Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Corrosion

Discipline
Institution
Publication Year
Publication
Publication Type
File Type

Articles 421 - 450 of 682

Full-Text Articles in Entire DC Network

Caves In Caves: Evolution Of Post-Depositional Macroholes In Stalagmites, Nurit Shtober-Zisu, Henry P. Schwarcz, Tom Chow, Christopher R. Omelon, Gordon Southam Sep 2014

Caves In Caves: Evolution Of Post-Depositional Macroholes In Stalagmites, Nurit Shtober-Zisu, Henry P. Schwarcz, Tom Chow, Christopher R. Omelon, Gordon Southam

International Journal of Speleology

In a previous paper (Shtober-Zisu et al., 2012) we described millimeter to centime-sized fluid-free holes within the interiors of stalagmites of widely varying origin. We present here further observations of this phenomenon, using X-ray tomography, macroscopic and microscopic observation of sections of twenty-six stalagmites from various sites in North America and the Caribbean region. We can distinguish three types of cavities in speleothems: primary µm-sized fluid inclusions; mm to cm sized holes, aligned along the stalagmite growth axis which are clearly syngenetic; and µm to cm-sized holes away from the growth axis (“off-axis holes or OAHs”) deeply buried inside their …


Reversing Sensitization Of Naturally Exfoliated 5456-H116 Aluminum Alloys, Ren-Yu Chen, Cheng-Chyuan Lai Aug 2014

Reversing Sensitization Of Naturally Exfoliated 5456-H116 Aluminum Alloys, Ren-Yu Chen, Cheng-Chyuan Lai

Journal of Marine Science and Technology–Taiwan

5456-H116 Al-Mg alloy has been broadly used in the U.S. Navy in order to meet the demand of reducing ship hull weight while considering high specific strength, corrosion resistance, and weldability. A particular concern of these alloy is sensitization, which causes it to be sensitized when highly anodic β phase (Al3Mg2) is precipitated at grain boundaries especially in service exceeding 65~200°C, leading to intergranular corrosion (IGC), exfoliation and stress corrosion cracking (SCC). This study investigated the reversal of sensitization of a naturally exfoliated 5456-H116 alloy plate by planned heating treatment with a short exposure to 250°C. The properties of sensitized …


An Evolutionary Polynomial Regression (Epr) Model For Prediction Of H2s Induced Corrosion In Concrete Sewer Pipes, Anna Romanova, Asaad Faramarzi, Mojtaba Mahmoodian, M. Amir Alani Aug 2014

An Evolutionary Polynomial Regression (Epr) Model For Prediction Of H2s Induced Corrosion In Concrete Sewer Pipes, Anna Romanova, Asaad Faramarzi, Mojtaba Mahmoodian, M. Amir Alani

International Conference on Hydroinformatics

The sulphuric acid is a known growing threat to concrete sewer pipes. Acid production is dictated by rapid urbanisation, increased use of hot water and discharge of toxic metals and sulphate containing detergents into the wastewater. Concrete sewer pipe corrosion due to sulphuric attack is known to be the main contributory factor of pipe degradation. Very little tools are available to accurately predict the corrosion rate and most importantly the remaining safe life of the asset. This paper proposes a new robust model to predict the sewer pipe corrosion rate due to sulphuric acid. The model makes use of a …


A Rubric For Electrochemical Testing Of Metallic Biomaterials, Frederick G. De La Fuente Aug 2014

A Rubric For Electrochemical Testing Of Metallic Biomaterials, Frederick G. De La Fuente

Master's Theses

Corrosion is a major factor for the failure of metallic medical implants. Testing a metal’s suseptability to corrosion prior to implantation is key to a successful implantation. Electrochemical processes were used in this study to evaluate the characteristics of corrosion of both AISI 316 stainless steel and titanium alloy Ti6Al4V, welded and non-welded. Linear, potentiodynamic, and cyclic polarization curves were produced by the PARC 2273 potentiostat showing the corrosion tendencies of the metals in four unique solutions 3.5% NaCl, 0.35% NaCl, phosphate buffered saline solution (PBS), and Butterfield phosphate buffered solution (BPS). The concentration of chloride ions in solutions affected …


