Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Structural Engineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 421 - 450 of 632

Full-Text Articles in Entire DC Network

Behavior Of Cfrp Plate In Simulated Iccp System Of Concrete Structures, Jihua Zhu, Miaochang Zhu, Ningxu Han, Feng Xing, Wei Liu, Luca Bertolini Jul 2014

Behavior Of Cfrp Plate In Simulated Iccp System Of Concrete Structures, Jihua Zhu, Miaochang Zhu, Ningxu Han, Feng Xing, Wei Liu, Luca Bertolini

International Conference on Durability of Concrete Structures

An innovative effort was made to utilize carbon fiber reinforced polymer (CFRP) plate as an anode in impressed current cathodic protection (ICCP) of reinforced concrete structure. The feasibility was explored by bonding CFRP strips to concrete and then applying protection current through CFRP strips to steel rebar in concrete. Service life and performance of CFRP plate were investigated in simulated ICCP systems with various configurations. Steel potential results confirmed that the steel rebar in concrete maintained at a satisfactory level with the applied protection current. It is shown that CFRP strips can be successfully used in various solutions as an …


Effects Of Stirrups On Bond Behavior Between Concrete And Corroded Steel Bars, Hongwei Lin, Yuxi Zhao, Ming Sun Jul 2014

Effects Of Stirrups On Bond Behavior Between Concrete And Corroded Steel Bars, Hongwei Lin, Yuxi Zhao, Ming Sun

International Conference on Durability of Concrete Structures

Steel corrosion leads to the deterioration of bond between concrete and steel bars. The serviceability and ultimate strength of concrete elements within RC structures are hence affected. Many researchers have studied the bond behavior of corroded steel bars. However, very few studies have investigated the effects of confinements on the degradation of bond strength. The present paper proposed a new kind of beam specimen based on which the effects of stirrups on degradation of bond were investigated. The test results proved that stirrups can effectively increase the bond strength between concrete and corroded steel bars.


Revised Model Of Chloride Diffusion In Concrete Bridge By Considering Complex Action Of Load And Chloride Binding Capacity, Yiqiang Xiang, Dongmei Guo Jul 2014

Revised Model Of Chloride Diffusion In Concrete Bridge By Considering Complex Action Of Load And Chloride Binding Capacity, Yiqiang Xiang, Dongmei Guo

International Conference on Durability of Concrete Structures

Coastal concrete bridges will suffer from deterioration of RC structural performance and resistance attenuation because of the chloride penetration and other environment factors. This article discusses current different chloride diffusion models and puts forward the revised model of chloride diffusion in concrete bridge by considering the complex action of load influence and chloride-binding capacity. Comparison of numerical predicted values and relative experimental tests show the presented chloride diffusion model to be more accurate. It provides a theoretical basis for the performance assessment and accurate prediction of the remaining life of highway concrete bridges.


Flexural Behavior Of Rc Beams Under Combined Effects Of Acid–Salt Mist And Carbon Dioxide, Wu Yuan-Zhou, Lv Heng-Lin, Fang Zhong-Nian Jul 2014

Flexural Behavior Of Rc Beams Under Combined Effects Of Acid–Salt Mist And Carbon Dioxide, Wu Yuan-Zhou, Lv Heng-Lin, Fang Zhong-Nian

International Conference on Durability of Concrete Structures

The coupling effects of hydrochloric acid mist, carbon dioxide, and salt mist rich in Cl– and SO42– on the degradation of reinforcement concrete (RC) beams were researched with the simulation of colliery ground environment (CGE) and experimental investigation. The results indicated that carbonation of concrete and corrosion of rebar increased slowly as the maximum width of crack became <0.5 mm. Meanwhile, the flexural carrying capacity of the deteriorated beam decreased slightly, while the concrete strength got a small increase first and a large decrease of more than 20% quickly. As the width of crack exceeded 0.5 mm, each target changed rapidly except the carbonation depth. Because of the interaction of deteriorated concrete and corroded rebar, the crack width, and flexural behavior of the beams have discrete correlation with the corrosion of rebar. The failure mode of beams changed from the crushing of compression concrete to the yielding of rebar.


