Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Engineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 12061 - 12090 of 14334

Full-Text Articles in Entire DC Network

Study Of Marine Biocorrosion Using Afm And Molecular Techniques, Herbert H.P.Fang, Lichong Xu, Tong Zhang May 2003

Study Of Marine Biocorrosion Using Afm And Molecular Techniques, Herbert H.P.Fang, Lichong Xu, Tong Zhang

Journal of Electrochemistry

Biofilm is ubiquitous in nature.However,corrosin caused by biofilm is still by and large overlooked. This presentation is to demonstrate the applications of several newly developed analytical techniques in chemisrty and microbiology for the study of marine biocorrosion on steel. AFM(atomic force microscopy) was applied to investigate the initial formation mechanism of biofilm and the degree of corrosion of steel in polluted seawater. DNA/RNA-related molecular techniques were used to analyze the microbial composition corrosive biofilm. Results showed that microbial corrosion began within six days, and the corroded volume in the increased as a power function of time with an index 2.83. …


Selective Corrosion In Duplex Stainless Steel, Wen-Ta Tsai, Kuen-Ming Tsai, Chang-Jian Lin, Yan Fu May 2003

Selective Corrosion In Duplex Stainless Steel, Wen-Ta Tsai, Kuen-Ming Tsai, Chang-Jian Lin, Yan Fu

Journal of Electrochemistry

In duplex stainless steel, the two constituent phases, namely ferritic (α) and austenitic (γ) phases, have different crystal structure and chemical composition. They may thus exhibit different corrosion resistances in aqueous environment. In this investigation, an electrochemical technique with spatial resolution was employed to measure the potential difference between these two constituent phases in 2205 duplex stainless steel. Image analyzing techniques were also used to examine the preferential corrosion between α and γ phases. The experimental results showed that ferrite had a higher potential than austenite in 0.01 mol/L NaCl solution. In 2 mol/L H2SO4+x mol/L …


Electrochemical Monitoring On The Deactivation Of A Metallic Oxide Anode, Li-Kun Xu, Shi-Zhe Song, Ting-Yong Wang, Guang-Zhang Chen May 2003

Electrochemical Monitoring On The Deactivation Of A Metallic Oxide Anode, Li-Kun Xu, Shi-Zhe Song, Ting-Yong Wang, Guang-Zhang Chen

Journal of Electrochemistry

The process of accelerated life test of an IrO2/Ta2O5 coated titanium anode was monitored using cyclic voltammetry and electrochemical impedance spectroscopy. The vatiation with electrolysis time of anodic voltammetric charge Q*, the double layer capacitance Cdl,the oxide film resistance Rf and the charge transfer resistance Rct for oxygen evolution was measured. A deactivation mechanism was proposed based on the observation results.


Corrosion Behavior Of Reinforcing Steel In Concrete Subjected To Chloride Contamination By Eis, Rong-Gang Hu, Rong-Gui Du, Chang-Jian Lin May 2003

Corrosion Behavior Of Reinforcing Steel In Concrete Subjected To Chloride Contamination By Eis, Rong-Gang Hu, Rong-Gui Du, Chang-Jian Lin

Journal of Electrochemistry

Electrochemical impedance spectroscopy(EIS) was employed to study the influence of chloride on the corrosion behavior of reinforcing steel in concrete. In Nyquist plot, the spectrum consists of two semicircles, indicating that the reinforced concrete system contained two time constants,one derived from electrical double layer of reinforcing steel and the other from the deposition film of concrete layer. The depressed semicircle in lower frequency featured the non-faradic behavior of the electrical double layer (EDL) deviated from idea capacitor due to diffusive effect which was attributed to the surface roughness of rebar and the inhomogenity of concrete layer. Then the EDL was …


Corrosion Behavior Of Mg1.85Mm0.15Ni Hydrogen Storage Alloy Modified By Electroless Cu In Ch3Ohâ·H2O Solutions, Hua-Bin Yang, Hai-Chang Zhang, Hua Sun, Xiao-Dan Wang, Zuo-Xiang Zhou May 2003

Corrosion Behavior Of Mg1.85Mm0.15Ni Hydrogen Storage Alloy Modified By Electroless Cu In Ch3Ohâ·H2O Solutions, Hua-Bin Yang, Hai-Chang Zhang, Hua Sun, Xiao-Dan Wang, Zuo-Xiang Zhou