Prediction Of Corrosion-Induced Crack Width Of Corroded Reinforced Concrete Structures, Jin Xia, Wei-Liang Jin Jul 2014

Prediction Of Corrosion-Induced Crack Width Of Corroded Reinforced Concrete Structures, Jin Xia, Wei-Liang Jin

International Conference on Durability of Concrete Structures

This paper presents an experimental investigation on the crack width induced by the corrosion of reinforcing steel bars in concrete. Reinforcing steel bars with different diameters were corroded using an accelerated test in three types of concrete members, including 24 beams with corroded stirrup and 20 beams with corroded longitudinal reinforcing steel bars. The corrosion patterns and rusts characteristics of the corroded steel bars were examined and compared with those observed in real RC structures. According to the experimental result, the corrosioninduced crack width were analyzed and showed a linear relationship with the corrosion loss of reinforcing steel bar. Finally, …


Feasibility Of Application Of Cathodic Prevention To Cracked Reinforced Concrete In Marine Service, Kevin Williams Jul 2014

Feasibility Of Application Of Cathodic Prevention To Cracked Reinforced Concrete In Marine Service, Kevin Williams

USF Tampa Graduate Theses and Dissertations

Corrosion can take place as chloride ions accumulate above a critical concentration (CT) at the surface of a reinforcing bar inside concrete in marine service. The initiation of corrosion can be delayed by polarizing the steel cathodically, which is known to increase the value of CT. That effect is the basis of the cathodic prevention (CPrev) method to control corrosion of reinforcing steel in concrete. However, concrete cracks are a common occurrence and at cracks, the buildup of chloride ions is accelerated to the extent that CPrev may be less effective. The findings from an ongoing investigation to determine the …


Mineralogical Transformation And Electrochemical Nature Of Magnesium-Rich Primers During Natural Weathering, Shashi S. Pathak, Michael D. Blanton, Sharathkumar K. Mendon, James W. Rawlins Jul 2014

Mineralogical Transformation And Electrochemical Nature Of Magnesium-Rich Primers During Natural Weathering, Shashi S. Pathak, Michael D. Blanton, Sharathkumar K. Mendon, James W. Rawlins

Faculty Publications

Magnesium-rich primers (MgRP) have generated great interest as a promising alternative to chromium-based primers for the protection of aluminum substrates but their performance during exterior exposure has not been well documented. This paper focuses on the evaluation of MgRP during natural weathering to gain insight into its mineralogical phase transformation and electrochemical nature. Control studies were conducted on Mg and AA2024-T3 coupons. The results indicate that Mg particles in MgRP transform into a variety of hydroxide, carbonate, and hydroxy carbonates. During natural weathering, CO2 inhibited the dissolution of both Mg and AA2024-T3 as a result of protective carbonate layer …


Composition, Phase Structure, And Corrosion Of Nickel-Free And Nickel-Containing Stainless Steel Orthodontic Wires, Amrita Rakalla Jul 2014

Composition, Phase Structure, And Corrosion Of Nickel-Free And Nickel-Containing Stainless Steel Orthodontic Wires, Amrita Rakalla

Master's Theses (2009 -)

Stainless steel wires have long been used in orthodontics. The austenitic stainless steel used in orthodontics contains approximately 18 wt% chromium and 8 wt% nickel. Nickel improves the corrosion resistance and helps maintain the austenite structure of stainless steel. Nickel is the most allergenic metal and is the most common metal associated with contact dermatitis in orthodontics. Nickel-free wires have been developed, and it was the goal of this study to compare nickel-free and nickel-containing stainless steel orthodontic wires to determine and compare their composition, phase structure, and corrosion properties. For each test, nickel-free and conventional stainless steel wires were …


