Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

2007

Discipline
Institution
Keyword
Publication
Publication Type

Articles 211 - 240 of 882

Full-Text Articles in Entire DC Network

Observation Of An Isokinetic Temperature And Compensation Effect For High Temperature Crude Oil Fouling, C. A. Bennett, R. S. Kistler, K. Nangia, W. Al-Ghawas, N. Al-Hajji, A. Al-Jemaz Jul 2007

Observation Of An Isokinetic Temperature And Compensation Effect For High Temperature Crude Oil Fouling, C. A. Bennett, R. S. Kistler, K. Nangia, W. Al-Ghawas, N. Al-Hajji, A. Al-Jemaz

Heat Exchanger Fouling and Cleaning VII

The initial fouling rates of four crude oils were determined at a nominal bulk temperature of 315 °C, an initial heated wall shear stress of 13 Pa, and initial surface temperatures between 375 and 445 °C. These initial fouling rates ranged from 1.3(10-6) to 7.8(10-5) m2 K/kJ. Corresponding Arrhenius plots were linear with the initial fouling rates passing through an isokinetic temperature of 407.5 °C. A plot of the natural logarithm of the preexponential factors (7.6(104) – 5.2(1015) m2 K/kJ) versus the apparent activation energies (128 – 269 kJ/mol) was also linear, confirming the validity of the isokinetic temperature and …


Investigation Of The Mechanisms Of Heat Exchanger Corrosion In A Municipal Waste Incineration Plant By Analysis Of The Raw Gas And Variation Of Operating Parameters, C. Deuerling, J. Maguhn, H. Nordsieck, B. Benker, R. Zimmermann, R. Warnecke Jul 2007

Investigation Of The Mechanisms Of Heat Exchanger Corrosion In A Municipal Waste Incineration Plant By Analysis Of The Raw Gas And Variation Of Operating Parameters, C. Deuerling, J. Maguhn, H. Nordsieck, B. Benker, R. Zimmermann, R. Warnecke

Heat Exchanger Fouling and Cleaning VII

The detailed mechanism of high temperature chlorine corrosion, the dominant cause of corrosion in a municipal solid waste incinerator (MSI), has still to be clarified (Schroer, 2002). Upon its way through the boiler the raw gas is subject to various physical and chemical processes and interactions. Of these, sulphation of chlorides is supposed to have the major impact on chlorine corrosion (Neumann, 1997). The physical and chemical mechanisms of corrosion were investigated at a municipal solid waste incinerator. Both, the particulate and gas phase of the flue gas, were chemically and physically analyzed during their way through the boiler, at …


The Thermo-Hydrodynamics Of A Concentric Ohmic Heater For Processing Dairy Fluids, H.J. Tham, X.D. Chen, B. Young, B. Bansal, L. Zhang, G. Duffy Jul 2007

The Thermo-Hydrodynamics Of A Concentric Ohmic Heater For Processing Dairy Fluids, H.J. Tham, X.D. Chen, B. Young, B. Bansal, L. Zhang, G. Duffy

Heat Exchanger Fouling and Cleaning VII

The thermo-hydraulic performance of a 300W concentric annular ohmic heater was investigated. To minimize possible electrochemical reactions and corrosion, a higher frequency was applied and factors of field strength and frequency were studied. 2D computer simulation solving momentum, thermal and electrical energy was performed using the FlexPDE software. A good agreement between experimental and analytical analysis of static heating was obtained. There were significant differences between calculated and measured wall temperature near the entrance. The calculated outlet temperature was however in reasonable agreement with the experiment value.


Influence Of Different Surface Materials On Nucleation And Crystal Growth In Heat Exchangers, T. Geddert, S. Kipp, W. Augustin, S. Scholl Jul 2007

Influence Of Different Surface Materials On Nucleation And Crystal Growth In Heat Exchangers, T. Geddert, S. Kipp, W. Augustin, S. Scholl

Heat Exchanger Fouling and Cleaning VII

The influence of different materials on the fouling tendency in saline calcium sulfate solution was investigated. The effects of the untreated material on the crystallization process have been studied experimentally in the micro- and macroscopic scale. The crystallization in the induction period was visualized with SEM and AFM to locate preferred nucleation spots and to visualize the crystal growth. The different materials are showing different crystal growth behavior (number and size of the crystals). These results are corresponding with the macroscopic fouling results with limited shear stress. Also different roughness values on stainless steel have been studied with respect to …


