Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

University of Arkansas, Fayetteville

Discipline
Keyword
Publication Year
Publication
Publication Type

Articles 361 - 375 of 375

Full-Text Articles in Entire DC Network

Molten Salt Electrolytes For Electrodeposition Of Cdte Films, Arif Raza, Robert Engelken, Brandon Kemp, Arees Siddiqui, Omer Mustafa Jan 1995

Molten Salt Electrolytes For Electrodeposition Of Cdte Films, Arif Raza, Robert Engelken, Brandon Kemp, Arees Siddiqui, Omer Mustafa

Journal of the Arkansas Academy of Science

We report preliminary investigation of several molten salt electrolytes containing CdCl2 and TeCl4 for the electrodeposition of CdTe films at temperatures well above (>250 °C) those used with aqueous and organic electrolytes. These high temperatures have potential todramatically increase the crystallite size (Poole, Engelken, et al., 1994), as is important for optoelectronic device applications of CdTe, a leading II-VIsemiconductor. This paper willsurvey the results obtained withelectrolytes such as B2O,/HBO2 (m.p. - 230'C), NaCH3COO (m.p. » 324°C), ZnCl2 (m.p. - 283*C), and LiCl/KCl (m.p. * 350 °C), with an emphasis on the latter two. Key material to be presented includes …


Multisite Microprobes For Electrochemical Recordings In Biological Dynamics, G. Sreenivas, S. S. Ang, R. M. Ranade, A. S. Salian, W. D. Brown Jan 1994

Multisite Microprobes For Electrochemical Recordings In Biological Dynamics, G. Sreenivas, S. S. Ang, R. M. Ranade, A. S. Salian, W. D. Brown

Journal of the Arkansas Academy of Science

For over 30 years, techniques have been developed that allow for the microscale (10-30 /mum) measurement of chemical signals with high temporal resolution (1-200 Hz). Such measurements, called in vivo electrochemical recordings, allow for the direct determination of neurotransmitter molecules and related compounds in biological systems. Multiple recordings, simultaneously performed at different, closely spaced, well defined locations throughout a three-dimensional tissue volume in the brain, are of interest in neuroscience. Developments in microelectronic techniques enable the fabrication of multi-electrode microprobes for recording extracellular action potentials generated by individual neurons simultaneously. A high-yield microfabrication process has been successfully developed for the …


Determination Of The Suitability Of Arkansas River Water For Municipal, Industrial And Agricultural Use: Volume 4 Cost Analyses, Joseph Watt, James W. Moore May 1990

Determination Of The Suitability Of Arkansas River Water For Municipal, Industrial And Agricultural Use: Volume 4 Cost Analyses, Joseph Watt, James W. Moore

Arkansas Water Resources Center Technical Reports

Volume IV of the overall report for the project to determine the suitability of the Arkansas River for municipal, agricultural and industrial water supplies contains the cost information calculated using WATER MAID. WATER MAID is an interactive software program for use in calculating treatment plant costs. The software program was developed for the Environmental Protection Agency. The research project was conducted under contract with the Arkansas Soil and Water Conservation Commission.


Determination Of The Suitability Of Arkansas River Water For Municipal, Industrial And Agricultural Use, James W. Moore Jan 1989

Determination Of The Suitability Of Arkansas River Water For Municipal, Industrial And Agricultural Use, James W. Moore

Arkansas Water Resources Center Technical Reports

River water samples from the five sites were collected by the U. S. Geological Survey (USGS) in accordance with their established sampling procedures. Samples for wet chemistry and atomic absorption analyses were delivered to the Bell Engineering Center at the University of Arkansas by USGS personnel. Samples for organics analyses from the Lee Creek, Dardanelle, Little Rock and Pine Bluff sites were delivered by USGS to American Interplex in Little Rock. Samples for organics analyses for the Van Buren site were delivered to the Bell Engineering Center and sent by United Parcel Service (next day air) to Daily Analytical Services …


Integrated Circuits Interconnect Metallization For The Submicron Age, Kamesh V. Gadepally, Roger M. Hawk Jan 1989

Integrated Circuits Interconnect Metallization For The Submicron Age, Kamesh V. Gadepally, Roger M. Hawk

Journal of the Arkansas Academy of Science

The interconnect metallization being used by the semiconductor industry has been aluminum or aluminum silicon. Aluminum silicon is being replaced by aluminum copper and aluminum copper silicon, due to its superior resistance to electromigration and hillock growth. This paper discusses the implementation of aluminum copper/silicon alloys in semiconductor processing, along with a review of the problems and advantages of the same.