Friction Bit Joining Of Dissimilar Combinations Of Advanced High-Strength Steel And Aluminum Alloys, Lile P. Squires Jun 2014

Friction Bit Joining Of Dissimilar Combinations Of Advanced High-Strength Steel And Aluminum Alloys, Lile P. Squires

Theses and Dissertations

Friction bit joining (FBJ) is a new method that enables lightweight metal to be joined to advanced high-strength steels. Weight reduction through the use of advanced high-strength materials is necessary in the automotive industry, as well as other markets, where weight savings are increasingly emphasized in pursuit of fuel efficiency. The purpose of this research is twofold: (1) to understand the influence that process parameters such as bit design, material type and machine commands have on the consistency and strength of friction bit joints in dissimilar metal alloys; and (2) to pioneer machine and bit configurations that would aid commercial, …


Electrochemical-Mechanistic Model For Concrete Cover Cracking Due To Corrosion Initiated By Chloride Diffusion, Goli Nossoni, Ronald S. Harichandran Jun 2014

Electrochemical-Mechanistic Model For Concrete Cover Cracking Due To Corrosion Initiated By Chloride Diffusion, Goli Nossoni, Ronald S. Harichandran

Civil Engineering Faculty Publications

A holistic electrochemical-mechanistic model of the corrosion of steel reinforcing bars inside concrete that accounts for the diffusion of oxygen and moisture into the concrete and rust layers, the densification of rust due to confinement, the flow of rust into the concrete pores, the development of internal pressure due to rust buildup, and cracking of the concrete cover is presented. The relationship between the corrosion current and the pressure buildup due to the corrosion products for different concrete cover thicknesses and concrete quality was calibrated through experiments using an accelerated corrosion test with an applied current. Results from finite-element analysis …


Flexural Behavior Of Reinforced Concrete T-Beams Strengthened With Nsm Composite System Under Accelerated Corrosion., Anes Bouchair Jun 2014

Flexural Behavior Of Reinforced Concrete T-Beams Strengthened With Nsm Composite System Under Accelerated Corrosion., Anes Bouchair

Theses

This research work aims at evaluating the effects of corrosion on flexural response of simply supported reinforced concrete (RC) T-Beams strengthened with near-surface-mounted carbon fiber-reinforced polymer (NSM-CFRP) strips. The research comprised experimental testing and analytical modelling. Test parameters included concrete grade, amount of NSM-CFRP strips, presence of U-wraps along the beam span, and time of corrosion exposure. A total of eighteen reinforced concrete beams with a T-shaped cross section were tested. Fourteen beams were strengthened in flexure and four beams were not strengthened to act as benchmarks. The strengthening regime included installation of either two or four NSM-CFRP strips into …


Corrosion Assessment And Enhanced Biocompatibility Analysis Of Biodegradable Magnesium-Based Alloys, Luis Enrique Pompa May 2014

Corrosion Assessment And Enhanced Biocompatibility Analysis Of Biodegradable Magnesium-Based Alloys, Luis Enrique Pompa

Theses and Dissertations - UTB/UTPA

Magnesium alloys have raised immense interest to many researchers because of its evolution as a new third generation material. Due to their biocompatibility, density, and mechanical properties, magnesium alloys are frequently reported as prospective biodegradable implant materials. Moreover, magnesium based alloys experience a natural phenomena to biodegrade in aqueous solutions due to its corrosive activity, which is excellent for orthopedic and cardiovascular applications. However, major concerns with such alloys are fast and non-uniform corrosion degradation. Controlling the degradation rate in the physiological environment determines the success of an implant. In this investigation, three grades of magnesium alloys: AZ31B, AZ91E and …


Influence Of Surface Modification On Corrosion And Biocompatibility Of Titanium Alloys, Zia Ur Rahman May 2014

Influence Of Surface Modification On Corrosion And Biocompatibility Of Titanium Alloys, Zia Ur Rahman