A Real Time Monitoring Model Of The Calcium Carbonate Fouling Induction Period Based On The Conductance Titration, S.R. Yang, S.X. Cao, L.J. Chen, Z.M. Xu, M.L. Yu, W.H. Sun, K.L. Zheng Jul 2007

A Real Time Monitoring Model Of The Calcium Carbonate Fouling Induction Period Based On The Conductance Titration, S.R. Yang, S.X. Cao, L.J. Chen, Z.M. Xu, M.L. Yu, W.H. Sun, K.L. Zheng

Heat Exchanger Fouling and Cleaning VII

A new method has been developed to monitor the calcium carbonate fouling induction period (CCFIP) in real time. Based on the conductance titration, this paper investigated the forming process of CCFIP by a staticdynamic combined simulation experiment unit. With the help of titration analysis (that is titrimetry), an accurate definition of CCFIP and the corresponding real time monitoring model were built up. The investigation results show that the proposed model applies not only to measure the CCFIP in real time, but also applies to an investigation of the influence of various factors on the CCFIP.


Interaction Of Whey Protein With Modified Stainless Steel Surfaces, S.S. Premathilaka, M.M. Hyland, X.D. Chen, L.R. Watkins, B. Bansal Jul 2007

Interaction Of Whey Protein With Modified Stainless Steel Surfaces, S.S. Premathilaka, M.M. Hyland, X.D. Chen, L.R. Watkins, B. Bansal

Heat Exchanger Fouling and Cleaning VII

Modified stainless steel surfaces were fouled with whey protein solutions to study the deposition mechanisms and the effects of surface modification. Stainless steel samples were coated with diamond-like carbon (DLC) and titanium nitride (TiN). These surfaces are expected to present different surface chemistries to stainless steel in terms of their functional groups and hydrophobic or hydrophilic nature. Thus, it is expected that foulant-surface interactions will differ for the various fouled surfaces. The substrates were exposed to a flowing whey protein solution in a fouling rig designed to achieve laminar flow. X-ray Photoelectron Spectroscopy (XPS) was used to study the initial …


Fouling Mechanisms By Ab Initio Calculations Condensation Reactions On The Rutile (101) Surface And Adsorption Of Ions On The Cr2o3 Surfaces, E. Puhakka, M. Riihimäki, R.L. Keiski Jul 2007

Fouling Mechanisms By Ab Initio Calculations Condensation Reactions On The Rutile (101) Surface And Adsorption Of Ions On The Cr2o3 Surfaces, E. Puhakka, M. Riihimäki, R.L. Keiski

Heat Exchanger Fouling and Cleaning VII

Molecular modelling approach was utilized to describe detailed fouling mechanism caused by crystallization. The interest was on the heat transfer surfaces, which were manufactured from titanium and stainless steel. With ab initio calculations, the role of the surface oxide layer structure of titanium and stainless steel on fouling was investigated. The surface structure of titanium and stainless steel were assumed to consist of rutile (TiO2) and dichromium trioxide (Cr2O3), respectively. It was found that the inorganic fouling depends strongly on the oxide layer structure and the existence of hydroxyl groups on the surface. Based on the results, two mechanistically different …


Modelling Of Particulate Fouling On Heat Exchanger Surfaces: Influence Of Bubbles On Iron Oxide Deposition., D.H. Lister, F.C. Cussac Jul 2007

Modelling Of Particulate Fouling On Heat Exchanger Surfaces: Influence Of Bubbles On Iron Oxide Deposition., D.H. Lister, F.C. Cussac

Heat Exchanger Fouling and Cleaning VII

Studies of iron oxide deposition on Alloy-800 heatexchanger tubes have been part of a continuing research program at the University of New Brunswick; the present work formulates mechanisms for the effect of bubbles on deposition in water under boiling conditions. To supplement results from earlier deposition experiments in a fouling loop at UNB, measurements of bubble frequency and departure diameter as a function of heat flux were performed. High-speed movies of bubbling air/water systems indicated that a pumping action moved particles from adjacent areas at the surface to bubble nucleation sites. To explain the observations, the model considers deposition and …


Optimization Of Flow Direction To Minimize Particulate Fouling Of Heat Exchangers, M.S. Abd-Elhady, C.C.M. Rindt, A.A. Van Steenhoven Jul 2007

Optimization Of Flow Direction To Minimize Particulate Fouling Of Heat Exchangers, M.S. Abd-Elhady, C.C.M. Rindt, A.A. Van Steenhoven