Journal of Electrochemistry

The corrosion behavior of the Mg1.85Mm0.15Ni (Mm:Ce-rich mischmetal) alloy modified by electroless Cu coating in different CH3OH-H2O solutions has been investigated by potentiodynamic polarization and electrochemical impedance spectroscopy. These results showed that the corrosion behavior was improved after electroless Cu. The potentiodynamic polarization and electrochemical impedance spectroscopy results showed that the alloy electrode had more promising anti-corrosion behavior after coated in a 40%CH3OH-H2O solution. The values of corrosion current density and electrode reaction resistance were 5.6 mA·cm-2 (11.7 mA·cm-2 for uncoated alloy electrode) and 22.25 Ω·cm …


Corrosion Prediction Of Carbon Steel In Concentrated Lithium Bromide Solutions At High Temperature Using Bp Neural Network, Nai-Bao Huang, Cheng-Hao Liang May 2003

Corrosion Prediction Of Carbon Steel In Concentrated Lithium Bromide Solutions At High Temperature Using Bp Neural Network, Nai-Bao Huang, Cheng-Hao Liang

Journal of Electrochemistry

Neutral network model has been developed for the computation of corrosion rate of carbon steel in LiBr solutions.The results indicate that the model is capable of reproducing the effects of changes in alkalinity, temperatures, LiBr and Na2MoO4 concentrations on the rates of general corrsion and good agreement between calculated and experimental corrosion rate is obtained. The model can be used to satisfactorily predict the corrosion rate of carbon steel in different concentrations of LiBr solutions containing different inhibitors at different temperatures. It also provides a novel method for corrosion monitoring of metals used in LiBr absorption chiller.


Development Of A Mechanistic Understanding Of High-Temperature Deformation Of Alloy Ep-823 For Transmutation Applications Trp Task-10: Quarterly Progress Report (March 01 – May 31, 2003), Ajit K. Roy, Brendan O'Toole May 2003

Development Of A Mechanistic Understanding Of High-Temperature Deformation Of Alloy Ep-823 For Transmutation Applications Trp Task-10: Quarterly Progress Report (March 01 – May 31, 2003), Ajit K. Roy, Brendan O'Toole

Transmutation Sciences Materials (TRP)

The purpose of this project is to evaluate the elevated temperature tensile properties of Alloy EP- 823, a leading target material for accelerator-driven waste transmutation applications. This alloy has been proven to be an excellent structural material to contain the lead-bismuth-eutectic (LBE) nuclear coolant needed for fast spectrum operations. Very little data exist in the open literature on the tensile properties of this alloy. The test material will be thermally treated prior to the evaluation of its tensile properties at temperatures relevant to the transmutation applications. The deformation characteristics of tensile specimens, upon completion of testing, will be evaluated by …


Heat Exchanger Fouling In Phosphoric Acid Evaporators - Evaluation Of Field Data -, R. M. Behbahani, H. Müller-Steinhagen, M. Jamialahmadi May 2003

Heat Exchanger Fouling In Phosphoric Acid Evaporators - Evaluation Of Field Data -, R. M. Behbahani, H. Müller-Steinhagen, M. Jamialahmadi

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Multistage evaporators are frequently used in phosphoric acid plants to increase the concentration of dilute phosphoric acid to 52-55 wt% P2O5. The concentrated phosphoric acid solution is supersaturated with respect to calcium sulfate. As a result, part of the calcium sulfate in the liquor deposits on the heat exchanger tube walls. Since the thermal conductivity of these scales is very low, thin deposits can create a significant resistance to heat transfer. Therefore, regular cleaning of heat exchangers is required, frequently at less than biweekly intervals. As the major costs in modern phosphoric acid plants are the …


Fouling During The Use Of Seawater As Coolant - The Development Of A ‘User Guide’, S. Pugh, G.F. Hewitt, H. Müller-Steinhagen May 2003

Fouling During The Use Of Seawater As Coolant - The Development Of A ‘User Guide’, S. Pugh, G.F. Hewitt, H. Müller-Steinhagen

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

ESDU International of London, UK has recently published a ‘User Guide’ on fouling in heat exchange systems using seawater as the coolant. Developed over a period of eighteen months in close collaboration with a team of oil refiners, heat transfer equipment and services suppliers and universities, with valuable input from the power industry, the User Guide is a practical guide to the current state of knowledge relating to fouling in cooling systems using seawater. Its objective is to provide the designer and the operator of both onshore and offshore equipment with a practical source of guidance on the occurrence, the …