Development Of Bridge Girder Movement Criteria For Accelerated Bridge Construction, Genda Chen, Yi Bao Jun 2014

Development Of Bridge Girder Movement Criteria For Accelerated Bridge Construction, Genda Chen, Yi Bao

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

End diaphragms connect multiple girders to form a bridge superstructure system for effective resistance to earthquake loads. Concrete girder bridges that include end diaphragms consistently proved to perform well during previous earthquake events. However, whether concrete bridges without end diaphragms are definitively inadequate in seismic performance is yet to be answered. The 2010 Chile Earthquake indicated that properly designed bridge girders and their lateral movement stoppers (shear keys) may perform equally well with those with end diaphragms. In this report, a feasibility study on the design of girder bridges without end diaphragms is presented. This study is particularly significant in …


Splice Performance Evaluation Of Enamel-Coated Rebar For Structural Safety, Genda Chen, Chenglin Wu Jun 2014

Splice Performance Evaluation Of Enamel-Coated Rebar For Structural Safety, Genda Chen, Chenglin Wu

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

This report summarizes the findings and results from an experimental study of vitreous enamel coating effects on the bond strength between deformed rebar and normal strength concrete. A total of 24 beam splice specimens were tested under four-point loading with four parameters investigated: bar size, lap splice length, coating, and confinement conditions. As the splice length increases, the ratio of bond strength between coated rebar and black rebar first increases from 1.0 to a maximum value of 1.44, and then decreases to 1.0. The maximum bond strength ratio corresponds to the near initial yielding of coated rebar. On the average, …


Nondestructive Evaluation Of Mechanically Stabilized Earth Walls With Frequency-Modulated Continuous Wave (Fm-Cw) Radar, Mohammad Tayeb Ahmad Ghasr, Yi Bao, Kuang Ying, K. M. Combs, R. Zoughi, Genda Chen Jun 2014

Nondestructive Evaluation Of Mechanically Stabilized Earth Walls With Frequency-Modulated Continuous Wave (Fm-Cw) Radar, Mohammad Tayeb Ahmad Ghasr, Yi Bao, Kuang Ying, K. M. Combs, R. Zoughi, Genda Chen

Electrical and Computer Engineering Faculty Research & Creative Works

Effective techniques for a nondestructive evaluation of mechanically stabilized earth (MSE) walls during normal operation or immediately after an earthquake event are yet to be developed. MSE walls often have a rough surface finishing for the purpose of decoration and are reinforced with both horizontal and vertical steel bars. Two wide-band microwave inspection approaches were investigated for detecting and evaluating characteristics of materials behind an MSE wall section. The first approach used spot measurements with a wide-band frequency-modulated continuous wave (FM-CW) radar system. While effective to penetrate through mortar blocks in the laboratory, the radar system was found to have …


Corrosion-Resistant Glasses For Steel Enamels, Richard K. Brow, Signo Tadeu Dos Reis, Michael L. Koenigstein, Genda Chen Mar 2014

Corrosion-Resistant Glasses For Steel Enamels, Richard K. Brow, Signo Tadeu Dos Reis, Michael L. Koenigstein, Genda Chen

Materials Science and Engineering Faculty Research & Creative Works

A cementitious composite material wherein glass-coated steel rods are positioned in a cementitious matrix. The glass composition for coating the steel reinforcing rods includes between about 33-45 weight percent SiO2, 13.5-19.5 weight percent B2O3, 3.5-4.6 weight percent Al2O3, 4.0-13.5 weight percent K2O, 5.5-15.5 weight percent ZrO2, 8.6-15.9 weight percent Na2O, 4.6-5.1 weight percent CaO, 0.6-0.7 weight percent MnO2, 1.0-1.0 weight percent NiO, and 1.0-1.1 weight percent CoO. The glass composition is typically in compression on the rods at ambient temperatures, has a …


Mechanical And Transport Properties Of Alkali-Activated Natural Pozzolans As Sustainable Binders, Brittany Radke Jan 2014

Mechanical And Transport Properties Of Alkali-Activated Natural Pozzolans As Sustainable Binders, Brittany Radke

Calvert Undergraduate Research Awards

OPC production accounts for 5 to 7% of the global carbon dioxide (CO2) emissions, contributing to global warming. The desire to reduce CO2 emissions and produce more durable concrete has given impetus to search for new binders. It is suggested that alkali-activated natural pozzolans have the potential for use as a sustainable replacement for OPC in concrete.