Theses and Dissertations - UTB/UTPA

Titanium alloys enhance the quality and longevity of human life by replacing or treating various parts of the body. However, the aggressive body fluids lead to corrosion and metal ions dissolution. These ions leach to the adjacent tissues and causes adverse reactions. Surface modifications improve corrosion resistance and biological activity. In this investigation, electropolishing, magnetoelectropolishing, titanium coating and hydroxyapatite coating were carried out on commercially pure titanium (CPTi), Ti6Al4V and Ti6Al4V-ELI (Extra Low Interstitials). These surface modifications are known to affect surface chemistry, morphology, wettability, corrosion resistance and biocompatibility of these materials. In vitro cyclic potentiodynamic polarization tests were conducted …


In Vitro Immersion Behavior Of Cold Sprayed Hydroxyapatite/Titanium Composite Coatings, Lin Lu, Xuan Joe Zhou, Pravansu Mohanty Apr 2014

In Vitro Immersion Behavior Of Cold Sprayed Hydroxyapatite/Titanium Composite Coatings, Lin Lu, Xuan Joe Zhou, Pravansu Mohanty

Electrical & Computer Engineering Publications

In previous study, dense and homogenous 20wt% HAP/Ti composite coatings were successfully deposited on Ti substrates by cold gas dynamic spray technique. The results revealed that the phase composition of the HAP in the deposit is identical to that of the precursor powder and the bonding strength of the deposit is comparable/better to that of the plasma sprayed HAP. A relatively higher corrosion current of HAP/Ti composite than that of pure Ti coating in simulated body fluid indicates a good bioactivity for composite coating. In the present study, in vitro immersion test is carried out for various period of time …


In Situ Detection On Electrochemical Chloride Removal Of Reinforcement In Concrete By Combined Ph/Cl- Probes, Jing-Jing Wang, Shi-Gang Dong, Xiao-Juan Zhang, Hong-Wei Lv, Yun-Chang Wu, Rong-Gui Du, Chang-Jian Lin Apr 2014

In Situ Detection On Electrochemical Chloride Removal Of Reinforcement In Concrete By Combined Ph/Cl- Probes, Jing-Jing Wang, Shi-Gang Dong, Xiao-Juan Zhang, Hong-Wei Lv, Yun-Chang Wu, Rong-Gui Du, Chang-Jian Lin

Journal of Electrochemistry

In this work, the concrete samples polluted by chloride ion were electrochemically treated using galvanostatic technique, and the distributions of chloride ion concentration and pH value in the polluted concretes were in-situ monitored by embedding a combined pH/Cl- probe during the electrochemical chloride removal. The corrosion behaviors of reinforcing steel in the concrete were simultaneously studied by using linear polarization and electrochemical impedance spectroscopy techniques (EIS). The micro environment of the concrete and corrosion rate of steel were explored during the electrochemical chloride removal. It was indicated that the Cl- concentration in the concrete pore solution decreased with …


Sensitivity Of Electrochemical Impedance Spectroscopy Measurements To Concrete Bridge Deck Properties, Hillary Mckenna Argyle Mar 2014

Sensitivity Of Electrochemical Impedance Spectroscopy Measurements To Concrete Bridge Deck Properties, Hillary Mckenna Argyle

Theses and Dissertations

Numerous methods have been developed to measure corrosion potential relating to chloride infiltration in concrete, including an emerging application of electrochemical impedance spectroscopy (EIS). EIS involves measurements of electrical impedance to evaluate the corrosion potential of steel reinforcement in concrete. With EIS, current is injected vertically into the concrete bridge deck between the surface and the embedded reinforcing steel, usually the top mat, to evaluate the degree to which the reinforcing steel is protected from chloride infiltration by the entire bridge deck system. The objectives of this research were to 1) investigate the sensitivity of EIS measurements obtained at various …


Development Of A Chloride Concentration Sampling Protocol For Concrete Bridge Decks, Sharlan Renae Montgomery Mar 2014

Development Of A Chloride Concentration Sampling Protocol For Concrete Bridge Decks, Sharlan Renae Montgomery