Heat Exchanger Fouling and Cleaning VII

The influence of flow direction with respect to gravity on particulate fouling of heat exchangers is investigated experimentally to determine the optimal flow direction to minimize fouling. Four orientations of flow have been investigated, horizontal flow, upward flow, downward flow and a flow under an angle of 45°. It is observed that fouling starts at the point of stagnation irrespective of the flow direction, and also at the top of the heat exchanger tubes. Particulate fouling grows from these two points till they meet and the fouling layer covers the whole surface of the heat exchanger tube. Fouling at the …


Effect Of Thermal Contact Resistance On The Heat Transfer In Plate Finned Tube Heat Exchangers, D. Taler Jul 2007

Effect Of Thermal Contact Resistance On The Heat Transfer In Plate Finned Tube Heat Exchangers, D. Taler

Heat Exchanger Fouling and Cleaning VII

Plate fin-and-tube heat exchangers are made by inserting oval tubes through sheet metal strips with stamped holes and then expanding the tubes slightly to cause pressure at the tube-to-strip contacts. The gap between the fin base and the outer tube surface may be filled with air or corrosion products causing a decline in the ability of plate fins to transfer heat. The contact resistance must be accounted for in the design and performance calculations of heat exchangers. In this paper, the thermal contact resistance of the fin-to-tube attachment is estimated from the condition that the dimensionless correlations for the Colburn …


Fouling During The Use Of ‘Fresh’ Water As Coolant- The Development Of A ‘User Guide’, S. J. Pugh, G. F. Hewitt, H. Müller-Steinhagen Jul 2007

Fouling During The Use Of ‘Fresh’ Water As Coolant- The Development Of A ‘User Guide’, S. J. Pugh, G. F. Hewitt, H. Müller-Steinhagen

Heat Exchanger Fouling and Cleaning VII

IHS ESDU recently published its latest ‘User Guide’ to fouling in heat exchange systems, for systems with fresh water as the coolant. ESDU 07006 [1] is the third in a group, following the development of the Crude Oil Fouling User Guide [2] issued in 2000 and the Seawater Fouling User Guide [3] issued in 2004. ESDU 07006 was developed by IHS ESDU over a period of five years under the guidance of the Oil Industry Fouling Working Party, a collaborative team of oil refiners, heat transfer equipment and services suppliers and Universities. It provides designers and operators of cooling water …


Achievements And Potential Of Self-Cleaning Heat Exchangers Using Untreated Natural Seawater As A Coolant, D.G. Klaren, E.F. De Boer Jul 2007

Achievements And Potential Of Self-Cleaning Heat Exchangers Using Untreated Natural Seawater As A Coolant, D.G. Klaren, E.F. De Boer

Heat Exchanger Fouling and Cleaning VII

The fluidized bed self-cleaning heat exchange technology has been developed in the 70s for the application in thermal desalination plants, like Multi-Stage Flash (MSF) evaporators. This paper summarizes the achievements of the Multi-Stage Flash / Fluidized Bed Evaporator (MSF/FBE) in the past, but also pays attention to its market potential today, whether or not in combination with the possible revamp of existing conventional MSF plants into a better performing configuration. Further, this paper also pays attention to the application of the self-cleaning heat exchange technology for closedloop coolers or so-called ‘mother-coolers’ for large chemical plants. Last but not least, attention …


Cleaning And Prevention Of Inorganic Deposits In Plate Heat Exchangers Using Pulsating Current, A. Pehkonen, J. Aromaa, O. Forsén, J. Virtanen, I. Galfi Jul 2007

Cleaning And Prevention Of Inorganic Deposits In Plate Heat Exchangers Using Pulsating Current, A. Pehkonen, J. Aromaa, O. Forsén, J. Virtanen, I. Galfi

Heat Exchanger Fouling and Cleaning VII

Fouling of heat exchangers is a major problem in many industrial processes. The higher temperature of the heat exchange surface compared with the liquid containing precipitable compounds causes the formation of inorganic deposits. Removing the deposits on plate heat exchangers is most often carried out by high-pressure cleaning. This is a laborious task and often increases the corrosion rate of the plates by increasing the roughness of the cleaned surface. This study presents an electrochemical method to clean heat exchange surfaces fouled by deposits and to prevent formation of deposits. This method utilizes pulsating current to polarize heat exchange surfaces …