The current study presented herein evaluated fresh, mechanical, and transport properties of alkali-activated natural pozzolan mortars containing various concentrations of sodium hydroxide solutions as an alkaline activator. To this aim, alkali-activated natural pozzolan mortars were made with concentrations of sodium …


Role Of Force Resultants Interaction On Fiber Reinforced Concrete, Titchenda Chan Jan 2014

Role Of Force Resultants Interaction On Fiber Reinforced Concrete, Titchenda Chan

Electronic Theses and Dissertations

Ultra-high performance concrete (UHPC) is a recently developed concrete gaining a lot of interest worldwide, and a lot research has been conducted to determine its material properties. UHPC is known for its very high strength and high durability. Association Francaise de Genie Civil (AFGC) has defined UHPC as a concrete exhibiting compressive strength greater than 150 MPa (22 ksi). To utilize the full compressive strength of UHPC, complementary tension reinforcement is required. A recent research study to find light weight yet high strength alternative deck systems for Florida movable bridges demonstrated that a composite UHPC and high strength steel (HSS) …


A Technical And Economic Appraisal Of Insulation Retrofits, Niamh O'Brien Jan 2014

A Technical And Economic Appraisal Of Insulation Retrofits, Niamh O'Brien

Theses

The main aim of this literature review is to further develop the project brief and to examine what research has previously been undertaken in the field of thermal conductivity and retrofitting insulation. The basis of this project is to determine the effect of moisture in domestic cavity walls on the effectiveness of retrofitted insulation. The research began by highlighting the reasoning behind the need for insulation within domestic dwellings within Ireland and the guiding legislation in place in relation to this. Carrying on from this, the current methods used to retrofit insulation were examined, along with the types of insulation …


Testing And Analysis Of An Alternative Connection Method In Closed Panel Timber Frame Domestic Construction, Brendan Towey Jan 2014

Testing And Analysis Of An Alternative Connection Method In Closed Panel Timber Frame Domestic Construction, Brendan Towey

Masters

Construction practices continue to evolve in tandem with the requirements for more energy efficient buildings, materials and construction methods. This steady and progressive move towards the development of the industry and its products comes, not in leaps and bounds, but in incremental advances across all areas of construction. The research detailed in this project is one such advancement. Timber frame construction has been in existence for centuries and its tried and tested methods have been utilised worldwide in both domestic and industrial building. In recent times, standard open panel timber frame construction has been enhanced by the development of closed …


Smart Rocks And Wireless Communication System For Real-Time Monitoring And Mitigation Of Bridge Scour -- A Proof-Of-Concept Study, Genda Chen, David Pommerenke, Y. Rosa Zheng, Andriy V. Radchenko, Yan Tang, Brandon P. Schafer, Ying Huang, Z. L. Yang Dec 2013

Smart Rocks And Wireless Communication System For Real-Time Monitoring And Mitigation Of Bridge Scour -- A Proof-Of-Concept Study, Genda Chen, David Pommerenke, Y. Rosa Zheng, Andriy V. Radchenko, Yan Tang, Brandon P. Schafer, Ying Huang, Z. L. Yang

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

This study aims to integrate commercial measurement and communication components into a scour monitoring system with magnets or electronics embedded in smart rocks, and evaluate and improve its performance in laboratory and field conditions for the movement of smart rocks. Properly-designed smart rocks were found to be automatically rolled into the very bottom of a scour hole and can give critical information about the maximum scour depth and effectiveness of rip-rap mitigation strategies. Four types of smart rock technologies were investigated in this proof-of-concept phase of study, including passive with embedded magnets, active with magneto-inductive communication, active with controllable magnet …