Theses and Dissertations

As the primary cause of concrete bridge deck deterioration in the United States is corrosion of the steel reinforcement as a result of the application of chloride-based deicing salts, chloride concentration testing is among the most common techniques for evaluating the condition of a concrete bridge deck. The objectives of this research were to 1) compare concrete drilling and powder collection techniques to develop a sampling protocol for accurately measuring chloride concentrations and 2) determine the number of chloride concentration test locations necessary for adequately characterizing the chloride concentration of a given bridge deck. Laboratory experiments on concrete drilling and …


Phosphate-Doped Borosilicate Enamel Coating Used To Protect Reinforcing Steel From Corrosion, Xiaoming Cheng Jan 2014

Phosphate-Doped Borosilicate Enamel Coating Used To Protect Reinforcing Steel From Corrosion, Xiaoming Cheng

Doctoral Dissertations

"Phosphate-doped sodium borosilicate glasses were developed for enamel coatings to provide corrosion protection for reinforcing steel in concrete. Phosphates have low solubilities in borosilicate glasses, generally less than about 4 mol%, and are incorporated mainly as isolated PO43- and P2O74- anions, along with some borophosphate bonds. With the addition of P2O5, the silicate network is repolymerized and tetrahedral borates are converted to trigonal borates, because the phosphate anions scavenge sodium ions from the borosilicate network. The addition of Al2O3 significantly increases the solubility of P2O …


Magnesium-Titanium Alloys For Biomedical Applications, Ilona Hoffmann Jan 2014

Magnesium-Titanium Alloys For Biomedical Applications, Ilona Hoffmann

Theses and Dissertations--Chemical and Materials Engineering

Magnesium has been identified as a promising biodegradable implant material because it does not cause systemic toxicity and can reduce stress shielding. However, it corrodes too quickly in the body. Titanium, which is already used ubiquitously for implants, was chosen as the alloying element because of its proven biocompatibility and corrosion resistance in physiological environments. Thus, alloying magnesium with titanium is expected to improve the corrosion resistance of magnesium.

Mg-Ti alloys with a titanium content ranging from 5 to 35 at.-% were successfully synthesized by mechanical alloying. Spark plasma sintering was identified as a processing route to consolidate the alloy …


Corrosion Prevention And Control Training In An Immersive Virtual Learning Environment, Rustin Deane Webster Jan 2014

Corrosion Prevention And Control Training In An Immersive Virtual Learning Environment, Rustin Deane Webster

All ETDs from UAB

The majority of military education and training has not veered far from the days of chalk and talk instruction. Often with technological breakthroughs comes the proposal of the next revolution in multimedia instruction. Motion pictures to radios to educational television programs have all seemed to come and gone. The next wave of multimedia learning may involve more than a PowerPoint® presentation and lecture. Researchers continue to propose that Virtual Reality (VR) will find its true application and/or market in education and training. The objective of the project was to develop and provide a low-cost, scalable, and portable VR system containing …


Multi-Phase Modelling Of Multi-Species Ionic Migration In Concrete, Qingfeng Liu Jan 2014

Multi-Phase Modelling Of Multi-Species Ionic Migration In Concrete, Qingfeng Liu

Other Faculty of Science and Engineering Theses

Chloride-induced corrosion of reinforcing steel in concrete is a worldwide problem. In order to predict how chlorides penetrate in concrete and how other ionic species in con-crete pore solution affect the penetration of chlorides, this thesis presents a numerical study on multi-phase modelling of ionic transport in concrete dominated by migration process. There are many advantages in rapid chloride migration test (RCM) method and numeri-cal approach. However, most of models in the literature predicting chloride diffusivity in concrete are diffusion models, which not consider the action of externally applied electric field. In view of this, the specific aim of this …


Fabrication And Enhancement Of Aluminum-Based Microchannel Devices, Paul Joseph Hymel Jan 2014

Fabrication And Enhancement Of Aluminum-Based Microchannel Devices, Paul Joseph Hymel