Crystallisation Fouling Of Mixed Salts During Convective Heat Transfer And Sub-Cooled Flow Boiling Conditions, A. Helalizadeh, H. Müller-Steinhagen, M. Jamialahmadi May 2003

Crystallisation Fouling Of Mixed Salts During Convective Heat Transfer And Sub-Cooled Flow Boiling Conditions, A. Helalizadeh, H. Müller-Steinhagen, M. Jamialahmadi

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

The mechanisms of mixed salt crystallisation fouling on heat transfer surfaces have been investigated for convective and sub-cooled flow boiling heat transfer. Effects of various operating parameters such as solution composition and hydrodynamics of the system, on crystallisation fouling of mixtures of calcium sulphate and calcium carbonate have been studied experimentally. The results of the experiments were used to develop a mechanistic model for prediction of fouling resistances. Model predictions were compared with the measured experimental data when calcium sulphate and calcium carbonate form and deposit on the heat transfer surface, simultaneously. Deviations ranging from 6% to 25% were observed …


A Comparison Of The Operating Characteristics Of Two Cooling Water Systems Using Chlorine And Chlorine Dioxide Biocides, T. R. Bott, I.E. C. Mott May 2003

A Comparison Of The Operating Characteristics Of Two Cooling Water Systems Using Chlorine And Chlorine Dioxide Biocides, T. R. Bott, I.E. C. Mott

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Tests using side streams from an industrial cooling water system have been made to compare the corrosion rates associated with the use of chlorine and chlorine dioxide biocides. Two streams were employed, a "once through" and a recirculating system employing a cooling tower. The water used in the plant originated from a canal. The results of the tests revealed differences in characteristics between the circuits, depending on the biocide used and the operating conditions. The data obtained demonstrated a higher corrosion rate of 1.5 mpy with chlorine compared to 1.0 mpy using chlorine dioxide.


Deposition Of Na2Co3 In Supercritical Water Oxidation Systems And Its Mitigation, M. S. Khan, S. N. Rogak May 2003

Deposition Of Na2Co3 In Supercritical Water Oxidation Systems And Its Mitigation, M. S. Khan, S. N. Rogak

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Supercritical water oxidation is a technique to destroy wet organic waste. The oxidation reaction takes place at high temperature and pressure. Organics are miscible at these conditions but inorganic salts are not soluble and present fouling problems. Examples of these salts are sodium sulfate and sodium carbonate.

Research is being done in the University of British Columbia to study the fouling behavior of Na2CO3 in the SCWO reactor. The working fluid is heated by passing alternating current through the reactor wall. Since the tube surface was hotter than the bulk fluid, the salt was expected to nucleate …


Physical Water Treatment For The Mitigation Of Mineral Fouling In Cooling-Tower Water Applications, Young I. Cho, Sunghyuk Lee, Wontae Kim, Sangho Suh May 2003

Physical Water Treatment For The Mitigation Of Mineral Fouling In Cooling-Tower Water Applications, Young I. Cho, Sunghyuk Lee, Wontae Kim, Sangho Suh

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

The physical water treatment (PWT) device is defined as a non-chemical method of water treatment utilized for the purpose of scale prevention or mitigation. Three different PWT devices, including permanent magnets, solenoid coil device, and high-voltage electrode, were used under various operating conditions. The present study proposed a bulk precipitation as the mechanism of the PWT and conducted a number of experimental tests to evaluate the performance of the PWT. The results of fouling resistances obtained in a heat transfer test section clearly demonstrated the benefit of the PWT when the PWT device was configured at an optimum condition. The …


Analysis And Steps To Mitigate Heat Exchanger Fouling In An Aromatics Plant, Shinji Isogai , Mitsutaka Nakamura May 2003

Analysis And Steps To Mitigate Heat Exchanger Fouling In An Aromatics Plant, Shinji Isogai , Mitsutaka Nakamura

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

A heat exchanger, upstream a distillation tower for the separation of BTX (benzene, toluene, xylene) from crude benzene in an aromatics plant, experiences heavy fouling. The fouling mechanism and countermeasures to mitigate or eliminate it, were investigated. An Alcor Hot Liquid Process Simulator (HLPS)was used for the fouling rate measurement. The main mechanism is a combination of precipitation fouling and chemical reaction fouling. Effects, such as temperature, vapor ratio (vapor mole fraction of the fluid), heater materials, surface roughness and the addition of some different types of chemicals were studied. From the experiments, some countermeasures for this fouling were proposed. …