Improvement In Performance Of Zno Based Dsc Prepared By Spraying Method, Rangga Winantyo, Devinda Liyanage, Kenji Murakami Aug 2013

Improvement In Performance Of Zno Based Dsc Prepared By Spraying Method, Rangga Winantyo, Devinda Liyanage, Kenji Murakami

Makara Journal of Technology

This paper reports the effect of TiCl4 on the performance of ZnO based DSC. ZnO was used due to its stability against photo-corrosion and photochemical properties similar to TiO2. Thin films of nanocrystalline ZnO were deposited on transparent conducting oxide glass using spray method. The ZnO films were treated using TiCl4. The cell’s efficiency was found to be 2.5% with TiCl4 post-treatment and 1.9% without TiCl4 post-treatment.


Fatigue Life Prediction Of The Keel Structure Of A Tsunami Buoy Using Spectral Fatigue Analysis Method, Angga Yustiawan, Ketut Suastika, Wibowo Harso Nugroho Aug 2013

Fatigue Life Prediction Of The Keel Structure Of A Tsunami Buoy Using Spectral Fatigue Analysis Method, Angga Yustiawan, Ketut Suastika, Wibowo Harso Nugroho

Makara Journal of Technology

One of the components of the Indonesia Tsunami Early Warning System (InaTEWS) is a surface buoy. The surface buoy is exposed to dynamic and random loadings while operating at sea, particularly due to waves. Because of the cyclic nature of the wave load, this may result in a fatigue damage of the keel structure, which connects the mooring line with the buoy hull. The operating location of the buoy is off the Java South Coast at the coordinate (10.3998 S, 108.3417 E). To determine the stress transfer function, model tests were performed, measuring the buoy motions and the stress at …


Structural Reliability Analysis Of Corroded Steel Girder Bridge, Mohammed Shaalan Al Badran Jul 2013

Structural Reliability Analysis Of Corroded Steel Girder Bridge, Mohammed Shaalan Al Badran

Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research

The natural aging, environmental impact, and appropriate design are certainly playing a serious role in safety of the bridges function. The functional safety of bridge constitutes a prime element of the transportation system serving commuters, passengers and freight. According to Federal Highway Administration, the steel bridges share represents a large amount of the United States’ bridges. In last century, the collapse of both the Silver Bridge at Point Pleasant, West Virginia over the Ohio River on December 15, 1967 and over the Mianus River Bridge in Connecticut on June 28, 1983 showed that steel corrosion has been the leading reason …


Public Works Projects As Vehicles For Engineering Education And Outreach, Shannon Weiss, David Heil, Thalia Anagnos Jun 2013

Public Works Projects As Vehicles For Engineering Education And Outreach, Shannon Weiss, David Heil, Thalia Anagnos

Faculty Publications

America is built on small and large feats of public works engineering that, although often taken for granted, affect almost every aspect of our daily lives. So how can we celebrate these marvels of utilitarian infrastructure and use them to teach public audiences about the engineering principles, materials, and human innovations that make them possible? This case study will share how one project addressed these questions by leveraging informal learning strategies, multi-agency collaborations, and new media technologies to explain the history and engineering of one of the world’s most recognizable public work sites: the Golden Gate Bridge. This paper will …


Reliability-Based Design Optimization Of Concrete Flexural Members Reinforced With Ductile Frp Bars, Bashar Behnam, Christopher D. Eamon Jun 2013

Reliability-Based Design Optimization Of Concrete Flexural Members Reinforced With Ductile Frp Bars, Bashar Behnam, Christopher D. Eamon

Civil and Environmental Engineering Faculty Research Publications

In recent years, ductile hybrid FRP (DHFRP) bars have been developed for use as tensile reinforcement. However, initial material costs regain high, and it is difficult to simultaneously meet strength, stiffness, ductility, and reliability demands. In this study, a reliability-based design optimization (RBDO) is conducted to determine minimum cost DHFRP bar configurations while enforcing essential constraints. Applications for bridge decks and building beams are considered, with 2, 3, and 4-material bars. It was found that optimal bar configuration has little variation for the different applications, and that overall optimized bar cost decreased as the number of bar materials increased.


