Determination Of Sulfur And Iron Valence By Microprobe, H. Kucha, R. Wouters, O. Arkens Mar 1989

Determination Of Sulfur And Iron Valence By Microprobe, H. Kucha, R. Wouters, O. Arkens

Scanning Microscopy

SKα, SKβ and FeKβ valence related wavelength changes are large enough to be measured with microprobe spectrometers. The relative difference between S2- and S6+ is measured as 1.27 eV for the SKα line and 1.66 eV for the SKβ line. This SKα and SKβ peak shift is function of the valence. Accurate microprobe measurement of the peak shift allows the determination of the sulfur valence in a microarea. The relative difference between Fe2+ and Fe3+ for the FeKβ line is 0.94 eV. Considering the achieved accuracy of measurements, this peak can only be used for an …


'Spot The Difference': Finding Small Differences Between Closely Similar Images, A. A. Mills Mar 1989

'Spot The Difference': Finding Small Differences Between Closely Similar Images, A. A. Mills

Scanning Microscopy

Small differences between two complex and closely-similar photographs may be located by viewing the uniformly illuminated pair with a stereoscope. Provided the observer possesses normal stereoscopic vision, any non-common elements will appear to stand above the general picture plane provided by the fused common background. It is emphasised that the images being examined are not a conventional stereo-pair, although the left- or right-eye member of such a pair may be so compared with its counterpart in a subsequent stereopair. This stereoscopic technique was found preferable to the alternative 'blink' method for most scanning microscope images, although it is advantageous to …


Analyses Of Dental Pulp In Restored Teeth, D. L. Lentz, J. T. Buchanan, D. R. Basinger Feb 1989

Analyses Of Dental Pulp In Restored Teeth, D. L. Lentz, J. T. Buchanan, D. R. Basinger

Scanning Microscopy

Restored teeth were extracted from test animals at four time intervals (1 hour, 1 day, 1 week, and 3 months) following amalgam insertion. Extracted teeth were frozen in liquid nitrogen, cryo-fractured so as to expose the pulps and then freeze-dried. Pulps were analyzed for mercury content by energy dispersive spectrometry (EDS) and atomic absorption spectrophotometry (AAS). Mercury levels appeared below the detection limits of EDS but could be detected by AAS which showed the highest readings seven days after amalgam insertion.


The Vascular System Of Xenotransplanted Tumors -Scanning Electron And Light Microscopic Studies-, M. A. Konerding, F. Steinberg, V. Budach Jan 1989

The Vascular System Of Xenotransplanted Tumors -Scanning Electron And Light Microscopic Studies-, M. A. Konerding, F. Steinberg, V. Budach

Scanning Microscopy

A widely used model for investigating basic tumor characteristics and different treatment modalities preclinically is the immune-deficient, athymic nude mouse. This model offers many morphological parallelisms to the clinical situation.

The aim of this study is to demonstrate the vascularization pattern of xenotransplanted human melanomas and sarcomas using different methods. Xenotransplanted tumors of 62 congenital thymusaplastic nude mice were examined ultrastructurally and topographically after corrosion cast and tissue preparation. Quantitative measurements of tumors injected with India ink were carried out to obtain comparable information on the vascular densities in the tumors.

Quantitative measurements showed that there is no zonal, topographic …


Dentin: A Dynamic Substrate - A Review, David H. Pashley Jan 1989

Dentin: A Dynamic Substrate - A Review, David H. Pashley

Scanning Microscopy

The structure of dentin is unusual in that the number and size of its tubules changes as one moves from the periphery toward the pulp chamber. Near the pulp, the tubules are very close together and the water con tent of this deep dentin is high. Near the enamel, the tubules are far apart, occupying less than 1% of the surface area. When enamel or dentin is cut, the surface becomes covered by an adherent layer of cutting debris called the smear layer. Its composition presumably reflects the composition of the underlying dentin. It is only about 1 μm thick …


Vascular "Sphincter" And Microangioarchitecture In The Central Nervous System: Constriction Of Intraparenchymal Blood Vessels Following A Treatment Of Vasoconstrictive Neurotransmitter, K. Nakai, Y. Naka, H. Yokote, T. Ikatura, H. Imai, N. Komai, T. Maeda Jan 1989

Vascular "Sphincter" And Microangioarchitecture In The Central Nervous System: Constriction Of Intraparenchymal Blood Vessels Following A Treatment Of Vasoconstrictive Neurotransmitter, K. Nakai, Y. Naka, H. Yokote, T. Ikatura, H. Imai, N. Komai, T. Maeda

Scanning Microscopy

The site of action of neuropeptide Y (NPY), a potent vasoconstrictive neurotransmitter, on the intraparenchymal blood vessels in the rat parietal cortex was demonstrated using a corrosion cast technique with scanning electron microscopy. Our observations were confined to the cortical area where the regional cerebral blood flow (rCBF) had been reduced significantly by in situ application of NPY. A striking finding in that area was the diffuse narrowing of the perforating arteries in the upper cortical layers. Ring-like compressions on the corrosion casts, presumably formed by active vascular sphincters along the arteries, capillaries and venules within the brain parenchyma, seemed …


Proposed Rehabilitation And Betterment Program- Draft, United States Department Of The Interior Jan 1989

Proposed Rehabilitation And Betterment Program- Draft, United States Department Of The Interior

Elusive Documents

No abstract provided.


Restorative Dental Materials: Scanning Electron Microscopy And X-Ray Microanalysis, Grayson W. Marshall Jr., Sally J. Marshall, Stephen C. Bayne Oct 1988

Restorative Dental Materials: Scanning Electron Microscopy And X-Ray Microanalysis, Grayson W. Marshall Jr., Sally J. Marshall, Stephen C. Bayne

Scanning Microscopy

Restorative dental materials include the materials used to repair damaged teeth and/or replace missing teeth. The definition could be extended to include a much broader group of dental materials, but this paper concentrates only on those materials used to restore the crown portion of damaged teeth. Auxiliary materials, materials for removable denture prostheses, and root canal materials are excluded. Progress and recent research utilizing SEM (Scanning Electron Microscopy), EDS (Energy Dispersive Spectroscopy), and some related methods are presented for the following dental materials: dental amalgam, enamel and dentin bonding agents, dental composites, dental cements, casting alloys for crowns and bridges, …


Vascularization Of Male Gonads In Blennius Pavo (Teleostei, Blenniidae) As Revealed By Scanning Electron Microscopy Of Vascular Corrosion Casts, F. Lahnsteiner, A. Lametschwandtner, R. A. Patzner, H. Adam Oct 1988

Vascularization Of Male Gonads In Blennius Pavo (Teleostei, Blenniidae) As Revealed By Scanning Electron Microscopy Of Vascular Corrosion Casts, F. Lahnsteiner, A. Lametschwandtner, R. A. Patzner, H. Adam

Scanning Microscopy

The vascular architecture of male gonads of Blennius pavo is studied by scanning electron microscopy of vascular corrosion casts. Arterial supply to the gonads is by a branch of the first ventral segmental artery of the tail. From the surface of the gonads, this vessel gives rise to branches which supply testes, spermatic ducts, testicular glands, blind pouches, urogenital sinus and urogenital papilla. The testis has a rope-ladder-like capillary network around the seminiferous tubules, while in the testicular gland the capillary network is irregular in form. The spermatic ducts are found to have an exterior capillary network located in the …


Uogas - A Get Away Special Satellite With Orbit-Raising Capability, Ralph Lorenz Sep 1988

Uogas - A Get Away Special Satellite With Orbit-Raising Capability, Ralph Lorenz

Small Satellite Conference

The low cost of satellite deployment from Shuttle GAS canister makes it an attractive launch option. However, the low deployment altitude severely constrains lifetime so the UoGAS (University of Surrey Get Away Special) spacecraft will incorporate a propulsion system. Lifetime extension methods are considered and a start-of-mission orbit-raising manoeuvre is selected. An orbit dynamics simulation method (taking into account the atmospheric drag) is discussed and results presented. Mission profiles, propulsion systems (including colloid, resistojet and cold gas thrusters, as well as a novel hybrid bipropellant combination) and stabilisation options are discussed: an aerodynamically stabilised vehicle with a resistojet propulsion system …


Determination Of Fiber Content In Long Fiber Reinforced Composites By Scanning Electron Microscopy And Image Analysis, R. F. Antrim Sep 1988

Determination Of Fiber Content In Long Fiber Reinforced Composites By Scanning Electron Microscopy And Image Analysis, R. F. Antrim

Scanning Microscopy

Currently, there is a wide interest in further developing long fiber reinforced composites. Due to the dependence of a material's mechanical properties to its microstructure, further development of microanalytical techniques is needed to quantify the amount of fiber. In response, a standardless technique was developed to determine the volumetric fiber content and its variation in an oriented long fiber reinforced composite. The method utilizes scanning electron microscopy to acquire backscattered electron images of polished cross-sections. The images are then processed to determine the fiber area fraction which, in this particular case, is equal to the volume fraction. The results presented …


Determination Of Nitrogen In Stainless Steel By Auger Electron Spectroscopy, H. Hantsche, H. J. Dudek Jun 1988

Determination Of Nitrogen In Stainless Steel By Auger Electron Spectroscopy, H. Hantsche, H. J. Dudek

Scanning Microscopy

Application properties of steel can be improved considerably by alloying with nitrogen. The nitrogen may be present both as dissolved nitrogen and as nitride precipitate. It is well-known that the determination of low nitrogen content by means of X-ray microprobe analyses (EMPA) is not easy, consequently it seemed only logical to try to perform these measurements with the method of Auger electron spectroscopy ( AES) which is more sensitive as far as detection of light elements is concerned. After determining the line shape and line position of the nitrogen KLL-peak the detection limit was calculated at 0.02 at .% using …


The Growth Of Calcium And Strontium Sulfates On Barium Sulfate Surfaces, L. Perez, G. H. Nancollas Apr 1988

The Growth Of Calcium And Strontium Sulfates On Barium Sulfate Surfaces, L. Perez, G. H. Nancollas

Scanning Microscopy

The crystallization of calcium sulfate dihydrate (gypsum) and strontium sulfate (celestite) induced by the presence of barium sulfate (barite) surfaces has been studied using a Constant Composition kinetic method. In contrast to calcium sulfate, strontium sulfate appears to grow epitaxially on barium sulfate surfaces. However, barium sulfate induces calcium sulfate dihydrate precipitation from meta stable supersaturated solutions of the salt. Following nucleation, the rate of growth of strontium sulfate was found to be a second order with respect to supersaturation indicating a surface dislocation growth mechanism. The observed epitaxial growth is in agreement with calculations based on crystal lattice mismatch.


Silver As A Removable Conductive Coating For Scanning Electron Microscopy, A. A. Mills Mar 1988

Silver As A Removable Conductive Coating For Scanning Electron Microscopy, A. A. Mills

Scanning Microscopy

A thin film of silver, applied by sputtering or vacuum evaporation, provides an excellent conformal conductive coating for scanning electron microscopy of insulating specimens. When no longer required it is easily removed with Farmer's reducer a dilute aqueous solution of potassium ferricyanide and sodium thiosulphate. No damage was apparent to fine structure in the calcite matrix of ostracode shells, or to other biological tissues. No problems have been encountered with grain in the silver film at magnifications up to 15,000 X, or in the storage of coated specimens in a desiccator for periods exceeding 6 months.


Microscopic Effects Of Predator Digestion On The Surfaces Of Bones And Teeth, John M. Rensberger, Hartmut B. Krentz Feb 1988

Microscopic Effects Of Predator Digestion On The Surfaces Of Bones And Teeth, John M. Rensberger, Hartmut B. Krentz

Scanning Microscopy

Concentrations of small fossil mammals are frequently encountered in Cenozoic deposits, but the causes for such accumulations have seldom been determined. In many cases the tooth, jaw, and limb fragments appear to be well-preserved under light microscopy, and it is difficult to differentiate damage due to predator digestion from breakage and abrasion due to physical agents. In order to find more specific evidence of predator digestion, we used a scanning electron microscope (SEM) to examine the surface microstructure of bones and teeth consumed by Bubo virginianus (great horned owl) and Canis latrans (coyote), which prey upon similar species. Effects …


The Vascularization Of The Peripheral Nerve Of Chicken And Rat, M. A. Konerding, M. Lehmann, M. Blank Feb 1988

The Vascularization Of The Peripheral Nerve Of Chicken And Rat, M. A. Konerding, M. Lehmann, M. Blank

Scanning Microscopy

The vascular system of the sciatic nerve of chicken and rats was examined by means of the microcorrosion casting technique and freeze-broken specimens.

The main epineural vessels form two lateral and interfascicular vascular bundles which anastomose with one another and also with the peri -and endoneural plexuses. On epi- and perineural vessels one can find morphological correlates for regulative means such as sphincters. Even the endoneural vessels depict numerous anastomoses.

The proximity of the vessels as well as the great number of anastomoses suggests a considerable compensatory potential with an adaptable perfusion rate in case of a partial breakdown of …


Signal Mixing Technique For Backscattered Electrons In The Scanning Electron Microscope, A. Buczkowski, J. Hejna, Z. Radzimski Feb 1988

Signal Mixing Technique For Backscattered Electrons In The Scanning Electron Microscope, A. Buczkowski, J. Hejna, Z. Radzimski

Scanning Microscopy

Signal mixing technique using asymetrically placed backscattered electron detectors in a scanning electron microscope is presented in this paper. Two types of detectors have been used: a low-take off angle ring scintillation detector (placed around the specimen) and a wide-angle semiconductor detector (placed above the specimen). It has been shown that the discussed configuration gives good "real" topography in all directions on the specimen surface and also reduces significantly the pseudo-topography effect of flat grain boundaries.


The Surfaces Of Titanate Minerals, Ceramics And Silicate Glasses: Surface Analytical And Electron Microscope Studies, Sverre Myhra, Roger St.C. Smart, Peter S. Turner Jan 1988

The Surfaces Of Titanate Minerals, Ceramics And Silicate Glasses: Surface Analytical And Electron Microscope Studies, Sverre Myhra, Roger St.C. Smart, Peter S. Turner

Scanning Microscopy

The review evaluates evidence of aqueous surface attack on glasses, titanate minerals and synthetic rock material (Synroc C) available from:- leach rates; surface analysis (XPS, SAM, SIMS); IR spectroscopy; and electron microscopy. Direct observations are described showing the formation of:- ion-exchanged, cation deficient layers; altered glass network and crystal line lattice layers and recrystallised, reprecipitated and surface-segregated layers. The titanate minerals react in the order perovskites > hollandite > fluorite structures (zirconolite, zirkelite, pyrochlore, polymigllyte) > rutile. The formation of amorphous Ti-O films, recrystallising to TiO2 (anatase and brookite), is observed on perovskite and hollandite surfaces. The surface reactivity of the titanate …


Surface Analysis Of Tarnished Dental Alloys, H. J. Mueller, J. W. Lenke, M. S. Bapna Jan 1988

Surface Analysis Of Tarnished Dental Alloys, H. J. Mueller, J. W. Lenke, M. S. Bapna

Scanning Microscopy

Six crown and bridge alloys ranging in nobility between 25-63 wt % (18-45 at %) were analyzed by optical microscopy, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and secondary ion mass spectroscopy (SIMS), as well as by L*a*b* colorimetry before and after in vitro tarnishing in artificial saliva with and without additions of 0.00016, 0.016, and 1.6 % Na2S with a rotating wheel apparatus. All alloys except the lowest of 18 at % changed colors to about the same degree after 72 h of tarnishing. All alloys decreased in L*, while increased in both a* and b*, …


Application Of Scanning Electron Microscopy And X-Ray Microanalysis To Investigate Corrosion Problems In Plain Tinplate Food Cans And Examine Glass And Glass-Like Particles Found In Canned Food, James E. Charbonneau Jan 1988

Application Of Scanning Electron Microscopy And X-Ray Microanalysis To Investigate Corrosion Problems In Plain Tinplate Food Cans And Examine Glass And Glass-Like Particles Found In Canned Food, James E. Charbonneau

Food Structure

Scanning Electron Microscopy (SEM) and X-ray Microanalysis (EDS) have been used to investigate product container interaction problems in plain tinplate metal food containers and to examine glass and glass-like particles that were found in canned food.

Through the use of SEM-EDS, it was determined that: sulfate containing particles from the cannery cooling water reacted with exposed iron or tin-iron alloy on the tinplate surface causing an external rusting problem; sulfur dioxide was responsible for a container discoloration and a pitting corrosion problem in canned fruit nectar; hydrogen sulfide produced from the SO2-tinplate reaction was the cause of an associated off-odor …


Great Salt Lake Interisland Diking: Water Quality Considerations, John I. Blandamer, William J. Doucette, Ryan R. Dupont, Anthony W. Grover, James Herrick, Jean M. Ihnat, Joan E. Mclean, Michael W. Nath, Samuel R. Rushforth, Judith L. Sims, Ronald C. Sims, Wayne A. Wurtsbaugh Jan 1988

Great Salt Lake Interisland Diking: Water Quality Considerations, John I. Blandamer, William J. Doucette, Ryan R. Dupont, Anthony W. Grover, James Herrick, Jean M. Ihnat, Joan E. Mclean, Michael W. Nath, Samuel R. Rushforth, Judith L. Sims, Ronald C. Sims, Wayne A. Wurtsbaugh

Reports

No abstract provided.


The Role Of Scanning Electron Microscopy In Periodontal Research, A. Carrassi, S. Abati, G. Santarelli Dec 1987

The Role Of Scanning Electron Microscopy In Periodontal Research, A. Carrassi, S. Abati, G. Santarelli

Scanning Microscopy

During recent years a great amount of research has led to a better understanding of the etiology, pathogenesis and pattern of progression of periodontal diseases. Scanning electron microscopy (SEM) has contributed to this improvement, mainly with respect to histology of periodontal tissues, the description of the morphology and distribution of bacteria on the exposed root surface, analysis of the host-parasite interactions on the gingival pocket wall, and morphological evaluation of root treatment. This review deals with all these topics. Unusual types of SEM research are also described and discussed. Uncommon sample preparation techniques for SEM in periodontal research are described. …


Microvascular Casting Of The Lung: Vascular Lavage, Dean E. Schraufnagel, Aloisia Schmid Dec 1987

Microvascular Casting Of The Lung: Vascular Lavage, Dean E. Schraufnagel, Aloisia Schmid

Scanning Microscopy

Corrosion casting is an important tool for the study of microvascular structure, but unlike tissue preparation for light and electron microscopy, few controlled studies of the methods for preparation of microvascular casts for scanning electron microscopy have been reported. Most vascular casting begins with rinsing cells from the lumen of the blood vessels, but the necessity of this has not been shown. Because of a report of successful casting without rinsing and light microscopic evidence of edema with complete rinsing prior to casting, this preparation procedure was examined. Casts of lung vasculature that were thoroughly rinsed were compared to those …


Industrial Applications Of Auger Surface Analysis, R. E. Chase, G. S. Cole Dec 1987

Industrial Applications Of Auger Surface Analysis, R. E. Chase, G. S. Cole

Scanning Microscopy

Scanning Auger microscopy is distinguished by its unique combination of surface selectivity, high spatial resolution, ease of identifying elements and quantifying composition, and ability to distinguish between chemical states. This paper describes several applications of scanning Auger microscopy, emphasizing the range of industrial research activities:

1. Electronic Materials. Contamination in an integrated circuit processing facility was identified and procedures for its removal determined. Causes for the delamination of printed circuit board foils were identified. Superlattice films were characterized and the deposition process evaluated.

2. Tribology. Analysis of surfaces in lubricated sliding contact revealed the effects of con tact kinematics and …


Microanalytical And Micromorphological Investigations Of High Temperature Materials With And Without Protective Coatings, Volker Thien, W. Voss Dec 1987

Microanalytical And Micromorphological Investigations Of High Temperature Materials With And Without Protective Coatings, Volker Thien, W. Voss

Scanning Microscopy

The phenomenon "High Temperature Corrosion" (HTC) is described; three different types (pure oxidation, high temperature hot corrosion, low temperature hot corrosion) are defined. HTC is demonstrated taking gas turbine blades as an example. The results of laboratory HTC tests under defined conditions were compared with those of long time engine experience; the agreement is very satisfactory.

