Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Engineering (7985)
- Arts and Humanities (3236)
- Physical Sciences and Mathematics (2725)
- Life Sciences (2151)
- Social and Behavioral Sciences (1939)
-
- Civil and Environmental Engineering (1731)
- Mechanical Engineering (1643)
- Electrical and Computer Engineering (1610)
- Architecture (1431)
- Art and Design (1241)
- Construction Engineering and Management (1029)
- Philosophy (942)
- Physics (922)
- Business (794)
- Computer Sciences (788)
- Aerospace Engineering (756)
- Computer Engineering (722)
- Education (721)
- Biology (714)
- Urban, Community and Regional Planning (689)
- Biomedical Engineering and Bioengineering (643)
- Creative Writing (641)
- Communication (622)
- Operations Research, Systems Engineering and Industrial Engineering (590)
- Materials Science and Engineering (586)
- Manufacturing (545)
- Photography (517)
- Electrical and Electronics (501)
- Film and Media Studies (475)
- Architectural Engineering (448)
- Keyword
-
- Curriculum (194)
- Design (190)
- Sustainability (186)
- Construction (185)
- Irrigation (175)
-
- Education (136)
- Faculty Affairs (132)
- Marketing (115)
- Agricultural Education (114)
- Solar (104)
- Performance Based Design (101)
- Cal Poly (93)
- Communication (92)
- Academic Senate (89)
- Agriculture (89)
- Concrete (83)
- Machine Learning (80)
- Fire Dynamics Simulator (FDS) (79)
- RSET (77)
- California (76)
- ASET (75)
- Simulation (75)
- FFA (72)
- Materials Engineering (67)
- Power (67)
- Life Safety Code (65)
- Safety (65)
- Construction Management (64)
- CubeSat (63)
- Efficiency (63)
- Publication Year
- Publication
-
- Cal Poly Student Newspaper (7259)
- Press Releases (4578)
- Master's Theses (3331)
- Cal Poly Report (2224)
- Academic Senate Minutes (1488)
-
- Academic Senate Agendas (1374)
- Electrical Engineering (1062)
- Construction Management (1029)
- Mechanical Engineering (1027)
- Academic Senate Resolutions (1020)
- Physics (899)
- Between the Species (897)
- Cal Poly Magazine (823)
- .RAW Journal of Art and Design (792)
- Fresh Voices: Composition at Cal Poly (714)
- Biological Sciences (576)
- STAR Program Research Presentations (563)
- Computer Science and Software Engineering (457)
- Architectural Engineering (449)
- City and Regional Planning (423)
- Materials Engineering (418)
- Focus (404)
- BioResource and Agricultural Engineering (401)
- Graphic Communication (393)
- Industrial and Manufacturing Engineering (365)
- Computer Engineering (355)
- Civil and Environmental Engineering (345)
- Biomedical Engineering (324)
- Feminist Pedagogy (319)
- Agricultural Education: Graduate Internship Reports (305)
- Publication Type
- File Type
Articles 10021 - 10050 of 42558
Full-Text Articles in Entire DC Network
Office Building- Fire Protection Systems Evaluation, Christine Newton
Office Building- Fire Protection Systems Evaluation, Christine Newton
Fire Protection Engineering: Culminating Experience Project Reports
This report is a Life Safety Code (LSC) and fire protection systems evaluation of an office building located in Colorado. This report covers the prescriptive analysis of the building, as well as the performance‐based aspect of the evaluation.
The prescriptive analysis of this report includes assessment of the building code for structural design, means of egress, detection and notification systems, smoke control system, and the water‐ based fire suppression system for this building. The 2012 International Building Code (IBC) and the National Fire Protection Agency (NFPA) 101 LSC were used for the prescriptive based evaluation and the building was determined …
Centennial Station- Evaluation, Brandon Huffman
Centennial Station- Evaluation, Brandon Huffman
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this analysis is for completion of FPE 596 Culminating Experience in Fire Protection Engineering course in the Fire Protection Engineering Program at California Polytechnic State University. This analysis has been compiled using previous design courses evaluating the egress analysis, suppression design, alarm and detection design, smoke control system design, and structural fire protection. The context of the courses studied both prescriptive and performance based design approaches.