Fatigue Testing And Data Analysis Of Welded Steel Cruciform Joints, Alina Shrestha May 2013

Fatigue Testing And Data Analysis Of Welded Steel Cruciform Joints, Alina Shrestha

LSU New Orleans Theses and Dissertations

In this study, ABS Publication 115, “Guidance on Fatigue Assessment of Offshore Structures” is briefly reviewed. Emphasis is on the S-N curves based fatigue assessment approach of non-tubular joints, and both size and environment effects are also considered. Further, fatigue tests are performed to study the fatigue strength of load-carrying and non-load-carrying steel cruciform joints that represent typical joint types in marine structures. The experimental results are then compared against ABS fatigue assessment methods, based on nominal stress approach, which demonstrates a need for better fatigue evaluation parameter. A good fatigue parameter by definition should be consistent and should correlate …


Precast/Prestressed Concrete Truss-Girder For Roof Applications, Peter S. Samir May 2013

Precast/Prestressed Concrete Truss-Girder For Roof Applications, Peter S. Samir

Department of Construction Engineering and Management: Dissertations, Theses, and Student Research

Steel trusses are the most popular system for supporting long span roofs in commercial buildings, such as warehouses and aircraft hangars. There are several advantages of steel trusses, such as lightweight, ease of handling and erection, and geometric flexibility. However, they have some drawbacks, such as high material and maintenance cost, and low fire resistance. In this paper, a precast concrete truss is proposed as an alternative to steel trusses for spans up to 160 ft. without intermediate supports. The proposed design is easy to produce and has lower construction and maintenance costs than steel trusses. The proposed design is …


North American Standard For Cold-Formed Steel Framing -- General Provisions, 2012 Edition, American Iron And Steel Institute Apr 2013

North American Standard For Cold-Formed Steel Framing -- General Provisions, 2012 Edition, American Iron And Steel Institute

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

No abstract provided.


North American Standard For Cold-Formed Steel Framing -- Product Data, 2012 Edition, American Iron And Steel Institute Apr 2013

North American Standard For Cold-Formed Steel Framing -- Product Data, 2012 Edition, American Iron And Steel Institute

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

No abstract provided.


North American Standard For Cold-Formed Steel Framing -- Truss Design, 2012 Edition, American Iron And Steel Institute Apr 2013

North American Standard For Cold-Formed Steel Framing -- Truss Design, 2012 Edition, American Iron And Steel Institute

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

No abstract provided.


Bringing To Life The World’S Tallest Structure, Jonathan Weigand Mar 2013

Bringing To Life The World’S Tallest Structure, Jonathan Weigand

Pursuit - The Journal of Undergraduate Research at The University of Tennessee

Intended as the centerpiece of constructional developments in Dubai, the Burj Khalifa now stands as the tallest building ever constructed. The uniquely designed foundation consists of a concrete raft supported by a cast-in-place pile system protected by waterproofing membrane to inhibit corrosion. The structural design integrates high-performance reinforced concrete and steel and incorporates an engineered “Y” shape that limits the lateral wind pressure on the building. Engineers applied the latest advancements in high-rise technology to develop an optimized construction plan that consisted of segmented tasks that promoted the staff to work at a quick yet manageable pace. This article details …


Specification For The Design Of Cold-Formed Steel Structural Members, American Iron And Steel Institute Mar 2013

Specification For The Design Of Cold-Formed Steel Structural Members, American Iron And Steel Institute

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

No abstract provided.