LSU Master's Theses

Microscale molding replication and transient liquid phase (TLP) bonding were used to fabricate Al-based microchannel heat exchangers (MHEs) and micro gas chromatograph (mGC) columns. Metal-based microchannel heat exchangers often experience corrosion as a result of their operating conditions. To address this problem, an internal anodization method was developed in Al microtubes by pulsing the flow of electrolyte through a microtube when the current dropped below a set value. The anodic aluminum oxide (AAO) films were characterized by scanning electron microscopy (SEM), focused ion beam (FIB) cross sections, and X-ray energy dispersive spectroscopy (EDS) to determine their growth rate and morphology. …


Delamination Detection In Concrete Using Disposable Impactors For Excitation, Anjali Narendra Patil Dec 2013

Delamination Detection In Concrete Using Disposable Impactors For Excitation, Anjali Narendra Patil

Theses and Dissertations

Delaminations in concrete bridge decks result primarily from corrosion of the reinforcing bars (or rebar). This corrosion leads to volumetric expansion of the rebar. When the rebar expands, concrete cracks, and there is a localized separation of the concrete cover from the underlying concrete. Impact-echo testing is an effective technique to map delaminations on concrete bridge decks. However, mapping speed is limited by necessary retrieval of the impactor for traditional tests. To achieve higher scanning speeds, it is advantageous to use both a non-contact measurement (air-coupled impact-echo) and disposable-impactor excitation. Disposable impactors have the potential advantage of achieving greater deck …


Creation Of An Internal State Variable Plasticity-Damage-Corrosion Model Validated By Experiments With Magnesium Alloys, Christopher Avery Walton Dec 2013

Creation Of An Internal State Variable Plasticity-Damage-Corrosion Model Validated By Experiments With Magnesium Alloys, Christopher Avery Walton

Theses and Dissertations

In this study, a new consistent formulation coupling kinematics, thermodynamics, and kinetics with damage using an extended multiplicative decomposition of the deformation gradient that accounts for corrosion effects is presented. The technical approach used for modeling the corrosion behavior of magnesium alloys was divided into three primary steps. First, a predictive corrosion model was developed based on experimental corrosion observations. The experimentally-observed corrosion mechanisms of pitting, intergranular, and general corrosion on the AZ31 magnesium alloy were quantified in 3.5 wt.% NaCl immersion and salt spray environments using optical microscopy and laser profilometry to document the changes in the pit characteristics. …


Basic Principles And Applications Of Secm In Metal Corrosion, Fa-He Cao, Yan Xia, Wen-Juan Liu, Lin-Rong Chang, Jian-Qing Zhang Oct 2013

Basic Principles And Applications Of Secm In Metal Corrosion, Fa-He Cao, Yan Xia, Wen-Juan Liu, Lin-Rong Chang, Jian-Qing Zhang

Journal of Electrochemistry

Scanning electrochemical microscopy (SECM) is chemical microscopy with higher spatial resolution. After 24 years of development, SECM has been widely applied in mapping and kinetics study of heterogeneous electron transfer in localized processes at solid-liquid or liquid-liquid interfaces. The fundamentals and recent advances of SECM in corrosion applications are described, including SECM mapping and kinetics on localized corrosion of metal or coating. Research work of SECM in corrosion by our group is also introduced. Future applications of SECM in corrosion are highlighted.


Applications Of Spectroscopic Ellipsometry In Corrosion Investigation, Ling-Jie Li, Yu-Ling He, Jing-Lei Lei, Sheng Tao Zhang Oct 2013

Applications Of Spectroscopic Ellipsometry In Corrosion Investigation, Ling-Jie Li, Yu-Ling He, Jing-Lei Lei, Sheng Tao Zhang

Journal of Electrochemistry

As a highly-sensitive and non-destructive in situ technique, spectroscopic ellipsometry has been widely applied in corrosion investigation to acquire the dynamic information of the “electrode-medium” interface during corrosion. This paper lays out some representative demonstrations in several established optical models used to interpret data obtained with spectroscopic ellipsometry in corrosion investigation. In addition, the latest trends in development of this technique are analyzed.