Chemical Cleaning Of Oil Refinery Heat Exchangers -- The Need For A Joint Effort, Himanshu M. Joshi, Glen Brons May 2003

Chemical Cleaning Of Oil Refinery Heat Exchangers -- The Need For A Joint Effort, Himanshu M. Joshi, Glen Brons

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

One component of the high cost of fouling to oil refineries is the maintenance money spent to clean fouled heat exchangers and the associated lost production while the exchanger is out of service. This presentation will highlight some specific fouling situations in oil refineries which can benefit from chemical cleaning. Cooperative efforts are needed between refinery operators, researchers, and chemical suppliers to develop the proper solvents and to find the optimum procedures to use them for cleaning.


Challenges In Cleaning: Recent Developments And Future Prospects, D. I. Wilson May 2003

Challenges In Cleaning: Recent Developments And Future Prospects, D. I. Wilson

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

There is considerable scope for optimisation of processes subject to fouling by effective management of cleaning. The cleaning cycle starts with the (often-complex) material generated during the fouling cycle. The nature of the deposit determines the most appropriate cleaning method, which can often be optimised significantly via knowledge of the key mechanisms involved in deposit removal. Links between deposit ageing and cleanability need to be established and quantified. There is a wide range of cleaning methods available, and attention is focused here on cleaning-in-place (CIP) techniques. Modern instrumentation allows cleaning (and deposit materials behaviour) to be probed to greater degree …


Fouling Characteristics Of A Light Australian Crude Oil, Zaid S. Saleh, R. Sheikholeslami, A. P. Watkinson May 2003

Fouling Characteristics Of A Light Australian Crude Oil, Zaid S. Saleh, R. Sheikholeslami, A. P. Watkinson

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Australian crude oils, which generally contain little asphaltenes, nevertheless give rise to fouling in refinery pre-heat trains. In this research, fouling of a series of such crude oils and their blends is being assessed. The present work focuses on thermal fouling resulting from heating Gippsland crude oil at moderate temperatures. The oil is maintained under nitrogen at a pressure of 379 kPa, and re-circulated at bulk temperatures of 80-120°C through an electrically heated annular probe at velocities in the range 0.25 to 0.65 m/s with surface temperatures from 180-260°C. Experiments are run for periods up to 90 hours at constant …


Measurement And Modeling For The Mitigation Of Organic Crystallization Fouling, Shinji Isogai, Mitsutaka Nakamura, Hirofumi Inokuchi, Hiroaki Kimura, Yoshio Koga May 2003

Measurement And Modeling For The Mitigation Of Organic Crystallization Fouling, Shinji Isogai, Mitsutaka Nakamura, Hirofumi Inokuchi, Hiroaki Kimura, Yoshio Koga

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

One of the aromatic compound plants in Mitsubishi Chemical Corporation has a heavy crystallization fouling problem. In order to solve this problem, using a low power gamma ray sensor, we found the location of heaviest fouling and measured the fouling growth rate. We also made a crystallization fouling laboratory test unit (simulator) to study the effects of some factors, such as temperature, liquid velocity, surface roughness and liquid composition. Fouling rates of the industrial plant cooler and the laboratory fouling test unit were modeled using a combination of Kern-Seaton and Reitzer models. However, the parameters of the plant and test …


The Early Stages Of Deposition Of Magnetite Particles Onto Alloy-800 Heat Exchange Surfaces Under Subcooled Boiling Conditions, Norman Arbeau, William Cook , Derek Lister May 2003

The Early Stages Of Deposition Of Magnetite Particles Onto Alloy-800 Heat Exchange Surfaces Under Subcooled Boiling Conditions, Norman Arbeau, William Cook , Derek Lister

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

The data collected during experiments in water loops on the fouling of heat exchange surfaces with magnetite particles often display a dip in the deposit accumulation curve at about 10 – 20 hours into the experiment. Generally the dips are small enough to be considered part of the scatter and may not even be discernible in long runs with considerable amounts of deposit. We have examined this phenomenon in a series of short experiments lasting up to a maximum of 40 hours. The test section of the recirculating water loop used for the study contained a heat exchanger tube of …


Identification And Testing Of Amines For Steam Generator Corrosion And Fouling Control, S. J. Klimas, K. Fruzzetti, C. W. Turner, P. V. Balakrishnan, G. L. Strati , R. L. Tapping May 2003

Identification And Testing Of Amines For Steam Generator Corrosion And Fouling Control, S. J. Klimas, K. Fruzzetti, C. W. Turner, P. V. Balakrishnan, G. L. Strati , R. L. Tapping

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

AECL and EPRI have been evaluating candidate amines for control of corrosion and fouling in recirculating nuclear steam generators. To permit an unambiguous ranking of the suitability of the candidate amines, the characteristics of base strength, volatility, price, steam generator fouling, cost of associated condensate and blowdown polishing, toxicity and ecotoxicity have been summarized in a single numerical index. The majority of the data required for the calculation of the index is available in the literature. The effect of amine on steam generator fouling has been measured using a recirculating loop at AECL under flow boiling conditions. The loop results …


Fouling Enhancement Under Flow Boiling At Elevated Steam Qualities, S. J. Klimas, J. M. Pietralik, K. Fruzzetti , R. L. Tapping May 2003

Fouling Enhancement Under Flow Boiling At Elevated Steam Qualities, S. J. Klimas, J. M. Pietralik, K. Fruzzetti , R. L. Tapping

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Under laboratory conditions of flow boiling in water at 272–285°C (5.7 to 7.0 MPa), it has been observed that fouling rates by colloidal iron oxides ("crud") dramatically increase upon reaching a certain steam quality and mixture velocity. In loop tests, an increase in fouling rates by up to 3 orders of magnitude was repeatedly observed. This effect is called here “heavy fouling under elevated steam quality” (HFESQ).

HFESQ is potentially very significant for once-through steam generators, and very large versions of recirculating nuclear steam generators, because it can lead to heavy fouling in the upper tube bundle.

The mechanism of …


The Practical Application And Innovation Of Cleaning Technology For Heat Exchangers, George E. Saxon Jr., Richard E. Putman May 2003

The Practical Application And Innovation Of Cleaning Technology For Heat Exchangers, George E. Saxon Jr., Richard E. Putman

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

The fouling of heat exchangers not only has a negative impact on heat transfer efficiency but also may restrict the output or production capacity of the facility. Given the cooling medium and the process, heat exchangers may be lightly fouled with organic deposits or may be severely blocked from hardened process chemicals. The probability of success in cleaning the heat exchanger is dependent on the selection of the appropriate cleaning technology under the specific fouling conditions. Early identification of fouling characteristics and a fundamental knowledge of cleaning system capabilities are essential in determining the most effective cleaning technology and the …


Fouling Mitigation Using Helixchanger Heat Exchangers, Bashir I. Master, Krishnan S. Chunangad, Venkateswaran Pushpanathan May 2003

Fouling Mitigation Using Helixchanger Heat Exchangers, Bashir I. Master, Krishnan S. Chunangad, Venkateswaran Pushpanathan

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

One of the major indeterminates in the design as well as operation of heat exchangers is the rate of fouling a select heat exchanger geometry would exhibit over the operation cycles. Gradual deterioration of heat exchanger performance due to the accumulation of fouling film on the heat transfer surface is often accounted for in the form of a fouling resistance, or commonly known as the fouling factor, while determining the heat transfer surface required for a specific heat duty. More often, the fouling mechanism responsible for the deterioration of heat exchanger performance is flow-velocity dependent. Maldistribution of flow, wakes and …


Overview Of Actual Methods For Characterization Of Ash Depostion, Ch. López, S. Unterberger, J. Maier, K. R. G. Hein May 2003

Overview Of Actual Methods For Characterization Of Ash Depostion, Ch. López, S. Unterberger, J. Maier, K. R. G. Hein

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Utility operation with frequent fuel switching is a common practice, forced by cheaper coal availability in the international market. Additionally, a substitution of coal by cheaper local secondary fuels, ranging from forest wood to sewage sludge and industrial or domestic residues, is gaining importance. Switching between different fuels, even if these do not differ much from the design coal, enhances operational problems arising from ash deposition. In order to prevent operational problems, through comprehension of the phenomena taking place within the furnace, appropriate sampling and characterization of the deposits are necessary. Methods commonly used for analysis of ash deposits and …


Table Of Contents, The Editors May 2003

Table Of Contents, The Editors

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

No abstract provided.


Bayer Process Heat Exchangers Cleaning Efficiency: Optimizing The Acid Dissolution Of Sodalite Scale, Sébastien Fortin , Raymond Breault May 2003

Bayer Process Heat Exchangers Cleaning Efficiency: Optimizing The Acid Dissolution Of Sodalite Scale, Sébastien Fortin , Raymond Breault

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Aluminum metal is produced by the electrolytic reduction of aluminum oxide (Al2O3), mainly extracted from bauxite ore digested in a hot caustic soda solution. This solution is supersaturated with respect to sodium aluminate and silicate, which react together to form sodalite (3[Na2O·Al2O3·2SiO2 ·2H2O] ·Na2CO3) at high temperatures. Heat exchanger tubes are scaled with this compound, which seriously reduces heat transfer coefficient, thus increasing energy costs.

Heat exchanger tubes are cleaned periodically with a sulfuric acid solution that contains a corrosion inhibitor. An investigation …


Fouling And Cleaning Of Modified Stainless Steel Plate Heat Exchangers Processing Milk Products, M. Beuf, G. Rizzo, J. C. Leuliet, H. Müller-Steinhagen, S. Yiantsios, A. Karabelas, T. Benezech May 2003

Fouling And Cleaning Of Modified Stainless Steel Plate Heat Exchangers Processing Milk Products, M. Beuf, G. Rizzo, J. C. Leuliet, H. Müller-Steinhagen, S. Yiantsios, A. Karabelas, T. Benezech

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Fouling of heat exchangers in dairy industries is still quite a severe problem both technically and economically. Altering the surface properties of the heating surfaces would be a way of solving this issue.

Modified steel surfaces were tested in an Alfa Laval V2 plate heat exchanger throughout dairy product sterilization. The behavior was analyzed for 8 different surface treatments, such as coatings (Diamond Like Carbon [DLC], Silica, SiOX, Ni-P-PTFE, Excalibur®, Xylan®) and ion implantation (SiF+, MoS2).

All fouling and cleaning experiments were carried out in standard and well-controlled operating conditions. After fouling, …


Analysis Of Fouling Data Based On Prior Knowledge, M. R. Malayeri , H. Müller-Steinhagen May 2003

Analysis Of Fouling Data Based On Prior Knowledge, M. R. Malayeri , H. Müller-Steinhagen

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Conventional regression methods are generally unable to analyse extremely complicated processes involving a considerable number of independent variables with poorly understood interaction. These methods use a defined equation for which the parameters of this equation have to be determined. It is however questionable whether any arbitrarily chosen equation is the best. This study aims to implement the powerful neural network architecture for a comprehensive data bank. The HTRI data bank contains a large and unique set of experimental data for cooling water fouling. Only a selection of the data bank is being used at the present time, due to the …


Development Of A Mechanistic Understanding Of High-Temperature Deformation Of Alloy Ep-823 For Transmutation Applications, Ajit K. Roy, Brendan O'Toole May 2003

Development Of A Mechanistic Understanding Of High-Temperature Deformation Of Alloy Ep-823 For Transmutation Applications, Ajit K. Roy, Brendan O'Toole

Transmutation Sciences Materials (TRP)

The purpose of this project is to evaluate the elevated temperature tensile properties of Alloy EP-823, a leading target material for accelerator-driven waste transmutation applications. This alloy has been proven to be an excellent structural material to contain the lead-bismuth-eutectic (LBE) nuclear coolant needed for fast spectrum operations. However, very little data exist in the open literature on the tensile properties of this alloy. The selection of Alloy EP-823 as the test material in the proposed task is based on the recommendation of our collaborator at the Los Alamos National Laboratory (LANL). The test material will be thermally treated prior …


Wright State University College Of Engineering And Computer Science Bits And Pcs Newsletter, Volume 19, Number 7, May 2003, College Of Engineering And Computer Science, Wright State University May 2003

Wright State University College Of Engineering And Computer Science Bits And Pcs Newsletter, Volume 19, Number 7, May 2003, College Of Engineering And Computer Science, Wright State University

BITs and PCs Newsletter

An eight page newsletter created by the Wright State University College of Engineering and Computer Science that addresses the current affairs of the college.