Analysis Of Alternative Ductile Fiber-Reinforced Polymer Reinforcing Bar Concepts, Bashar Behnam, Christopher D. Eamon Mar 2013

Analysis Of Alternative Ductile Fiber-Reinforced Polymer Reinforcing Bar Concepts, Bashar Behnam, Christopher D. Eamon

Civil and Environmental Engineering Faculty Research Publications

Steel-reinforced concrete structural components are often associated with significant maintenance costs as a result of reinforcement corrosion. To mitigate this problem, fiber-reinforced polymer (FRP) bars have been used in place of traditional steel reinforcement for some applications. The non-ductile response of typical FRP bars is a concern, however. To overcome this problem, hybrid ductile FRP (HDFRP) bars have been developed for use in concrete flexural members with resulting ductility indices similar to sections reinforced with steel. In this study, five different HDFRP bar concepts are analyzed and compared in terms of ductility, stiffness, and relative cost. Of primary interest is …


Resistance Factors For Ductile Frp-Reinforced Concrete Flexural Members, Bashar Behnam, Christopher D. Eamon Jan 2013

Resistance Factors For Ductile Frp-Reinforced Concrete Flexural Members, Bashar Behnam, Christopher D. Eamon

Civil and Environmental Engineering Faculty Research Publications

To prevent damage caused by corroding reinforcement, fiber reinforced polymer (FRP) reinforcing bars have been used in place of steel in a relatively small but increasing number of structures in the civil infrastructure. A concern with the use of traditional FRP bars, however, is the resulting lack of ductility. This problem has been overcome with the development of a new generation of composite reinforcement, ductile hybrid FRP (DHFRP) bars. However, standards that address the design of DHFRP bars are unavailable, and appropriate resistance factors for the use of DHFRP reinforcement are unknown. In this study, a reliability analysis is conducted …


Characterization Of Impact Damage And Fiber Reinforced Polymer Repair Systems For Metallic Utility Poles, Cara Johnson Jan 2013

Characterization Of Impact Damage And Fiber Reinforced Polymer Repair Systems For Metallic Utility Poles, Cara Johnson

Electronic Theses and Dissertations

Previous studies have demonstrated that the behavior of fiber reinforced polymers (FRPs) bonded to metallic utility poles are governed by the following failure modes; yielding of the metallic substrate, FRP tensile rupture, FRP compressive buckling, and debonding of FRP from the substrate. Therefore, an in situ method can be devised for the repair of utility poles, light poles, and mast arms that returns the poles to their original service strength. This thesis investigates the effect of damage due to vehicular impact on metallic poles, and the effectiveness of externally-bonded FRP repair systems in restoring their capacity. Damage is simulated experimentally …


Experimental And Numerical Investigations On Bond Durability Of Cfrp Strengthened Concrete Members Subjected To Environmental Exposure, Haider Al-Jelawy Jan 2013

Experimental And Numerical Investigations On Bond Durability Of Cfrp Strengthened Concrete Members Subjected To Environmental Exposure, Haider Al-Jelawy

Electronic Theses and Dissertations

Fiber reinforced polymer (FRP) composites have become an attractive alternative to conventional methods for external-strengthening of civil infrastructure, particularly as applied to flexural strengthening of reinforced concrete (RC) members. However, durability of the bond between FRP composite and concrete has shown degradation under some aggressive environments. Although numerous studies have been conducted on concrete members strengthened with FRP composites, most of those studies have focused on the degradation of FRP material itself, relatively few on bond behavior under repeated mechanical and environmental loading. This thesis investigates bond durability under accelerated environmental conditioning of two FRP systems commonly employed in civil …


Evaluating The Use Of Recycled Concrete Aggregate In French Drain Applications, Zachary Behring Jan 2013

Evaluating The Use Of Recycled Concrete Aggregate In French Drain Applications, Zachary Behring

Electronic Theses and Dissertations

Recycled concrete aggregate (RCA) is often used as a replacement of virgin aggregate in road foundations (base course), embankments, hot-mix asphalt, and Portland cement concrete. However, the use of RCA in exfiltration drainage systems, such as French drains, is currently prohibited in many states of the U.S. The French drain system collects water runoff from the road pavement and transfers to slotted pipes underground and then filters through coarse aggregate and geotextile. The primary concerns with using RCA as a drainage media are the fines content and the precipitation of calcium carbonate to cause a reducing in filter fabric permittivity. …