school in the Midwest. Two sampling procedures were carried out in six selected classrooms with similar dimensions that were separated into two groups: (1) UVGI exposure group and (2) non-UVGI control group. Two-stage Tisch culturable impactors were utilized to collect airborne culturable bacteria and fungi. Monthly samples were collected during unoccupied period …
Identification Of Key Performance Tasks To Demonstrate The Benefit Of Introducing The Facilities Manager At An Early Stage In The Building Information Modelling Process On Public Sector Projects In Ireland., Barry Mcauley
Doctoral
Modelling (BIM) governed process was investigated in this thesis. Governments are now seeking a more rewarding methodology in the management and procurement of public sector building assets. This has seen an integrated focus by International Governments on BIM as a partial solution in both managing and procuring public sector building assets. Despite BIM bringing the Facility Manager closer to project conceptualisation, there was still a reluctance and a lack of perceived benefits of having them involved earlier in the design phase. There remains a lack of clear evidence on what improved contribution the Facilities Manager can provide. This thesis provides …
Pumping Of Fresh Concrete: Insights And Challenges, Geert De Schutter, Dimitri Feys
Pumping Of Fresh Concrete: Insights And Challenges, Geert De Schutter, Dimitri Feys
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
Pumping of Fresh Concrete is of Utmost Importance for Concrete Practice. Required Pumping Pressures Are Typically Estimated based on Design Charts. However, with the Increased Use of Chemical Admixtures and the Development of More Flowable Concrete Mixtures, the Accuracy of Traditional Design Charts is Questioned. in Recent Years, Significant Progress Has Been Obtained in Understanding the Flow of the Material in the Pumping Pipe, Including the Behavior of the Lubrication Layer Near the Pipe Surface. in Comparison with Traditional Design Charts, This Results in More Reliable Pressure Predictions When Considering Very Fluid Concrete Types Like Self-Consolidating Concrete. Some Remaining Challenges …
A Prediction Method For Overall Economic Value Of Fault Detection And Diagnostic Tools For Rooftop And Split Systems, David Yuill, James Braun
A Prediction Method For Overall Economic Value Of Fault Detection And Diagnostic Tools For Rooftop And Split Systems, David Yuill, James Braun
Durham School of Architectural Engineering and Construction: Faculty Publications
Fault detection and diagnostics (FDD) tools for air-conditioning application may perform well or poorly, but it is difficult to characterize this performance in a meaningful way. Some recently proposed evaluation techniques have provided various statistics to characterize FDD performance, but these results can be difficult for a potential adopter of FDD to understand. A new method of characterizing FDD performance by predicting the overall economic value of the FDD tool is proposed in this paper. It is applicable to FDD tools intended for air-cooled unitary airconditioners, such as rooftop units (RTU) and split systems. The method gives an estimated dollar …
Fault Detection And Diagnosis Process For Oversizing Design On Multiple Packaged Air-Conditioning Units, Denchai Woradechjumroen, Haorong Li, Thanapat Promwattanapakee
Fault Detection And Diagnosis Process For Oversizing Design On Multiple Packaged Air-Conditioning Units, Denchai Woradechjumroen, Haorong Li, Thanapat Promwattanapakee
Durham School of Architectural Engineering and Construction: Faculty Publications
Heating, ventilation, air-conditioning and Refrigeration (HVAC&R) systems are seldom designed or commissioned properly. The situation leads to abrupt or degradation faults resulting in inefficient energy uses, excessive energy consumption and high service costs. To solve these aforementioned problems, fault detection and diagnosis (FDD) is utilized to firstly detect any abnormal conditions of a system and then diagnoses and determines their causes. In order to apply this concept in HVAC oversizing designs, this paper proposes the state-of-art procedure of a FDD procedure for analyzing the inherently faulty design (oversizing) of multiple packaged air-conditioning units used to supply cooling for an open …
Compressor Having A Control And Dagnostic Module, Hung M. Pham, Fadi M. Alsaleem
Compressor Having A Control And Dagnostic Module, Hung M. Pham, Fadi M. Alsaleem
Durham School of Architectural Engineering and Construction: Faculty Publications