The building chosen for the analysis is Centennial Station located approximately 15 miles south of Denver, Colorado at 12154 East Easter Avenue, Englewood, CO 80112. The facility was designed specifically for …
Mayo Clinic Specialties Building- Fire And Life Safety Report, Taylor Bateman
Mayo Clinic Specialties Building- Fire And Life Safety Report, Taylor Bateman
Fire Protection Engineering: Culminating Experience Project Reports
The MCS Building is a medical clinic facility located in Phoenix, Arizona. It is a four-story building with roughly 40,000 square feet of occupied floor area per story. The MCS Building is connected to an adjoining hospital on all four occupied stories, and is not considered a separate building from the hospital in accordance with the 2012 International Building Code (IBC). However, for the academic purposes of this report, only the fire and life safety features of the MCS Building are discussed, as if it is a separate building. It consists primarily of medical offices and outpatient clinics, and is …
University Of Southern California Heritage Hall- Fire Protection And Life Safety Analysis, Ivan Popilyanu
University Of Southern California Heritage Hall- Fire Protection And Life Safety Analysis, Ivan Popilyanu
Fire Protection Engineering: Culminating Experience Project Reports
This fire protection and life safety analysis is submitted in partial fulfillment of the requirements for the Master of Science Degree from California Polytechnic State University, San Luis Obispo. The study was performed on the University of Southern California’s Heritage Hall, which includes both a code-determined prescriptive examination and a performance-based analysis. The purpose of this review is to evaluate the Heritage Hall address based on compliance with all applicable codes and standards, as well as the determined occupant tenability criteria. The prescriptive examination of Heritage Hall consisted of the evaluation of all structural fire protection, egress analysis and design, …
Regional Office Building- Fire And Life Safety Analysis, Peter Dwan
Regional Office Building- Fire And Life Safety Analysis, Peter Dwan
Fire Protection Engineering: Culminating Experience Project Reports
This report has two objectives: 1. To confirm that the Fire and Life Safety Systems of a project building satisfy applicable prescriptive code requirements, and 2. To evaluate how the Fire and Life Safety Systems perform when challenged by a credible fire scenario.
The three‐story, 31,430 sq. ft. project building is the regional office for an oil and gas company operating in Western Canada. The building includes an atrium which extends from the ground level, main floor to the third floor.
The Fire and Life Safety Systems within the scope of this study, include:
Fire Detection and Alarms Systems (FDAS) …
Sheraton Hotel- Life Safety Report, Raul M. Farfan
Sheraton Hotel- Life Safety Report, Raul M. Farfan
Fire Protection Engineering: Culminating Experience Project Reports
This report evaluates the prescriptive life safety requirements for levels one (1) through four (4) of the Sheraton Hotel in downtown Phoenix. In addition, this report discusses two fire scenarios that evaluate the tenability during egress the in pre-function area on level two (2) and in the main ballroom on level three (3) of the hotel.
The prescriptive standards/codes used to evaluate the hotel are the International Building Code (IBC), International Fire Code (IFC), and applicable standards from the National Fire Protection Association (NFPA). Performance based analysis were conducted using Pathfinder, CFast, and Fire Dynamic Simulator (FDS). Two fire scenarios …
Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett
Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett
Fire Protection Engineering: Culminating Experience Project Reports
The fire protection and life safety systems for Building X were evaluated for compliance in accordance with applicable nuclear power plant non-power block regulatory requirements, NEIL, INPO, IBC, and NFPA design requirements, codes, and standards. Building X is a one-story building with two internal balconies with 10 occupants per balcony, which is made of non-combustible materials that also has a partial basement with concrete walls (is normally unoccupied), which houses potable water pumps and piping for the facility. Building X falls under the definition of mixed occupancy per the International Building Code (IBC) and the Life Safety Code (LSC). Since …
Orange Grove Library- Prescriptive And Performance-Based Fire And Life Safety Evaluation, David A. Boackle
Orange Grove Library- Prescriptive And Performance-Based Fire And Life Safety Evaluation, David A. Boackle
Fire Protection Engineering: Culminating Experience Project Reports