Automatic Tube Cleaning System (Atcs) Installation In Sulfide Retrieval Monoethanolamine Treatment Plant: Case Study And Fouling Global Perspectives, Chemi Sugarmen, Udi Siboni, Ruth Volansky Jul 2007

Automatic Tube Cleaning System (Atcs) Installation In Sulfide Retrieval Monoethanolamine Treatment Plant: Case Study And Fouling Global Perspectives, Chemi Sugarmen, Udi Siboni, Ruth Volansky

Heat Exchanger Fouling and Cleaning VII

Automatic cleaning of heat exchangers and condensers tubes by means of sponge balls is well known since the early fifties, with expanding application from steam power plants to process industry to industrial cooling and air conditioning systems. Main benefits bottom-lined in cost savings are generally considered as: elimination of maintenance down-time and need for chemical and more efficient operation of process and plant. This paper presents the performance and benefits of an Automatic Tube Cleaning System (ATCS) implementations, in a hydrogen sulfide retrieval Monoethanolamine treatment Plant in Paz Ashdod Refinery, one of the two refineries in Israel. Patented by CQM …


Double Perforated Impingement Plate (Dpip) In Shell-And-Tube Heat Exchanger, S. S. Al-Anizi, A. M. Al-Otaibi Jul 2007

Double Perforated Impingement Plate (Dpip) In Shell-And-Tube Heat Exchanger, S. S. Al-Anizi, A. M. Al-Otaibi

Heat Exchanger Fouling and Cleaning VII

This paper presents a solution to a chronic problem causing repeated tube failure at shell-and-tube heat exchangers. The problem is related to fouling process on tubes surface which accumulates downstream the impingement plate at exchanger inlet nozzle within the first tube rows due to low velocity and vortices production. In fouling services, the suspended deposits, fouling, accumulates on tubes surface downstream the impingement plate causing under-deposit corrosion and raising tubes surface temperature due to lack of cooling accelerating fouling process. Under fouling corrosion attacks tubes and causes repeated tube failure costing a lot of money in terms of material, maintenance …


Cleaning High-Speed Marine Separators With An Environmentally-Friendly Cip Agent, Ulf Nylén, Roger Andersson, Peter Forsberg Jul 2007

Cleaning High-Speed Marine Separators With An Environmentally-Friendly Cip Agent, Ulf Nylén, Roger Andersson, Peter Forsberg

Heat Exchanger Fouling and Cleaning VII

The present contribution is devoted to the cleaning of high-speed marine separators employing the environmentally-friendly Cleaning In Place (CIP) agent Alpacon Multi Cip Super. For this particular study an Alfa Laval lube oil separator of type S831 on board the ship MS Isabella was dismantled prior to its first CIP treatment since installation and a few of the sludge-coated insert discs were taken as samples for laboratory experiments. Following assembly, the separator was cleaned according to a standard CIP protocol. Back in the laboratory, experiments mimicking the field CIP conditions verified the excellent cleaning results observed by visual inspection out …


Biofouling Control In Heat Exchangers Using High Voltage Capacitance Based Technology, R. Romo, M. M. Pitts, N. B. Handagama Jul 2007

Biofouling Control In Heat Exchangers Using High Voltage Capacitance Based Technology, R. Romo, M. M. Pitts, N. B. Handagama

Heat Exchanger Fouling and Cleaning VII

Biofouling in industrial heat exchangers and piping systems is common in water from all sources. Problems generated by biofouling such as corrosion, sludge deposition and scale formation have a costly impact on industrial equipment and productivity. This paper describes an electronic approach using High Voltage Capacitance Based technology (HVCB) to control biofouling in industrial heat exchangers, focusing upon biofilm removal and the prevention of biofilm formation. Four different application case studies are presented in this paper in which the HVCB technology was used to control biofouling. The applications include an evaporative cooling wall in a greenhouse in Oracle, Arizona; a …


Solving A Hydtrotreater Feed Filter Fouling Problem, X.A. Wu, K.H. Chung Jul 2007

Solving A Hydtrotreater Feed Filter Fouling Problem, X.A. Wu, K.H. Chung

Heat Exchanger Fouling and Cleaning VII

Feed filters were installed in Syncrude hydrotreater units to protect the catalyst beds from plugging by fine solids in the feed. Severe filter fouling occurred after a process flow sheet change. The root cause of fouling was revealed through a step-by-step scientific investigation. It was first confirmed that the fouling problem was related to a process flow sheet change that introduced a heavy vacuum gas oil (HVGO) stream into the coker combined gas oil (KCGO) stream prior to filtration. Characterization of the foulant and the feed indicated that the fouling reactions are likely oxidative polymerization. Iron naphthenate or naphthenic acid …