An apparatus includes a Voltage sensor, a current sensor, and a controller. The Voltage sensor measures Voltage values of alternating current power Supplied to a capacitor. The capaci tor is electrically coupled to a compressor. The current sensor measures current values of the alternating current power. The controller is configured to receive the Voltage values and the current values. The controller is configured to determine a first power factor value based on at least one of the voltage values and at least one of the current values. The controller is configured to selectively detect a first capacitor fault in response …
An Introduction To The Special Issue On Geoscience Papers Of The Future, Cédric H. David, Yolanda Gil, Christopher J. Duffy, Scott D. Peckham, S. Karan Venayagamoorthy
An Introduction To The Special Issue On Geoscience Papers Of The Future, Cédric H. David, Yolanda Gil, Christopher J. Duffy, Scott D. Peckham, S. Karan Venayagamoorthy
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
Advocates of enhanced quality for published scientific results are increasingly voicing the need for further transparency of data and software for scientific reproducibility. However, such advanced digital scholarship can appear perplexing to geoscientists that are seduced by the concept of open science yet wonder about the exact mechanics and implications of the associated efforts. This special issue of Earth and Space Science entitled "Geoscience Papers of the Future" includes a review of existing best practices for digital scholarship and bundles a set of example articles that share their digital research products and reflect on the process of opening their scientific …
Thermal Envelope Analysis Of Local Authority Low Rise Housing Based On Stock Aggregation Theory Using A Remote Feature Extraction Technique., James Pittam
Theses
Understanding the buildings thermal envelope is paramount to analysing existing problems which facilitate cold bridging and low surface temperatures. As no detailed housing stock database is in existence in Ireland which describes the geometrical configuration of the existing housing stock, and to create one would be a major challenge, this research set out to develop a high speed remote cataloguing and geometrical data extraction methodology to build such a database. Replacing traditional measurement methods with a remote method allows for the rapid extraction of fagade information. A remote surveying process is proposed named, the Virtual Survey Method, for the classification …
Energy-Saving Occupant Behaviour In Offices: Change Strategies, Mark Mulville, Keith Jones, Gesche Huebner, Joanne Powell-Grieg
Energy-Saving Occupant Behaviour In Offices: Change Strategies, Mark Mulville, Keith Jones, Gesche Huebner, Joanne Powell-Grieg
Articles
As regulated energy consumption in buildings is reduced, the proportional importance of unregulated energy consumption increases. Reducing unregulated energy use in the commercial office requires an understanding of the factors that influence workplace behaviour. To date these factors have been assumed to be similar to those that influence behaviour in the home. However, the social dynamics of the workplace are different to those in the home. This study examines the degree to which theories of behaviour change generated largely in a domestic building setting could be used as the basis for designing interventions to reduce unregulated energy consumption in the …
The Space Between The Notes: Reflections On A Collaborative Student Project On The Work Of Irish Engineer Peter Rice, Jim Roche
Conference papers
Abstract
This paper is a reflection on a collaborative pedagogic process at the Dublin School of Architecture (DSA), Technological University Dublin, on aspects of the work of Irish engineer Peter Rice (1935–92) who, in his short life, combined contemporary tools of computer-analysis and mathematics with a careful sensibility for materials, natural light and structure. He collaborated with many famous architectural practices on what have now become iconic works of architecture such as the Sydney Opera House, the Centre Pompidou, Lloyds of London and Kansai Airport. The collaborative project on his work was undertaken at DSA in the fall semester of …
Properties Of Self-Compacting Concrete With Recycled Coarse Aggregate, W. C. Tang, P. C. Ryan, H. Z. Cui, W. Liao
Properties Of Self-Compacting Concrete With Recycled Coarse Aggregate, W. C. Tang, P. C. Ryan, H. Z. Cui, W. Liao
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
The utilization of recycled concrete aggregate (RCA) in Self-Compacting Concrete (SCC) has the potential to reduce both the environmental impact and financial cost associated with this increasingly popular concrete type. However, to date limited research exists exploring the use of coarse RCA in SCC. The work presented in this paper seeks to build on the existing knowledge in this area by examining the workability, strength, and fracture properties of SCCs containing 0%, 25%, 50%, 75%, and 100% coarse RCA. The experimental programme indicated that at RCA utilization levels of 25% to 50% little or no negative impact was observed for …
