The Effects Of Corrosive Chemicals On Corrosion Rate Of Steel Reinforcement Bars: I. Swamp Water, Sulistyoweni Widanarko, Henki W. Ashadi, Andri Krisnadi Wicaksono Aug 2002

The Effects Of Corrosive Chemicals On Corrosion Rate Of Steel Reinforcement Bars: I. Swamp Water, Sulistyoweni Widanarko, Henki W. Ashadi, Andri Krisnadi Wicaksono

Makara Journal of Technology

Most of infrastructures using steel concrete to reinforce the strength of concrete. Steel concrete is so vulnerable to chemical compounds that can cause corrosion. It can happen due to the presence of chemical compounds in acid environment in low pH level. These chemical compounds are SO4 2-, Cl-, NO3 -. There are many swamp area in Indonesia. The acid contents and the concentration of ion sulphate, chlorides, and nitrate are higher in the swamp water than in the ground water .The objective of this research was to find out the influence of corrosive chemicals in the swamp water to the …


The Effects Of Corrosive Chemicals On Corrosion Rate Of Steel Reinforcement Bars: Ii. Swamp Sludges, Henki W. Ashadi, Sulistyoweni Widanarko, Irma Gusniani Aug 2002

The Effects Of Corrosive Chemicals On Corrosion Rate Of Steel Reinforcement Bars: Ii. Swamp Sludges, Henki W. Ashadi, Sulistyoweni Widanarko, Irma Gusniani

Makara Journal of Technology

A polluted environment will influence the building age. The objective of this research was to find out the influence of corrosive chemicals within the sludge swamp area with the corrosion rate of steel concrete. Corrosion in steel concrete usually occur in acid area which contain of SO4 2-, Cl- and NO3 -. The research treatment used by emerging ST 37 and ST 60 within 60 days in ‘polluted’ sludge swamp area. Three variation of ‘polluted’ swamp sludge were made by increasing the concentration a corrosive unsure up to 1X, 5X and 10X. The corrosion rate measured by using an Immersion …


Shear Strength Of R/C Beams Wrapped With Cfrp Fabric, P. Alagusundaramoorthy, Issam E. Harik, Ching Chiaw Choo Aug 2002

Shear Strength Of R/C Beams Wrapped With Cfrp Fabric, P. Alagusundaramoorthy, Issam E. Harik, Ching Chiaw Choo

Kentucky Transportation Center Research Report

The emergence of high strength epoxies has enhanced the feasibility of increasing the shear strength of concrete beams by wrapping with carbon fiber reinforced polymer (CFRP) fabric. The objective of this investigation is to evaluate the increase in shear strength of concrete beams wrapped with different configurations of CFRP fabric. Shear tests are conducted up to failure on two reinforced concrete control beams and twelve reinforced concrete beams wrapped with four different configurations of CFRP fabric. An analytical procedure is presented to predict the shear strength of beams wrapped with CFRP fabric. Comparisons are made between the test results and …


Flexural Behavior Of R/C Beams Strengthened With Cfrp Sheets Or Fabric, P. Alagusundaramoorthy, Issam E. Harik, Ching Chiaw Choo Aug 2002

Flexural Behavior Of R/C Beams Strengthened With Cfrp Sheets Or Fabric, P. Alagusundaramoorthy, Issam E. Harik, Ching Chiaw Choo

Kentucky Transportation Center Research Report

The resistance to electro-chemical corrosion, high-strength to weight ratio, larger creep strain, fatigue resistance, non-magnetic and non-metallic properties of carbon fiber reinforced polymer (CFRP) composites offer a viable alternative to bonding of steel plates in repair and rehabilitation of reinforced concrete structures. The objective of this investigation is to study the effectiveness of externally bonded CFRP sheets or fabric in increasing the flexural strength of concrete beams. Four-point bending flexural tests are conducted up to failure on nine concrete beams strengthened with different layouts of CFRP sheets and fabric, and three beams with different layouts of anchored CFRP sheets. An …


Evaluation And Carbon Fiber Reinforced Polymer Strengthening Of Existing Garage: Case Study, Milan Vatovec, Paul L. Kelley, Tarek Alkhrdaji, Antonio Nanni Aug 2002

Evaluation And Carbon Fiber Reinforced Polymer Strengthening Of Existing Garage: Case Study, Milan Vatovec, Paul L. Kelley, Tarek Alkhrdaji, Antonio Nanni

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The concrete-repair fiber reinforced polymer technology emerged in the United States during the past 10 years. Since 1995, carbon fiber reinforced polymer (CFRP) has been applied to strengthen concrete decks of a troubled posttensioned garage in Atlanta. During the construction of the garage, design deficiencies were found. A remedial repair, involving heavily reinforced, 7.6 cm (3 in.) thick Gunite (Shotcrete) beams, applied to the underside of the slab between drop panels in the east-west (E-W) direction, was developed in 1984. Since then, delamination of Gunite beams and other structural problems repeatedly occurred. Epoxy injection and other limited repairs were done …


Bs News Aug 2002

Bs News

Building Services Engineering

No abstract provided.


Effects Of Carbonation On Mechanical Properties And Durability Of Concrete Using Accelerated Testing Method, Jack M. Chi, Ran Huang, C. C. Yang Jun 2002

Effects Of Carbonation On Mechanical Properties And Durability Of Concrete Using Accelerated Testing Method, Jack M. Chi, Ran Huang, C. C. Yang

Journal of Marine Science and Technology–Taiwan

An experimental investigation was carried out to study the effect of carbonation on mechanical properties and durability of concrete. Ordinary portland concretes (OPC) with water/cement ratios of 0.58 and 0.48 and self-compacting concretes (SCC) with water/binder ratios of 0.40 and 0.36 were used in this study. Compressive strength test, splitting strength test, electrical resistivity test, rapid chloride penetration test (RCPT), open circuit potential method and alternative current (AC) impedance method were performed to estimate the properties of concrete. Test results showed that carbonation may compensate some concrete properties such as compressive strength, splitting strength, electrical resistivity and chloride ion penetration. …


Bs News Jun 2002

Bs News

Building Services Engineering

No abstract provided.


Standard For Cold-Formed Steel Framing -- General Provisions, American Iron And Steel Institute May 2002

Standard For Cold-Formed Steel Framing -- General Provisions, American Iron And Steel Institute

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

The material contained herein has been developed by the American Iron and Steel Institute Committee on Framing Standards. The Committee has made a diligent effort to present accurate, reliable, and useful information on cold-formed steel framing design and installation. The Committee acknowledges and is grateful for the contributions of the numerous researchers, engineers, and others who have contributed to the body of knowledge on the subject. Specific references are included in the General Provisions document. With anticipated improvements in understanding of the behavior of cold-formed steel framing and the continuing development of new technology, this material may eventually become dated. …


Standard For Cold-Formed Steel - General Provisions, American Iron And Steel Institute May 2002

Standard For Cold-Formed Steel - General Provisions, American Iron And Steel Institute

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

The material contained herein has been developed by the American Iron and Steel Institute Committee on Framing Standards. The Committee has made a diligent effort to present accurate, reliable, and useful information on cold-formed steel framing design and installation. The Committee acknowledges and is grateful for the contributions of the numerous researchers, engineers, and others who have contributed to the body of knowledge on the subject. Specific references are included in the General Provisions document.

With anticipated improvements in understanding of the behavior of cold-formed steel framing and the continuing development of new technology, this material may eventually become dated. …


Standard For Cold-Formed Steel Framing Truss Design, American Iron And Steel Institute May 2002

Standard For Cold-Formed Steel Framing Truss Design, American Iron And Steel Institute

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

The material contained herein has been developed by the American Iron and Steel Institute Committee on Framing Standards. The Committee has made a diligent effort to present accurate, reliable, and useful information on cold-formed steel framing design and installation. The Committee acknowledges and is grateful for the contributions of the numerous researchers, engineers, and others who have contributed to the body of knowledge on the subject. Specific references are included in the Truss Standard document.

With anticipated improvements in understanding of the behavior of cold-formed steel framing and the continuing development of new technology, this material may eventually become dated. …


A Novel Membrane Process For Autotrophic Denitrification, Agnieszka Pierkiel Apr 2002

A Novel Membrane Process For Autotrophic Denitrification, Agnieszka Pierkiel

Theses and Dissertations

This research focused on the novel use of hollow fiber membranes for gas delivery in biological dentrification using hydrogen-oxidizing bacteria. Autotrophic denitrification is a biological process that reduces nitrate to nitrogen gas using an inorganic carbon source. Hydrogen gas is an electron donor and nitrate is the electron acceptor in the reaction. The specific research objectives were to:

  • develop a mixed acclimated culture of hydrogen-oxidizing bacteria;
  • evaluate biodegradation kinetics of the acclimated culture;
  • evaluate hydrogen transfer characteristics of hollow fiber membrane modules;

and

  • demonstrate technical feasibility of a continuous bioreactor-membrane system for denitrification.

The following kinetic coefficients were obtained: µ …


Bs News Apr 2002

Bs News

Building Services Engineering

No abstract provided.


Hexavalent Chromium Dissociation From Overspray Particles Into Fluid For Three Aircraft Primers, Richard A. Schilke Mar 2002

Hexavalent Chromium Dissociation From Overspray Particles Into Fluid For Three Aircraft Primers, Richard A. Schilke

Theses and Dissertations

DOD and industry use chromate-containing primers extensively to inhibit corrosion on metal assets. Chromate contains Cr6+, a human carcinogen, but there is little epidemiological evidence of increased lung cancer among spray painters. Using bio-aerosol impingers, overspray particles from three primers (solvent-borne epoxy, water-borne epoxy, and solvent-borne polyurethane) were collected into water to test the hypothesis that the paint matrix inhibits Cr6+ release into water, under the premise that this simulates Cr6+ release from particles into lung fluid. Particles were allowed to reside in water for 1 or 24 hours, then separated from the water by centrifugation, …


Comparative Energy And Cost Analysis Between Conventional Hvac Systems And Geothermal Heat Pump Systems, David D. Vanderburg Mar 2002

Comparative Energy And Cost Analysis Between Conventional Hvac Systems And Geothermal Heat Pump Systems, David D. Vanderburg

Theses and Dissertations

To sustain the United States current affluence and strength, the U.S. Government has encouraged energy conservation through executive orders, federal and local laws, and consumer education. A substantial reduction in U.S. energy consumption could be realized by using geothermal heat pumps to heat and cool buildings throughout the U.S., though initial installation cost are a deterrent. This thesis uses Monte Carlo simulation to predict energy consumption, life cycle cost and payback period for the vertical closed-loop ground source heat pump (GSHP) relative to conventional heating ventilation and air conditioning (HVAC) systems: air-source heat pumps (ASHP), air-cooled air conditioning with either …


Bs News Mar 2002

Bs News

Building Services Engineering

No abstract provided.


Experimental Maintenance Painting On Various Bridge Projects: Kentucky Highway Investigative Task 40, Theodore Hopwood Ii, Sudhir Palle, Rick Younce Feb 2002

Experimental Maintenance Painting On Various Bridge Projects: Kentucky Highway Investigative Task 40, Theodore Hopwood Ii, Sudhir Palle, Rick Younce

Kentucky Transportation Center Research Report

The Kentucky Transportation Center (KTC) at the University of Kentucky has performed a series of research studies for the Kentucky Transportation Cabinet (KYTC) to monitor various experimental bridge painting projects and conduct investigative work focusing on new paint systems. The research study addressed in this report “Experimental Maintenance Painting On Various Bridge Projects During 1998-2000” Kentucky Highways Investigative Task No: 40 was intended to address experimental projects in fiscal years 1999 and 2000, but was extended to address certain fieldwork and KYTC inspections through December 31, 2000.

KTC/KYTC Paint Team joint efforts in late 1998 into early 1999 centered on …


Studies On Use Of Carbon Slurry, A Waste From Fertilizer Plant, In Treatment Of Waste Water, Sanjay Tewari Feb 2002

Studies On Use Of Carbon Slurry, A Waste From Fertilizer Plant, In Treatment Of Waste Water, Sanjay Tewari

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

"Non biodegradable materials like heavy metals, refractory organics are not removed during the conventional treatment process. In order to meet the regulatory standards and for safe disposal, it is necessary to go for tertiary treatment. Various tertiary treatment methods include adsorption, membrane separation process, ultra filtration, reverse osmosis etc. Adsorption has been found to be efficient for the removal of most of heavy metals in waste water at lower concentrations. Activated carbon is commonly used adsorbents, however, due to its high cost and loss in regeneration, various low cost adsorbents have been investigated during recent years.

The aim of the …


Bs News Feb 2002

Bs News

Building Services Engineering

No abstract provided.


Underwater Concrete, Dina Adel Nakhla Feb 2002

Underwater Concrete, Dina Adel Nakhla

Archived Theses and Dissertations

Underwater structures represent a significant portion of concrete works worldwide. The utilization of various underwater concrete techniques has indeed minimized the use of costly dewatering processes. Such techniques include the use of special· equipment such as trernie concrete and preplaced aggregate technique. The incorporation of antiwashout admixtures has evolved as a method to minimize the washout of cement and fine particles. As for today, there exists relatively limited information regarding different underwater concreting techniques to facilitate feasible and adequate selection of appropriate methods. This work comprises a survey study and an experimental work to evaluate the impact of using the …


Mechanical Properties And Stress-Strain Behavior Of High Performance Concrete Under Uniaxial Compression, Pornchai Jiratatprasot Jan 2002

Mechanical Properties And Stress-Strain Behavior Of High Performance Concrete Under Uniaxial Compression, Pornchai Jiratatprasot

Theses

Many recent innovations in advanced concrete materials technology have made it possible to produce concrete with exceptional performance characteristics. High performance concrete (HPQ is defined as concrete that meets special performance and uniformity requirements that cannot always be achieved routinely by using conventional materials and normal mixing, placing, and curing practices. The importance of HPC to structural engineering is unquestionable. However, HPC is a relatively new material. Some results of research on conventional concrete are not entirely applicable. In this experiment, the main mechanical properties of HPC including compressive strength, modulus of elasticity, and Poisson's ratio were investigated and compared …


Shear Behavior Of Reinforced Concrete Deep Beams Strengthened With Cfrp Laminates, Jon Erik Moren Jan 2002

Shear Behavior Of Reinforced Concrete Deep Beams Strengthened With Cfrp Laminates, Jon Erik Moren

Theses

Considerable research has been performed using CFRP plates bonded to normal reinforced concrete beams, the objective being to improve shear and flexural strength. However, very few tests have been performed on reinforced concrete deep beams with CFRP as shear reinforcement. The purpose of this experiment is to investigate the behavior of the deep beam in shear with various arrangements of Sika CarboDur laminates bonded to the sides. The beams were designed to be shear deficient with stirrups omitted, except at the supports and directly under the load. In total eight beams were tested, four with one-point loading and four with …


Biological Fixed Film Systems, Mark W. Fitch, Ellen England Jan 2002

Biological Fixed Film Systems, Mark W. Fitch, Ellen England

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

No abstract provided.


The Interaction Between Hydrology And Water Quality For Urban Rainfall-Runoff: Implications For Management Strategies, Christopher Michael Dean Jan 2002

The Interaction Between Hydrology And Water Quality For Urban Rainfall-Runoff: Implications For Management Strategies, Christopher Michael Dean

LSU Master's Theses

In urban environments, anthropogenic activity deposits potentially hazardous residuals onto impervious surfaces. To investigate the process of wet-weather constituent transport, twelve rainfall/runoff events collected at an experimental catchment site in Baton Rouge, Louisiana were analyzed for temporal delivery of aggregate constituents (SSC, COD, TDS) as well as dissolved and particulate-bound metal concentrations (Cd, Cu, Pb and Zn). Event mean concentrations for the parameters analyzed often exceeded USEPA discharge limits. Rainfall-runoff events were characterized as either mass-limited or flow-limited. Events designated as mass-limited exhibited a high runoff volume, low vehicle to volume ratio (VPV), high stream power and a low correlation …


Tension Lap Splice Lengths Of Carbon Fiber Reinforced Polymer Bars, Gregory Patrick Sepeda Jan 2002

Tension Lap Splice Lengths Of Carbon Fiber Reinforced Polymer Bars, Gregory Patrick Sepeda

LSU Master's Theses

With recent advances in the area of fiber reinforced polymers (FRP), more effort has been spent trying to incorporate the use of FRP in design applications. FRP bars offer both an ultimate strength and a corrosion resistance greater than traditional steel reinforcing. Fiber reinforced polymer bars can either consist of continuous glass (GFRP), aramid (AFRP) or carbon fibers (CFRP). CFRP bars, while lighter than GFRP typically offer a much greater tensile strength. With the recent release of the American Concrete Institute’s first edition manual ACI-440.1R “Guide for the Design and Construction of Concrete Reinforced with FRP Bars” (2001), unified design …


Fatigue Behavior Of Beam Diaphragm Connections With Intermittent Fillet Welds: Part Ii, Brittle Fracture Examination Of The I-64 Blue River Bridge, Mark D. Bowman Jan 2002

Fatigue Behavior Of Beam Diaphragm Connections With Intermittent Fillet Welds: Part Ii, Brittle Fracture Examination Of The I-64 Blue River Bridge, Mark D. Bowman

JTRP Technical Reports

This report is the second of a two-part, three volume final report presenting the findings of the research work that was undertaken to evaluate the behavior of Indiana highway bridges with diaphragm members welded directly to the web of the primary beams and girders. Fatigue cracks have been observed at several bridges that utilize the welded diaphragm connection. The seriousness of the cracking and the corresponding potential risk on the integrity of the bridge superstructure were assessed. Inspection and repair guidelines for bridges with the welded diaphragm connections were also developed as part of the research effort. This volume presents …


Guidelines For Use And Types Of Retaining Devices, Antonio Bobet Jan 2002

Guidelines For Use And Types Of Retaining Devices, Antonio Bobet

JTRP Technical Reports

A large number of types of retaining devices are currently available but their limitations, recommendations and guidelines are scattered in the technical literature. A synthesis study has been made in which different technologies have been investigated to develop guidelines for the use of the different types of retaining devices. For this purpose, an extensive literature review has been performed and a new classification has been proposed. An electronic database with 207 selected cases from the technical literature and INDOT archives has been created. The database stores the following information: (1) Type of Retaining Device; (2) Geometry (3) Soil conditions; (4) …


Performance-Related Specifications For Concrete Bridge Superstructures, Volume 1: Performance Parameters And Related Procedure For Concrete Bridge Superstructures, J. A. Ramirez, Jhon Paul Smith Jan 2002

Performance-Related Specifications For Concrete Bridge Superstructures, Volume 1: Performance Parameters And Related Procedure For Concrete Bridge Superstructures, J. A. Ramirez, Jhon Paul Smith

JTRP Technical Reports

In Volume 1 of the final report, the identification of performance levels and parameters, and the development of acceptance criteria, have been addressed. Emphasis has been placed on the development of a methodology for a Performance Related Specification, PRS, for concrete bridge superstructures. The implementation of the methodology, presented in the form of a user-friendly computer program, is project specific. It requires the mean and standard deviation (or definition of a probability distribution) of the input parameters for the performance predictive models. This is done for both the as-designed condition and the as-built condition of the structure. The contractor is …


Performance-Related Specifications For Concrete Bridge Superstructures, Volume 4: Bond Of Epoxy-Coated Bars With Thicker Coatings, J. A. Ramirez, Michael K. Appelhans Jan 2002

Performance-Related Specifications For Concrete Bridge Superstructures, Volume 4: Bond Of Epoxy-Coated Bars With Thicker Coatings, J. A. Ramirez, Michael K. Appelhans

JTRP Technical Reports

In Volume 4 of the final report, the results of an evaluation of the bond performance of epoxy-coated bars with a coating thickness up to 18 mils are presented. The experimental work on the bond performance of epoxy-coated bars with thickness up to 18 mils indicates that the current AASHTO requirements for development length of epoxy-coated bars up to #8 could be safely extended to coating thickness of up to 18 mils. Thus, no change to the bond specifications is recommended in order to implement the use of bars with diameters up to a #8 with epoxy-coating thickness up to …


Performance-Related Specifications For Concrete Bridge Superstructures, Volume 2: High-Performance Concrete, J. Olek, Aijsing Lu, Xiuping Feng, Bryan Magee Jan 2002

Performance-Related Specifications For Concrete Bridge Superstructures, Volume 2: High-Performance Concrete, J. Olek, Aijsing Lu, Xiuping Feng, Bryan Magee

JTRP Technical Reports

This is Volume 2 of the Final Report for the project titled “Performance-Related Specifications for Concrete-Bridge Superstructures” dealing with the topic of High-Performance Concrete (HPC). The investigation of high-performance concrete included the development of optimized concrete mixtures and identifying their performance characteristics related to durability for the purpose of using these characteristics in performance–related specifications in the state of Indiana. The research effort described in this report was divided in two phases. Phase I was focused on development of concrete mixtures optimized with respect to selected performance-related parameters. During this phase, ten optimum concrete mixes have been identified from 45 …