Electrochemical Impedance And Digital Image Methods To Detect Initial Deposition Of Microorganisms, H. Men, S. W. Mu, Z. W. Lu, Y. L. Chen, S.R. Yang, Y. P. Jia, S. X. Cao Jul 2007

Electrochemical Impedance And Digital Image Methods To Detect Initial Deposition Of Microorganisms, H. Men, S. W. Mu, Z. W. Lu, Y. L. Chen, S.R. Yang, Y. P. Jia, S. X. Cao

Heat Exchanger Fouling and Cleaning VII

Microorganism in industrial cooling water can cause corrosion and biofouling. Electrochemical impedance method and digital image method (DIM) were used to detect quantitatively iron bacteria and heterotrophic bacteria. Microorganism growth and metabolism can change the impedance of culture medium. The detection time of impedance variation lie in the function relationship with the logarithm of bacteria concentration. 7-million-pixel CCD sensor was used to shoot the shape of microorganism in order to count the number. Compared with most probable number (MPN) method, the detection time of electrochemical impedance is shortened. The DIM reduces the bacteria counting time and the inaccuracy associated with …


Bottomless, Pir Rothenberg Jul 2007

Bottomless, Pir Rothenberg

Harpur Palate: a Literary Journal

pages 64-90


El Disparo De Argón By Juan Villoro: A Symbolic Vision Of Power, Corruption And Lies, Tim Harvard Jul 2007

El Disparo De Argón By Juan Villoro: A Symbolic Vision Of Power, Corruption And Lies, Tim Harvard

Hipertexto

No abstract provided.


Free Alkali-Index For Optimizing The Fuel Mixture In Biomass Co-Firing, T.E. Blomberg Jul 2007

Free Alkali-Index For Optimizing The Fuel Mixture In Biomass Co-Firing, T.E. Blomberg

Heat Exchanger Fouling and Cleaning VII

Co-firing biomass with fossil fuels provides a cheap and efficient reduction of the CO2 emissions in electricity generation. One of the main challenges in co-firing is the increased fouling and corrosion rates of the heat transfer surfaces when biomass is added to the fuel mixture. Optimization of the fuel mixture from the fouling and corrosion point of view would be an easier task, if some fuel properties would provide correlation with the fouling and corrosion rates. Currently there is no clear understanding of the most useful fuel indices. The fouling indices used in coal firing have proved to be less …


The Science Of Cleaning Of Dairy Fouling Layers, R. Mercadé-Prieto,, W.R. Paterson, D.I. Wilson Jul 2007

The Science Of Cleaning Of Dairy Fouling Layers, R. Mercadé-Prieto,, W.R. Paterson, D.I. Wilson

Heat Exchanger Fouling and Cleaning VII

The science underlying the removal of dairy fouling layers, and particularly the dissolution of proteinaceous deposits in alkaline solution, is relatively poorly understood even though this is a critical feature of many cleaning-in-place operations. We report key results from a series of investigations on heat-induced gels of β- lactoglobulin, the primary whey protein component in milk and whey foulant. These model systems were used to elucidate the reaction behaviour of gels and aggregates whereby the proteinaceous material is converted to a softer, swollen form that can then be removed by fluid shear or diffusion. We show that several features, such …


Bacterial And Protein Adhesion On Ni-P-Ptfe Coated Surfaces, Q. Zhao, C. Liu, Y. Liu, S. Wang Jul 2007

Bacterial And Protein Adhesion On Ni-P-Ptfe Coated Surfaces, Q. Zhao, C. Liu, Y. Liu, S. Wang

Heat Exchanger Fouling and Cleaning VII

The adhesion of bacteria and proteins on the surfaces of heat exchangers and food processing equipment has been recognized as a widespread problem. Biofouling not only reduces heat transfer performance significantly, but also causes considerable pressure drop, calling for higher pumping requirements. Biofouling also present a considerable hygiene risk in the food industry. It would be much more desirable if surfaces with an inherently lower stickability for biofouling could be developed. In this paper, stainless steel 304 plates were modified by electroless plating Ni-P and small amounts of PTFE. The experimental results showed that the surface free energy of the …


Metallic Micro Heat Exchangers: Properties, Applications And Long Term Stability, J.J. Brandner, W. Benzinger, U. Schygulla, S. Zimmermann, K. Schubert Jul 2007