Analysis Of The Cost Effectiveness Of Combined Particle And Activated Carbon Filters For Indoor Ozone Removal In Buildings, Josh R. Aldred, Erin Darling, Glenn Morrison, Jeffrey Siegel, Richard L. Corsi
Analysis Of The Cost Effectiveness Of Combined Particle And Activated Carbon Filters For Indoor Ozone Removal In Buildings, Josh R. Aldred, Erin Darling, Glenn Morrison, Jeffrey Siegel, Richard L. Corsi
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
This study involved the development of a model for evaluating the potential costs and benefits of ozone control with combined particle/activated carbon filtration (referred to here as activated carbon filtration) in buildings. The modeling effort included the prediction of indoor ozone and ozone reaction products with and without activated carbon filtration in the HVAC system. Benefitto- cost ratios were estimated for various types of buildings in 12 American cities in 5 different climate zones. Health benefits were evaluated using disability-adjusted life-years attributed to the difference in indoor ozone concentration with and without activated carbon filtration and included city-specific age demographics …
Geotechnical State-Of-The-Art In Guatemala -- Ground Stabilization, Fernando Rafael Callejas Benitez
Geotechnical State-Of-The-Art In Guatemala -- Ground Stabilization, Fernando Rafael Callejas Benitez
Doctoral Dissertations
"History provides an understanding of the present and in a way, a guide for the future. The state-of-the-art is often referred to as a snapshot of the most significant works and contributions made in a field of study; In this case the focus is on Guatemalan geotechnical engineering. This study presents a comprehensive description of the different events that impulse geotechnical engineering in Guatemala.
As part of the description of the state-of-the-practice an investigation of the different human (engineers/contractors) and physical resources (laboratories/field equipment) and their capabilities are presented. An overview of the civil engineering programs is presented. Then, the …
Influence Of The Substrate Characteristics On The Bond Behavior Of Pbo Frcm-Concrete Joints, Tommaso D'Antino, Lesley H. Sneed, Christian Carloni, Carlo Pellegrino
Influence Of The Substrate Characteristics On The Bond Behavior Of Pbo Frcm-Concrete Joints, Tommaso D'Antino, Lesley H. Sneed, Christian Carloni, Carlo Pellegrino
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
Fiber Reinforced Cementitious Matrix (FRCM) composites can be employed as a valid alternative to Fiber Reinforced Polymers (FRP) composites for strengthening existing reinforced concrete (RC) structures. The weakness of FRCM-concrete joints has been reported to be at the matrix-fiber interface rather than within the concrete substrate, as is usually reported in the case of FRP-concrete joints. The experimental investigations regarding FRCM strengthening available in the literature have been performed by applying the FRCM composite onto a surface that was treated before the application, usually by grinding or sandblasting. However, the role of the substrate characteristics on the failure mechanism of …
Dispute Resolution Under The Principal Irish Forms Of Building Contract, Tony Cunningham
Dispute Resolution Under The Principal Irish Forms Of Building Contract, Tony Cunningham
Other Resources
The construction industry is known to be litigious (Latham, 1994). This is hardly surprising given the industry’s fragmented nature in which project teams comprising an extensive network of employers, designers and constructors are brought together to deliver once-off projects, following which, the organisation is almost always disbanded. The short term objectives of the various groupings are often competing and occasionally incompatible. For example, many employers will wish to minimise costs in developing a project, designers may resist pressures on budgets in order to safeguard their ‘brand’, and the commercial imperative of maximising profit will drive contractors towards charging what the …
Risk Allocation Under The Principal ‘Traditional’ Irish Forms Of Building Contract, Tony Cunningham
Risk Allocation Under The Principal ‘Traditional’ Irish Forms Of Building Contract, Tony Cunningham
Other Resources
Construction projects are risky ventures. Risks are inevitable and cannot be entirely eliminated but they can be transferred through appropriate wording in the clauses of a contract. Construction contracts allocate particular risks between the parties in order to identify who bears the cost if a particular risk comes to pass.
This study examines how contractual risks are allocated to the contracting parties under the Royal Institute of Architects in Ireland Form, 2012 version, where quantities form part of the contract, commonly known as ‘the Yellow Form’, and the Public Works Contract PW CF1 Form v 1.10, 2014 where the design …