Metallurgical investigations with scanning electron microscopy and EDX-/WDX-analytical techniques gave explanations for the behaviour of protective coatings . The corrosion mechanism of a NiCrAlY-plasma spray coating is explained as consequence of Cr- and Al-oxidation. A special analytical technique - the "integral layer profile analysis" …


Microcorrosion Casting In Normal And Pathological Biliary Tree Morphology, E. Gaudio, L. Pannarale, F. Carpino, G. Marinozzi Nov 1987

Microcorrosion Casting In Normal And Pathological Biliary Tree Morphology, E. Gaudio, L. Pannarale, F. Carpino, G. Marinozzi

Scanning Microscopy

The organization of the intrahepatic biliary tree was studied in three dimensions by scanning electron microscopic (SEM) corrosion casts, in normal and cholestatic rat liver.

In the normal liver the observation revealed the features of the biliary passages from the bile canaliculi to the canaliculo-ductular junction, to the ductules and the bile ducts, confirming previous SEM observations.

In cholestatic liver, the modifications and the proliferation of bile ductules appear clearly.

Resin flow from canalicular to sinusoidal network was never observed.

The method was found to be very useful in the evaluation of the architecture of the intrahepatic biliary tree, under …


"Bare Bones" Propulsion For Small, Low Cost Satellites, Richard Daniels Oct 1987

"Bare Bones" Propulsion For Small, Low Cost Satellites, Richard Daniels

Small Satellite Conference

The radio amateur satellite community pioneered in the design, fabrication and launch of small, low-cost satellites. While these satellites became increasingly more sophisticated, they continued for years as piggyback passengers with no capability for orbital adjustment once released. Beginning with the Phase III spacecraft series an onboard propulsion capability was included permitting significant adjustments to the initial orbit. This paper describes the design of the propulsion modules of three Phase III spacecraft initially using a solid rocket motor and moving to a bi-propellant liquid propulsion system in following spacecraft. While the specific hardware and system design utilized may not be …


Proton-Induced X-Ray Emission Spectrometry In Archaeology, C. P. Swann, S. J. Fleming Sep 1987

Proton-Induced X-Ray Emission Spectrometry In Archaeology, C. P. Swann, S. J. Fleming

Scanning Microscopy

Proton-induced x-ray emission (PIXE) spectrometry is fast developing a reputation as a powerful analytical tool in the study of a range of ancient materials, including bronze, iron, gold, glass, faience, and smelting slag. PIXE data allows determination of the primary constituents which would indicate their recipe of production and determine their bulk physical properties (e.g., color of a glass, brittleness in a metal), and of a wide range of trace elements which may indicate the source of raw material s from which an artifact was constituted. Over the past seven years, PIXE spectrometry's primary advantage over other recognized methods now …


X-Ray Microanalysis Of Dentin: A Review, E. Hals, A. B. Tveit, B. Tøtdal Sep 1987

X-Ray Microanalysis Of Dentin: A Review, E. Hals, A. B. Tveit, B. Tøtdal

Scanning Microscopy

The aim of this review was to present a condensed summary of the literature on X-ray microanalysis of dentin, including both energy-dispersive (EDS) and wavelength-dispersive (WDS) analysis. Estimations of concentrations by XMA of dentin should be regarded as semiquantitative values. The Ca level in rat odontoblasts was elevated in the secreting end of the cell body. In predentin Ca accumulated at a concentration of 2% that of mineralized dentin. In coronal dentin the peritubular areas were hypermineralized (Ca, P, Mg). Primary caries lesions showed a decrease of Ca, P, Mg and Cl, and usually an increase of S and Zn. …


Cleaning Procedures For Small Dental Instruments Prior To Sterilization, K. S. Lester, P. Mitchell Sep 1987

Cleaning Procedures For Small Dental Instruments Prior To Sterilization, K. S. Lester, P. Mitchell

Scanning Microscopy

Observations were made in an institutional setting on the quality of cleaning of dental burs. Assessments were made by scanning electron microscopy of surface contamination and change to the surface quality of burs before and after use, and as a result of different cleaning procedures.

The most significant finding was the corrosive action on carbon steel burs of a phosphoric acid based cleaning solution in routine use at the time. We show by comparison the effectiveness and non-corrosive nature of an alternative detergent based on sulfamic acid, and propose a suitable cleaning routine.