Metallic Micro Heat Exchangers: Properties, Applications And Long Term Stability, J.J. Brandner, W. Benzinger, U. Schygulla, S. Zimmermann, K. Schubert

Heat Exchanger Fouling and Cleaning VII

Micro heat exchangers, which until recently have been implemented only at laboratory scale, are now being available for industrial applications. They are well known for their superior heat transfer properties due to the large surface-to-volume ratio. But there are little data available on the long term stability of these devices. In this paper application several application examples for micro heat exchangers made of stainless steel are presented. The devices consist of stainless steel foils providing numerous micro channels generated by mechanical micromachining or wet chemical etching. A number of the foils are arranged in a specific way and bonded together. …


Freakonomics And The Tax Gap: An Applied Perspective, Leslie Book Jul 2007

Freakonomics And The Tax Gap: An Applied Perspective, Leslie Book

Working Paper Series

Over the past thirty years, a significant amount of research from a variety of social science disciplines has considered tax compliance. Economists, psychologists, and sociologists have contributed to the discussion, offering research and, at times, conflicting explanations regarding whether a person is likely to comply with his obligation to file an accurate tax return. The unifying theme among this research is a search for explanatory reasons which are the factors that lead to non-compliance. In broad terms, the economic models of tax compliance assume rational behavior, and that people will coldly consider compliance from the perspective as to whether the …


Fabrication And Application Of Conducting Polymer Micro- And Nano-Patterns, Anirban Chakraborty Jul 2007

Fabrication And Application Of Conducting Polymer Micro- And Nano-Patterns, Anirban Chakraborty

Doctoral Dissertations

Conducting polymers, since their discovery, have attracted significant attention due to their promise of replacing silicon and metals in building devices. They have been shown to have wide applications for biological and chemical sensing as well as for electronic devices. Previous and current efforts have concentrated on building devices of a specific function. When multiple micropatterns of different conducting polymers are fabricated on a common substrate, a versatile microsystem can be envisioned. The existing conducting polymer patterning techniques present some technical challenges of degradation, low throughput, low resolution, depth of field, and residual layer in producing conducting polymer microstructures. To …


Investigation Of The Stability Of The Compressive Residual Stress Generated By Warm Laser Shock Peening, Chang Ye Jul 2007

Investigation Of The Stability Of The Compressive Residual Stress Generated By Warm Laser Shock Peening, Chang Ye

Mechanical Engineering Faculty Research

LaserShock Peening (LSP) has been successfully used to improve component fatigue performance by bringing beneficial compressive residual stress to material surface since the 1990s. However, it has been found that the compressive residual stress generated by room temperature LSP (RT-LSP) is not stable during cyclic loading. Thus, it is necessary to improve the stability of the compressive residual stress generated by RT-LSP. In this study, Warm Laser Shock Peening (WLSP) is proposed as a potential approach to improve the stability of the compressive residual stress. WLSP is to laser peen a component that is being heated to elevated temperatures. As …


"Sociological Legitimacy" In Supreme Court Opinions, Michael Wells Jul 2007

"Sociological Legitimacy" In Supreme Court Opinions, Michael Wells

Scholarly Works

Analysis of a Supreme Court opinion ordinarily begins from the premise that the opinion is a transparent window into the Court's thinking, such that the reasons offered by the Court are, or ought to be, the reasons that account for the holding. Scholars debate the strength of the Court's reasoning, question or defend the Court's candor, and propose alternative ways of justifying the ruling. This Article takes issue with the transparency premise, on both descriptive and normative grounds. Especially in controversial cases, the Court is at least as much concerned with presenting its holding in a way that will win …


Our Legacy Of Neglect: The Longfellow Bridge And The Cost Of Deferred Maintenance, David Westerling, Steve Poftak Jul 2007

Our Legacy Of Neglect: The Longfellow Bridge And The Cost Of Deferred Maintenance, David Westerling, Steve Poftak

Civil Engineering Faculty Publications

The Longfellow Bridge, connecting Boston and Cambridge, is in bad shape, due not only to its age and the ravages of our weather, but also to a troubling and persistent lack of maintenance. Fixing the bridge, in effect paying the bill for our unwillingness to maintain it, is estimated to cost at least $180 million, with the potential for cost overruns reaching into the hundreds of millions. The neglect of the Longfellow Bridge is symptomatic of a problem that encompasses almost all the assets owned by the Commonwealth.