This report describes the analysis of the Orange Grove Library in Gulfport, Mississippi, using prescriptive and performance-based techniques to evaluate fire and life safety. The prescriptive analysis is broken down into four components: alarm, egress, structural and suppression. Prescriptive codes are written by consensus, such that adhering to these codes will produce a reasonable balance between cost, function and safety. The performance-based design analysis uses analytical tools to predict how this particular building would perform under specific fire conditions, chosen based on the actual building in place. Life safety is the primary goal of this analysis. Achievement of this goal …
Analysis Of Costco, San Francisco, Ian Levine
Analysis Of Costco, San Francisco, Ian Levine
Fire Protection Engineering: Culminating Experience Project Reports
This report provides an in-depth analysis of the fire safety systems and design considerations of the Costco store located at 450 10th Street in San Francisco, California, satisfying the requirements for completion of the FPE 596 – Culminating Experience in Fire Protection Engineering academic series. The building is introduced, followed by an analysis of the building structure, alarm and detection, egress, and sprinkler systems are designed based on prescriptive code. These systems are then analyzed from a performance based perspective to gain understanding of how the systems will respond to a challenging design fire. Their response is used to determine …
Henderson Engineers Building- Fire Protection, Life Safety Code Compliance, And Key Issues Report, Alex Ataiyan
Henderson Engineers Building- Fire Protection, Life Safety Code Compliance, And Key Issues Report, Alex Ataiyan
Fire Protection Engineering: Culminating Experience Project Reports
A fire protection and life safety analysis of the Henderson Engineers, Inc. (HEI) building in Lenexa, KS (Kansas City) is performed. Both prescriptive and performance-based methods have been used to evaluate the building against the codes and standards of the 2012 International Building Code (IBC).
The following prescriptive fire protection and life safety systems were analyzed: Occupancy Classification, Building Construction Type, Fire Protection Features, Structural Fire Protection, Fire Barriers, Automatic Fire Sprinkler System, Fire Alarm System, and Means of Egress
During the prescriptive approach, the following deficiencies were identified: 1) As-builts indicate a horizontal assembly fire-resistance rating of only 1-hour, …
Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman
Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman
Fire Protection Engineering: Culminating Experience Project Reports
A Fire Protection & Life Safety Analysis was conducted in order to fulfill the requirements for the degree of Master of Science in Fire Protection Engineering. The Fire Protection & Life Safety Analysis consisted of a prescriptive and performance-based analysis of the Eric Rood Administration Center (Rood Center).
The prescriptive based analysis was conducted to determine if the Rood Center adhered to the applicable codes and standards. It utilized the 2013 California Building and Fire Codes and the 2012 Life Safety Code (NFPA 101). Other NFPA codes that were referenced included the 2013 edition of NFPA 13, Standard for the …
Welding Procedure Qualification Of A36 Steel Plates Using The Gtaw And Gmaw Processes, Brecken Deoilers, Neri Lupian, Regan Rumph
Welding Procedure Qualification Of A36 Steel Plates Using The Gtaw And Gmaw Processes, Brecken Deoilers, Neri Lupian, Regan Rumph
Materials Engineering
The purpose of this project was to qualify welding procedure specifications for the Las Positas College welding program using A36 steel in accordance with American Welding Society (AWS) D1.1, B4.0, and B2.1. Qualification was to be performed using both 1G (flat) and 3G (vertical) positions for Gas Tungsten Arc Welding (GTAW) and Gas Metal Arc Welding (GMAW) processes. Required qualification procedures included two face and two root bend tests coupled with a visual inspection for cracks within the weld region greater than ⅛” long, along with two reduced section tensile tests to ensure the tensile strength exceeded 58 ksi if …
Effect Of Thermal Exposure On Tensile Strength And Microhardness Of Welded And Precipitation Hardened Rx82 Aluminum Alloy Extrusions In The T4 And T6 Conditions, Lucien Miller
Materials Engineering
This investigation is focused on the effect paint-bake cycles have on the tensile strength and microhardness of GMAW welded RX82 aluminum extrusions in T4 and T6 base conditions. To simulate the paint-bake cycle, T4 and T6 RX82 aluminum samples were GMAW welded and heat treated at 350°F, 390°F, and 425°F for durations of 30 minutes, 1.0 hour, and 2.0 hours, with five replicates for each treatment. Microhardness profiles of T4 samples treated at 350°F for 30 minutes and 1.0 hour display weld/HAZ HV values of 86.04 and 82.51 respectively, followed by maximums of 123.21 and 121.10. Average ultimate tensile strength …