Evaluation Of Packed Towers For Removing Volatile Organics From Surface Waters, James W. Moore Jun 1986

Evaluation Of Packed Towers For Removing Volatile Organics From Surface Waters, James W. Moore

Arkansas Water Resources Center Technical Reports

This study analyzes the potential of packed tower aeration as a remedial treatment process for the removal of trace organics on either an acute or chronic basis. Both pilot-scale installations of the packed tower process were reviewed. Included are basic modeling considerations for the removal of volatile trace organics from raw water. Included also is an assessment of the state of the technology as applied to air stripping of water.


Causes Of Localized Copper Corrosion In Drinking Water Supplies, R. A. Sims, R. W. Raible May 1983

Causes Of Localized Copper Corrosion In Drinking Water Supplies, R. A. Sims, R. W. Raible

Arkansas Water Resources Center Technical Reports

Excessive amounts of copper have been observed in drinking water at certain installations on Lake DeGray and at isolated locations in the Arkadelphia area of Arkansas. A study of these installations was conducted to determine the source of the copper contamination. The supply water was very low in copper and therefore dissolution of the copper plumbing caused by low water pH and long residence times was determined to be the most probable source.


Chemistry Of The Spring Waters Of The Ouachita Mountains Excluding Hot Springs, Arkansas, George H. Wagner, Kenneth F. Steele Mar 1980

Chemistry Of The Spring Waters Of The Ouachita Mountains Excluding Hot Springs, Arkansas, George H. Wagner, Kenneth F. Steele

Arkansas Water Resources Center Technical Reports

This report is based on the chemical analysis of the waters from 93 springs and 9 wells. Springs, when free from metal plumbing, provide an uncontaminated source of the ground water and it was desired to obtain water uncontaminated with metals. A few wells were added to the list, usually because of their unique location in the sampling grid.


Trace Element Composition Of Stream Sediments An Integrating Factor For Water Quality, Kenneth F. Steele, Harold C. Macdonald, George H. Wagner, William S. Bowen Jun 1975

Trace Element Composition Of Stream Sediments An Integrating Factor For Water Quality, Kenneth F. Steele, Harold C. Macdonald, George H. Wagner, William S. Bowen

Arkansas Water Resources Center Technical Reports

Bottom sediments, suspended sediments, and water were sampled along 130 miles of the Buffalo River in northern Arkansas. The water and acid extracts of the suspended sediments and the minus 95 mesh fraction of the bottom sediments were analyzed by atomic absorption spectrometry. All samples were analyzed for Na, K, Mg, Ca, Zn, Cd, Cu, Pb, Fe, Co, Cr, Ni, and Mn. Selected bottom samples also were analyzed by As, Hg, and Zr. Zr was determined by x-ray fluorescence. Li and Sr were determined for selected water and suspended sediment samples. There is a general decrease downstream in Fe, Cu, …


Apparatus For Dielectric Constant Measurements And Measurements For Water-Methanol Mixtures, James O. Wear Jan 1970

Apparatus For Dielectric Constant Measurements And Measurements For Water-Methanol Mixtures, James O. Wear

Journal of the Arkansas Academy of Science

A system for measuring dielectric constants has been constructed using a Sargent Oscillometer and an air bath for temperature control. The design and construction of the air bath as well as the temperature control achieved with it are described. The overall performance of the system including a computer program for forming the calculations is described. The system is one that requires calibration using two or more standard solvents and is good for both conducting and non-conducting liquids. Data are presented for water-methanol mixtures at 25 degrees with several points near pure methanol and also near pure water


Groundwater Aquifer Patterns And Valley Alluviation Along Mountain Fork Creek, Crawford County, Arkansas, H. F. Garner Jan 1966

Groundwater Aquifer Patterns And Valley Alluviation Along Mountain Fork Creek, Crawford County, Arkansas, H. F. Garner

Journal of the Arkansas Academy of Science

No abstract provided.


31st Annual Meeting 1947. Program, Academy Editors Jan 1950

31st Annual Meeting 1947. Program, Academy Editors

Journal of the Arkansas Academy of Science

No abstract provided.


Proceedings Of The Arkansas Academy Of Science - Volume 3 1950, Academy Editors Jan 1950

Proceedings Of The Arkansas Academy Of Science - Volume 3 1950, Academy Editors

Journal of the Arkansas Academy of Science

No abstract provided.


32nd Annual Meeting 1948. Program And Abstracts, Academy Editors Jan 1950

32nd Annual Meeting 1948. Program And Abstracts, Academy Editors

Journal of the Arkansas Academy of Science

No abstract provided.


Some Useful Devices For The Chemical Laboratory, L. B. Roberts Jan 1941

Some Useful Devices For The Chemical Laboratory, L. B. Roberts

Journal of the Arkansas Academy of Science

No abstract provided.