Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Engineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 120691 - 120720 of 121078

Full-Text Articles in Entire DC Network

Test 216: Allis-Chalmers Model M, Nebraska Tractor Test Lab Jan 1933

Test 216: Allis-Chalmers Model M, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 219: Massey-Harris "3-4 Plow", Nebraska Tractor Test Lab Jan 1933

Test 219: Massey-Harris "3-4 Plow", Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 218: Caterpiller "Diesel 75", Nebraska Tractor Test Lab Jan 1933

Test 218: Caterpiller "Diesel 75", Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 215: Allis-Chalmers Special K, Nebraska Tractor Test Lab Jan 1933

Test 215: Allis-Chalmers Special K, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 212: Mccormick-Deering Farmall "F-12", Nebraska Tractor Test Lab Jan 1933

Test 212: Mccormick-Deering Farmall "F-12", Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


A Comparative Study Of The American Society For Testing Materials Spall Test And The Federal Specifications Spall Test, Justus Jordan Beinlich Jan 1933

A Comparative Study Of The American Society For Testing Materials Spall Test And The Federal Specifications Spall Test, Justus Jordan Beinlich

Bachelors Theses

"Commercial brands of fireclay brick will be tested with both the American Society for Testing Materials and the Federal Specifications Spall Tests in order to determine whether the two tests are consistent in the indication of resistance to spalling. It is suggested that the properties of a refractory affecting thermal spalling are reversible thermal expansion, elasticity, heat transfer, plastic flow, and strength. It is hoped that it will be possible to explain the discrepancies that may arise in the results of this work in terms of the above physical properties or else find a reasonable agreement between the two tests"--Introduction, …


The Replacement Of Calcium Carbonate With Calcium Chloride And Calcium Fluoride In A Whiteware Body, Charles Richard Rosenbaum Jan 1933

The Replacement Of Calcium Carbonate With Calcium Chloride And Calcium Fluoride In A Whiteware Body, Charles Richard Rosenbaum

Bachelors Theses

"In the steel industry it is a common metallurgical practice to add fluospar sic (CaF₂), to a slag to render it more fluid. Ladoo states that the fluospar sic , thus added, forms eutechtics with the silica, alumina, calcium and barium sulfates, rendering them more fusible. The fluospar sic does not decompose, but forms solutions or eutechtics with other substances in the slag. He further states that calcium chloride (CaCl₂) has been used for this purpose but is apparently not as active, necessitating larger quantities per charge. It is also probably more expensive. Calcium carbonate (CaCO₃) is commonly used as …


The Relation Between The Mean Molecular Weight And The Absolute Viscosity Of Lubricating Oils, John Isler Moore Jan 1933

The Relation Between The Mean Molecular Weight And The Absolute Viscosity Of Lubricating Oils, John Isler Moore

Masters Theses

"Of all the properties required of a good lubricant the most important is that of the viscosity at the temperature of its use. Most lubricants consist of oils blended or compounded together in such a way as to produce an oil of a desired viscosity, falling in the special group of viscosities expressed by the Society of Automotive Engineers in their tabulations.

There have been several methods developed to enable the refiner to blend quickly and efficiently although Bell stated that the methods were largely that of trial and error. Herschel formed a chart for blending by the logarithmic rule …


Piles And Pile Driving, Robert W. Van Houten Jun 1932

Piles And Pile Driving, Robert W. Van Houten

Theses

This thesis on the subject of "Piles and Pile Driving" has been written to fulfill one of the requirements for the granting of the degree of Civil Engineer by the Newark College of Engineering. The material contained in this thesis has been gleaned from many books, catalogs, magazines and from the author's own experience. Much still needs to be accomplished in the field of research but this can be done only through the cooperation of the companies who are engaged in this work and have the equipment necessary for making many tests under actual field conditions.

The author wishes to …


The Recovery Of Copper In Sulphide Ores By Roasting, Leaching, And Electrolysis, Jack S. Greenough Jun 1932

The Recovery Of Copper In Sulphide Ores By Roasting, Leaching, And Electrolysis, Jack S. Greenough

Bachelors Theses and Reports, 1928 - 1970

Sulphide ores of copper are insoluble in dilute sulphuric acid leaching solutions, but a very high extraction can be obtained if the copper ore is in the oxidized condition. The problem is to convert the sulphide into the oxide form. This can be done by giving the sulphide ore an oxidizing-sulphatizing roast. Copper sulphate is soluble in water, so acid will be saved in the leaching process if copper sulphate is present. The iron in the copper sulphide ores is present as pyrite, or in combinations as bornite, or chalcopyrite.


Some Notes On The Composition Of "Copper Pitch", Richard R. Matthew Jun 1932

Some Notes On The Composition Of "Copper Pitch", Richard R. Matthew

Bachelors Theses and Reports, 1928 - 1970

A supply of so-called "copper pitch" ore was received by the Montana Bureau of Mines and Geology in response to a request by them from a resident of Kalispell, who had previously sent a specimen to the Bureau for a mineralogical analysis.

Since this material was little known and had apparently received but little study under a reflec­ting microscope, it was thought that such a study might throw some light on the mineralogical and chemical composition of the material.


The Aplitic Body Bordering Roosevelt Drive South Of Butte, Montana, Edward B. Trueworthy Jr. Jun 1932

The Aplitic Body Bordering Roosevelt Drive South Of Butte, Montana, Edward B. Trueworthy Jr.