Predicting Flexural Strength Of Composite Honeycomb Core Sandwich Panels Using Mechanical Models Of Face Sheet Compressive Strength, Nicholas Bruffey, William Shiu
Predicting Flexural Strength Of Composite Honeycomb Core Sandwich Panels Using Mechanical Models Of Face Sheet Compressive Strength, Nicholas Bruffey, William Shiu
Materials Engineering
The design process at Zodiac Aerospace requires the ability to accurately predict the strength of a composite honeycomb core sandwich panel to adhere to strict FAA regulations. The most common failure mode in long beam composites is in compression. Following ASTM D7249 for a four-point bend test of a long beam flexural test, a mechanical model has been developed that relates the compressive strength of glass fiber face sheets to the flexural strength of the sandwich panel. Zodiac does not currently have data on the compressive strength of the face sheets, so testing was performed to find this property. Asymmetric …
Shear Strength Of Carbon Fiber/Epoxy Hinges Using The V-Notch Rail Shear Test, Calvin Noetzel
Shear Strength Of Carbon Fiber/Epoxy Hinges Using The V-Notch Rail Shear Test, Calvin Noetzel
Materials Engineering
The mechanical properties of carbon fiber reinforced polymer (CFRP) hinges produced by Common Fibers (Kent, Washington) are a new technology with uncharacterized mechanical properties. Currently, Common Fiber’s hinges are utilized in wallets, but in order to expand the application of the hinges to structural components, complete characterization of the mechanical properties of the hinges is necessary. To address this problem, hinges developed by Common Fibers were tested utilizing the V-Notch rail shear test, ASTM D7078, to determine the shear strength of the hinges. Two layups, [+45/-45/0]s and [0/+45/-45/0]s were produced by Common Fibers for the experiment. Hinged and …
Mechanical Properties Of Solid-State Resistance Welded Nitinol - 304 Stainless Steel Joints In Peripheral Guide Wires, Jennifer Rowe
Mechanical Properties Of Solid-State Resistance Welded Nitinol - 304 Stainless Steel Joints In Peripheral Guide Wires, Jennifer Rowe
Materials Engineering
Abbott Vascular manufactures medical guide wires that consist of 304 stainless steel wire joined to superelastic nickel titanium (Nitinol) wire by a solid-state resistance butt welding process. The objective of this project was to develop a deeper understanding of the mechanical properties of the welds in the guide wires. The wires tested were manufactured using two different processes and then ground to various diameters in the weld region. Vickers microhardness measurements were collected in the longitudinal direction across the heat-affected zones of the welds, as well as the transverse direction across the diameters of the welds. Micrographs of the welds …
Buckling Strength In Carbon Fiber Polymer Matrix Composites Produced By Filament Winding For Structural Use In Rockets, Kyle Rosenow
Buckling Strength In Carbon Fiber Polymer Matrix Composites Produced By Filament Winding For Structural Use In Rockets, Kyle Rosenow
Materials Engineering
High-powered rockets use thin walled carbon-fiber reinforced polymer (CFRP) tubes as the primary structure and the tubes experience compressive stress during flight, which is estimated at 18MPa. Cal Poly Space Systems (CPSS) recently acquired the capability to use filament winding for manufacturing CFRP structures. Filament winding wraps carbon-fiber tow coated in epoxy around an axisymmetric object, and in this case, an aluminum cylinder. The tube laminate is an angle-ply orientation testing the winding angles 35°, 50°, 65°, and 80° and winding patterns 1/1 and 8/1 in combination using an unsupported parallel compression test. Coupons are one-inch in height, 2.5 inches …
Effect Of Metal Organic Framework Concentration On The Crystallization Of Pla-Al-Mof Composites, Eric Futak, Jeffrey Norton, Jessie O'Connell, Nestor Vazquez
Effect Of Metal Organic Framework Concentration On The Crystallization Of Pla-Al-Mof Composites, Eric Futak, Jeffrey Norton, Jessie O'Connell, Nestor Vazquez
Materials Engineering
Poly(lactic acid) (PLA), a well-known biopolymer, is lacking in barrier properties and toughness. The research goal of this project is to look at the crystallinity of PLA when combined with metal organic framework (MOF). It is speculated that MOF has an effect on PLA chain mobility, and therefore crystallinity. In this study, aluminum MOF was added to PLA in varying concentrations (0, 0.5, 1, 2, 5, 10, and 20 wt%) to observe the crystallinity of the composite. The resulting PLA-Al-MOF composite films were characterized using differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and scanning electron …
Reducing Food And Packaging Waste Through Developing Edible Fruit Based Packaging Prototypes, Melanie Thatcher
Reducing Food And Packaging Waste Through Developing Edible Fruit Based Packaging Prototypes, Melanie Thatcher
Materials Engineering
Packaging is used to contain, preserve, protect, and advertise both manufactured and natural products. In 2013 it was reported that over thirty percent of solid waste in the United States was from packaging. One way to reduce the impact of packaging on the environment is to create a solution that is edible and sourced from a waste or secondary food product that is not currently being utilized. Food-contact packaging made from recycled materials must meet strict U.S. Food and Drug Administration (FDA) regulations to be utilized as raw material for packaging. Fruit pomace is a candidate material since it may …
Investigation Of Outlife Time On The Environmental Durability Of P2-Etched, Adhesively-Bonded Aluminum Alloys Using The Astm Wedge Test, Daniel Gross, Corey Sutton
Investigation Of Outlife Time On The Environmental Durability Of P2-Etched, Adhesively-Bonded Aluminum Alloys Using The Astm Wedge Test, Daniel Gross, Corey Sutton
Materials Engineering
P2 etchant is an environmentally-friendly aluminum etchant which has the potential to replace the Forest Products Laboratory (FPL) etchant as the industry standard. Environmental durability of adhesively-bonded aluminum surfaces etched using a paste version of the P2 etchant were tested using the Boeing-developed wedge test (ASTM D3762 - 03(2010)). This project specifically aimed to examine the relationship between outlife time (the time between etching and adhering) and the ability of bonded aluminum samples to pass the wedge test. Two aluminum alloys, 2024-T3 and 7075-T6, were wedge tested and the etched surfaces examined with an atomic force microscope (AFM) and a …
Improving Surface Roughness Of Optically Telegraphed Composite Laminations, Michael Smith
Improving Surface Roughness Of Optically Telegraphed Composite Laminations, Michael Smith
Materials Engineering
In collaboration with Watson Furniture, this project seeks to identify the cause of surface roughness on composite panels processed into commercial furnishings. The surface roughness was examined and measured using an optical microscope, a scanning electron microscope (SEM), and a profilometer. The SEM and optical microscope provided qualitative data on the surface roughness as well as the film build of each layer. After an initial characterization of the manufactured samples provided by Watson Furniture, additional samples were fabricated for testing using different manufacturing processes than those used by Watson Furniture. These samples were constructed in-house using raw materials provided by …
Effect Of Hydrogen Pick-Up And Release Behavior On The Tensile Properties Of Electroplated 4340m High-Strength Steel, Blake Daylor, Joshua Fisher, Alan Michelen Ruiz
Effect Of Hydrogen Pick-Up And Release Behavior On The Tensile Properties Of Electroplated 4340m High-Strength Steel, Blake Daylor, Joshua Fisher, Alan Michelen Ruiz
Materials Engineering
Hydrogen embrittlement of high-strength steel (4340M) was quantified through tensile testing and fractography (SEM). Three types of samples were obtained: rotating beam fatigue specimens, round (notched) tensile specimens, and flat panel specimens. In addition, three different plating types were analyzed (Ni, Cr, Cd-Ti) with a set of samples that was shot peened and a set that was not. Since some of the samples went through a hydrogen relief bake, another factor in our experiment was the amount of time it took for the samples to reach the baking process after they were electroplated (bake delay). There were three levels of …
Controlling Grain Size In Cold Worked And Annealed 1100 Aluminum To Optimize Ductility In Rocket Diaphragm Systems, Ryan Lewis, Bryce Simmons, Jessica Williams
Controlling Grain Size In Cold Worked And Annealed 1100 Aluminum To Optimize Ductility In Rocket Diaphragm Systems, Ryan Lewis, Bryce Simmons, Jessica Williams
Materials Engineering
Liquid propellant rocket diaphragms require extreme ductility. 1100 Aluminum is used for its high ductility, but the post-processing cold work and subsequent anneal result in excessively large grains. The effect of heat treatment and cold work on grain size in 1100 aluminum was explored. The samples were cold worked to 0, 5, 10, 15 and 30% using tensile elongation. The samples were then heat treated per AMS 2770 with either a "Steel Conduction" (1000 – 1150°F/min) or a "Production" (16 – 18°F/min) heating rate. The grain size of the samples were measured using the mean lineal intercept method. The grain …
Graduate Internship Report In Agricultural Education: Oakdale High School, Rebecca Jean Mendonza
Graduate Internship Report In Agricultural Education: Oakdale High School, Rebecca Jean Mendonza
Agricultural Education: Graduate Internship Reports
This internship report includes validation documents required in meeting the quality criteria for secondary-level programs of instruction in agriculture. The documents are concurrently used for the Agriculture Incentive Grant review process at Oakdale High School, conducted by representatives of the California Department of Education.
Graduate Internship In Agricultural Education: Santa Maria High School, Amanda L. Rodriguez
Graduate Internship In Agricultural Education: Santa Maria High School, Amanda L. Rodriguez
Agricultural Education: Graduate Internship Reports
This graduate internship report includes validation documents required in meeting the quality criteria for secondary-level programs of instruction in agriculture. The documents are concurrently used for the Agriculture Incentive Grant review process at Santa Maria High School conducted by representatives of the California Department of Education. The internship included the planning and development of a fully equipped agriscience laboratory to be utilized as a way to enhance the curriculum and instruction for various agriscience classes within the department.
Graduate Internship Report Agricultural Education: Patterson High School, Samantha Cahill
Graduate Internship Report Agricultural Education: Patterson High School, Samantha Cahill
Agricultural Education: Graduate Internship Reports
This internship and project report includes documentation required in meeting the quality criteria for secondary-level programs of instruction in agriculture. The documents are concurrently used for the Agriculture Incentive Grant review process at Patterson High School conducted by representatives of the California Department of Education. The supporting material includes information to receive state and local funding, outline the goals and objectives of the program, along with an overview of Patterson High School, the agriculture program and the community.
Remind, Keith Abdulla
Automatic Generation And Grading Of Programming Exercises, Andrew Dufrene
Automatic Generation And Grading Of Programming Exercises, Andrew Dufrene
Computer Science and Software Engineering
In our current age of technological advances, and rising education costs, it is becoming increasingly beneficial to use technology to aid in education, usually through automated lectures or grading. One missing feature from this automated education is complex grading and problem generation. The main objective of this project is to create a program that can automatically generate and grade problems of varying difficulties based on the topic of programming for loops. The project solution was created as a program designed for use in Dr. Clinton Staley’s Intelligent Homework System, which is used precisely for automated exercise grading and generation. Ultimately, …
A Rhetorical Criticism Of Blackfish: Making Waves In Orca Activism, Lindsay Beisheim
A Rhetorical Criticism Of Blackfish: Making Waves In Orca Activism, Lindsay Beisheim
Communication Studies
No abstract provided.
Accelerating Hash Grid And Screen-Space Photon Mapping In 3d Interactive Applications With Opencl, Nikolai Shkurkin
Accelerating Hash Grid And Screen-Space Photon Mapping In 3d Interactive Applications With Opencl, Nikolai Shkurkin
Computer Science and Software Engineering
Achieving interactive and realistic rendering is only possible with a combination of rendering algorithms, rendering pipelines, multi-core hardware, and parallelization APIs. This project explores and implements two photon mapping pipelines based on the work of Mara et. al [5] and Singh et. al [7] to achieve interactive rendering performance for a set of simple scenes using OpenCL and C++ to work with a GPU. In particular, both a 3D hash grid and a screen-space tiling algorithm are parallelized to accelerate photon lookup in order to compute direct and indirect lighting on visible surfaces in a scene. By using OpenCL with …