Iron-Magnesium Alloy Bioabsorbable Blood Stent, Kaitlyn Jarry, L Stanciu Oct 2013

Iron-Magnesium Alloy Bioabsorbable Blood Stent, Kaitlyn Jarry, L Stanciu

The Summer Undergraduate Research Fellowship (SURF) Symposium

Bioabsorbable materials are fairly new and proper alloys for implantation in the body have not yet been established. There are a few polymers that have showed promise, but they do not provide the proper mechanical support that metal does. These materials would be used to create devices such as blood stents and orthopedic screws. Investigation into the properties of different alloys can help to establish a material that can be used for implanted devices that are only needed for a limited amount of time. In order to investigate these alloys many different experiments will to be run to test the …


Influence Of Copper And Mild Steel On Stability Of Palm Biodiesel, M.R. Jakeria, M.A. Fazal, A.S. Md. Abdul Haseeb Oct 2013

Influence Of Copper And Mild Steel On Stability Of Palm Biodiesel, M.R. Jakeria, M.A. Fazal, A.S. Md. Abdul Haseeb

Research Publications (2011 to 2015)

Fossil fuel depletion has caused a serious concern, which has promoted the search for alternative energy source. Use ofbiodiesel has recently been proven as a potential source of energy. However, commercial use of higher blends of biodiesel in automobiles is being questionable because of its unstable fuel properties. The present study aims to investigate stability of different fuel properties of palm biodiesel upon exposure to copper and mild steel, which are exposed to biodiesel in automobile engines. Static immersion tests were conducted by exposing metallic coupons in palm biodiesel at room temperature for different periods viz., 20, 40, 60 days. …


Self-Potential Signals Generated By The Corrosion Of Buried Metallic Objects With Application To Contaminant Plumes, Justin B. R. Rittgers, Andre Revil, Marios C. Karaoulis, Michael A. Mooney, Lee D. Slater, Estella A. Atekwana Sep 2013

Self-Potential Signals Generated By The Corrosion Of Buried Metallic Objects With Application To Contaminant Plumes, Justin B. R. Rittgers, Andre Revil, Marios C. Karaoulis, Michael A. Mooney, Lee D. Slater, Estella A. Atekwana

Geosciences and Geological and Petroleum Engineering Faculty Research & Creative Works

Large-amplitude (>100 mV) negative electric (self)-potential anomalies are often observed in the vicinity of buried metallic objects and ore bodies or over groundwater plumes associated with organic contaminants. To explain the physical and chemical mechanisms that generate such electrical signals, a controlled laboratory experiment was carried out involving two metallic cylinders buried with vertical and horizontal orientations and centered through and in the capillary fringe within a sandbox. The 2D and 3D self-potential (SP) data were collected at several time steps along with collocated pH and redox potential measurements. Large dipolar SP and redox potential anomalies developed in association …


Advances In Mg Corrosion And Research Suggestions, Andrej Atrens, Guang Ling Song, Fuyong Cao, Zhiming Shi, Patrick K. Bowen Sep 2013

Advances In Mg Corrosion And Research Suggestions, Andrej Atrens, Guang Ling Song, Fuyong Cao, Zhiming Shi, Patrick K. Bowen

Michigan Tech Publications, Part 1

Recent research is summarised with an emphasis on the use of Mg alloys for biodegradable medical applications. Mg melt purification using Zr has been shown to provide the opportunity to produce ultra-high-purity Mg alloys, which could lead to stainless Mg. Nor's solution may be a good starting model for the study of Mg for biodegradable medical implant applications. A systematic laboratory investigation is needed to elucidate the details of how the corrosion behaviour is controlled by the various constituents of the body fluids.

In the evaluation of the Mg corrosion mechanism there is a critical lack of understanding of (i) …