Bachelors Theses and Reports, 1928 - 1970

The area studied consists of a large body of aplite situated 12 miles south of Butte. It extends eastward almost to the Butte-Pipestone road, southward to Lime Kiln Hill and westward a distance of 3000 feet.

The petrographic work was supplemented by a map of the area. Special attention was given to those frequent "Limonite Specks" found in the aplite.


Joint Planes In The Rhyolites Of The Butte District, Montana, John B. Hopkins Jun 1932

Joint Planes In The Rhyolites Of The Butte District, Montana, John B. Hopkins

Bachelors Theses and Reports, 1928 - 1970

The problem herein discussed deals with the pointing planes found in the area of rhyolite located in the northwestern portion of the Butte District. The question to be determined was whether or not the pointing planes in the rhyolites could be class­ified with the Butte Ore fissure systems.


A Bentonite Deposit Near Warm Springs, Montana, R. H. Larson Jun 1932

A Bentonite Deposit Near Warm Springs, Montana, R. H. Larson

Bachelors Theses and Reports, 1928 - 1970

This report deals with a bentonite deposit recently developed, approximately seven miles northeast of Warm Springs, Montana. A group of claims have been staked on the deposit and are owned by the Lincoln Mining Company of Anaconda, Montana. The company also has several claims prospected for silver one mile from its present site of operations, but the silver prospects have failed to produce. The bentonite deposit was discovered incidentally during the course of other development work, and at present two adits have been driven into the side of a mountain, each crosscutting a vein-like mass of bentonite varying from two …


Asphalt Emulsions, Albert Joseph Krause Jun 1932

Asphalt Emulsions, Albert Joseph Krause

Bachelors’ Theses

During the past decade the improvement of our primary or trunk line highways and the streets of our business as well as the principal residence streets of our towns and cities has gone forward at a rapid pace. For the most part these improvements have consisted of high-type, costly pavements which have in some cases placed excessive burdens on our public treasuries and the tax-payers who are assessed for them.


The Rate Of Precipitation Of Copper Aluminide In The Silver Rich Silver-Copper-Aluminum Alloys, Thomas Finley Mcbride May 1932

The Rate Of Precipitation Of Copper Aluminide In The Silver Rich Silver-Copper-Aluminum Alloys, Thomas Finley Mcbride

Bachelors Theses and Reports, 1928 - 1970

In order to determine the best annealing temperature at which to age-harden the alloys, hardness tests on speci­men annealed for different lengths of time at different temperatures were made.


The Effect Of Hydrogen Overvoltage On The Electrolytic Deposition Of Zinc, John M. Munzenrider, Kenneth O. Sweeney May 1932

The Effect Of Hydrogen Overvoltage On The Electrolytic Deposition Of Zinc, John M. Munzenrider, Kenneth O. Sweeney

Bachelors Theses and Reports, 1928 - 1970

In the deposition of metallic zinc by electro­lysis from neutral or acid solution, little difficulty is experienced provided certain impurities are absent from the electrolyte. The use of the process has long been considered as a potential source, patents on the process having been issued as early as 1880. However, the early experimenters failed to realize the importance of impurities in the electrolyte, and for this reason, the process suffered several severe setbacks when commercial plants were built.


The Electrolytic Deposition Of Chromium Upon Aluminum, E. Fults, L. D. Voerge May 1932

The Electrolytic Deposition Of Chromium Upon Aluminum, E. Fults, L. D. Voerge

Bachelors Theses and Reports, 1928 - 1970

The purpose or this investigation is primarily to determine the best conditions for plating chromium on aluminum. The work was carried out with the hope of obtaining coherent deposits, and of determin­ing the conditions under which such deposits may be duplicated.


Fundamentals Of Bridge Design, Albert C. Kalmbach May 1932

Fundamentals Of Bridge Design, Albert C. Kalmbach

Bachelors’ Theses

Man's earliest communication followed: water routes. Our prehistoric ancestors, evidence shows, fashioned boats and rafts which enabled them to travel along the rivers, and later to sail the seas. Following history through the years we will find man always developing theater routes for transportation before other methods. The early colonies in our America were along the coastal rivers; the Ohio and Mississippi river valleys were first settled in the interior.


Test 205: Caterpiller Model 20, Nebraska Tractor Test Lab Jan 1932

Test 205: Caterpiller Model 20, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 202: Cletrac Model 15, Nebraska Tractor Test Lab Jan 1932

Test 202: Cletrac Model 15, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 206: Caterpiller Model 35, Nebraska Tractor Test Lab Jan 1932

Test 206: Caterpiller Model 35, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 200: Allis Chalmers L, Nebraska Tractor Test Lab Jan 1932

Test 200: Allis Chalmers L, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 208: Caterpiller Diesel, Nebraska Tractor Test Lab Jan 1932

Test 208: Caterpiller Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 201: Cletrac Model 25, Nebraska Tractor Test Lab Jan 1932

Test 201: Cletrac Model 25, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 203: Caterpiller Model 25, Nebraska Tractor Test Lab Jan 1932

Test 203: Caterpiller Model 25, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 204: Caterpiller Model 50, Nebraska Tractor Test Lab Jan 1932

Test 204: Caterpiller Model 50, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 207: Caterpiller Model 15, Nebraska Tractor Test Lab Jan 1932

Test 207: Caterpiller Model 15, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 209: Caterpiller Model 65, Nebraska Tractor Test Lab Jan 1932

Test 209: Caterpiller Model 65, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 210: Mccormick-Deering Model W 30, Nebraska Tractor Test Lab Jan 1932

Test 210: Mccormick-Deering Model W 30, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …