Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Civil and Environmental Engineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 2641 - 2670 of 3988

Full-Text Articles in Entire DC Network

Design, Construction And Load Testing Of The Bridge On Arnault Branch, Washington County, Missouri Using Innovative Technologies, Dongming Yan, Genda Chen, Nestore Galati, Sahra Sedigh Feb 2010

Design, Construction And Load Testing Of The Bridge On Arnault Branch, Washington County, Missouri Using Innovative Technologies, Dongming Yan, Genda Chen, Nestore Galati, Sahra Sedigh

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The superstructure and instrumentation designs of a three-span bridge are presented in this report. The three spans include a precast box-girder bridge, a precast deck on steel girder and a precast deck on concrete girder. They were designed to compare the performance of various bridge decks reinforced with fiber reinforced polymers (FRP) through field instrumentations. A wireless monitoring system was designed to facilitate the collection of field data after the completion of bridge construction. The collected data will allow the study of FRP bars and stay-in-place FRP grid systems.


Second Generation Precast Deck Panel (Nudeck) System, Maher K. Tadros Ph.D., P.E., Kromel E Hanna, George Morcous Ph.D. Jan 2010

Second Generation Precast Deck Panel (Nudeck) System, Maher K. Tadros Ph.D., P.E., Kromel E Hanna, George Morcous Ph.D.

Mid-America Transportation Center: Final Reports and Technical Briefs

The majority of today’s bridge decks are built using cast-in-place concrete construction. This is due to the perceived low initial cost and constructor familiarity with the system. This research report describes the design, details, and construction of an innovative full-depth precast concrete bridge deck system – the Second Generation NUDECK (Nebraska University Deck). The quality of this system is far superior to castin- place construction. Cast-in-place concrete bridge decks experience cracking shortly after construction due to differential creep and shrinkage with the supporting beams. This leads to bridge deck deterioration; a problem that is not experienced with the virtually crack-free …


Direct Detection Of Localized Modulation Of On Concentration On An Electrode-Electrolyte Interface, Ravi Saraf, Gaurav Singh Jan 2010

Direct Detection Of Localized Modulation Of On Concentration On An Electrode-Electrolyte Interface, Ravi Saraf, Gaurav Singh

Mid-America Transportation Center: Final Reports and Technical Briefs

The present invention directly measures localized electrochemical processes on a planar electrode using differential interferometry. The ionic charge accumulation at the electrode-electrolyte interface may be directly measured by using differential interferometry as a function of magnitude and frequency (for example, 2-50 kHz) of an external potential applied on an electrode. Methods in accordance with the present invention probe the ion dynamics confined to the electrical double layer. An electric field is applied using a pure AC potential and a superposition of AC and DC-ramp potential to measure ion concentration and detect redox processes.


Load Rating Of Complex Bridges, George Morcous Ph.D., Kromel Hanna Ph.D., Maher K. Tadros Ph.D., P.E. Jan 2010

Load Rating Of Complex Bridges, George Morcous Ph.D., Kromel Hanna Ph.D., Maher K. Tadros Ph.D., P.E.

Mid-America Transportation Center: Final Reports and Technical Briefs

The National Bridge Inspection Standards require highway departments to inspect, evaluate, and determine load ratings for structures defined as bridges located on all public roads. Load rating of bridges is performed to determine the live load that structures can safely carry at a given structural condition. Bridges are rated for three types of loads, design loads, legal loads, and permit loads, which is a laborious and time-consuming task as it requires the analysis of the structure under different load patterns. Several tools are currently available to assist bridge engineers to perform bridge rating in a consistent and timely manner. However, …


On The Use Of Polyurethane Matrix Carbon Fiber Composites For Strengthening Concrete Structures, Zachary Haber Jan 2010

On The Use Of Polyurethane Matrix Carbon Fiber Composites For Strengthening Concrete Structures, Zachary Haber

Electronic Theses and Dissertations

Fiber-reinforced polymer (FRP) composite materials have effectively been used in numerous reinforced concrete civil infrastructure strengthening projects. Although a significant body of knowledge has been established for epoxy matrix carbon FRPs and epoxy adhesives, there is still a need to investigate other matrices and adhesive types. One such matrix/adhesive type yet to be heavily researched for infrastructure application is polyurethane. This thesis investigates use of polyurethane matrix carbon fiber composites for strengthening reinforced concrete civil infrastructure. Investigations on mirco- and macro-mechanical composite performance, strengthened member flexural performance, and bond durability under environmental conditioning will be presented. Results indicate that polyurethane …


Influence Of Shear Key Performance On The Fatigue Life Of Adjacent Beam Bridges, Sara Roberts Jan 2010

Influence Of Shear Key Performance On The Fatigue Life Of Adjacent Beam Bridges, Sara Roberts

All Theses

Adjacent beam bridges, such as box beams and hollow core bridges have been one of the most popular forms of precast prestressed bridges in the past. Recently, an awareness of major durability problems has led owners to make improvements to the old standards or move away from the system completely. These issues usually stem from the breakdown of the shear key which provides continuity between adjacent members. This research focuses on determining the best improvements that will reduce durability issues and increase the bridge's service life.
A review of previous research performed on adjacent beam bridges is performed, focusing on …


Integrated, Multi-Attribute Decision Support System For The Evaluation Of Underground Utility Construction Methods, John C. Matthews Jan 2010

Integrated, Multi-Attribute Decision Support System For The Evaluation Of Underground Utility Construction Methods, John C. Matthews

Doctoral Dissertations

The dissertation research work described herein is comprised of three primary objectives: (1) the development of a rehabilitation method selection software (TAG-R) for the National Association of Sewer Service Companies (NASSCO) and its subsequent validation and combination with TAG (a sister decision support system (DSS) software developed by the author in an earlier work); (2) the development of a social cost calculator (SCC) and its validation; and (3) the development of a proposed framework for multi-segment optimization for construction methods selection using the tools developed in the first two objectives as well as additional project related data.

The selection of …


Probabilistic Analysis Of Concrete Fracture, Mustafa Abushaala Aldalinsi Jan 2010

Probabilistic Analysis Of Concrete Fracture, Mustafa Abushaala Aldalinsi

Open Access Theses & Dissertations

It is well known to civil engineers that fatigue leads to the bulk of structural failures. In plain and reinforced concrete structures, fatigue might account for excessive deformation, excessive of crack widths, de-bonding of reinforcement and rupture of the reinforcement, all of these can lead to structural collapse. Fatigue crack propagation can be a method to predict a remaining life of a structures. Herein will show some works that have been done in order to analyze the fatigue crack growth for plain concrete specimen. The goals of this study are to estimate the critical crack length and remaining life of …


Peer Review Report 2010 Jan 2010

Peer Review Report 2010

United States Department of Transportation: Publications

The purpose of this document is to report findings from the research peer reviews held April 14, April 15, April 27 & April 28, 2010 for PHMSA’s Pipeline Safety Research and Development Program. The findings and recommendations in this report are derived from the scoring and comments collected from the peer review panelists.

Department of Transportation (DOT) Operating Agencies (OA) are required to develop and execute a systematic process for peer reviews and for all influential and highly influential information that the OA plans to disseminate in the foreseeable future.

Through the Information Quality Act, Congress directed the Office of …


The Placement Of Remediation Amendments Into Contaminated Sediments Via Waterjet Technologies, Gavin Hunter Ray Risley Jan 2010

The Placement Of Remediation Amendments Into Contaminated Sediments Via Waterjet Technologies, Gavin Hunter Ray Risley

Masters Theses

"The use of amendments to perform in situ remediation of contaminated sediments is a technique that is relatively mature. The need exists to develop a method of amendment delivery that will efficiently place the amendments into the contaminated zone at depth with minimal impacts to the benthic communities and contaminant resuspension. Waterjets have been used for hundreds of years as an excavation, cutting, and cleaning tool, but they can also be used to inject remediation amendments into contaminated sediments if setup properly. In order to test this concept, a waterjet amendment injection system and nozzle have been developed and tested. …


Corrosion Resistance Of Enamel-Coated Steel Reinforcement For Concrete, Charles Robert Werner Jan 2010

Corrosion Resistance Of Enamel-Coated Steel Reinforcement For Concrete, Charles Robert Werner

Masters Theses

"Originally developed to enhance the bond between concrete and steel, reactive enamel coatings have shown great promise in protecting steel from corrosive environments. However, the corrosion resistance of the material has not yet been tested beyond 40 days. Moreover, when the material was tested, it was applied to smooth steel pins, not deformed steel bars which are commonly used in reinforced concrete structures. Therefore, this study focused on the corrosion resistance of three different enamel coatings, along with a standard epoxy coating, each of which were applied to both smooth and deformed steel bars and included both short-term and long-term …


Innovative Concrete Bridging Systems For Pedestrian Bridges: Implementation And Monitoring, Kurt Edward Bloch Jan 2010

Innovative Concrete Bridging Systems For Pedestrian Bridges: Implementation And Monitoring, Kurt Edward Bloch

Masters Theses

"Two precast, prestressed pedestrian bridges were designed for rapid construction in Rolla, MO, utilizing high-strength concrete (HSC) and high-strength self-consolidating concrete (HS-SCC) with a target 28 day compressive strength of 68.9 MPa (10,000 psi) and release compressive strength of 24.1 MPa (3,500 psi). In addition, a glass fiber reinforced polymer (GFRP) bar reinforced deck panel system was utilized in one of the two deck panels on each bridge.

Material properties were tested for compression, elastic modulus, modulus of rupture, splitting tensile strength, creep, and shrinkage following ASTM standards. Instrumentation systems within the spandrel beams and precast deck panels were implemented …


Transfer And Development Length Of Strands In Post-Tensioned Members After Anchor Head Failure, Elie El Zghayar Jan 2010

Transfer And Development Length Of Strands In Post-Tensioned Members After Anchor Head Failure, Elie El Zghayar

Electronic Theses and Dissertations

Post-tensioning tendons in segmental bridge construction are often only anchored within the deviator and pier segments. The effectiveness of the post-tensioning (PT) system is therefore dependent on proper functioning of the anchorages. On August 28, 2000 a routine inspection of the Mid-Bay Bridge (Okaloosa County, Florida) revealed corrosion in numerous PT tendons. Moreover, one of the 19-strand tendons was completely slacked, with later inspection revealing a corrosion-induced failure at the pier anchor location. Anchorage failure caused all PT force to transfer to the steel duct located within the pier segment that in turn slipped and caused the tendon to go …


Evaluation Of Oxidized Media Filtration Processes For The Treatment Of Hydrogen Sulfide In Groundwater, Vito Trupiano Jan 2010

Evaluation Of Oxidized Media Filtration Processes For The Treatment Of Hydrogen Sulfide In Groundwater, Vito Trupiano

Electronic Theses and Dissertations

This study evaluated alternative sulfide treatment processes for potable water systems that rely on groundwater supplies. Research for this study was conducted at the Imperial Lakes (IL) and Turner Road (TR) water treatment plants (WTPs) in Polk County, Florida. These WTPs are in the process of refurbishment and expansion, and will require the installation of a new groundwater well. The IL and TR WTPs both rely upon groundwater sources that contain total sulfide at concentrations ranging from 1.4 to 2.6 mg/L. Sulfide is a concern because if left untreated it can impact finished water quality, corrosivity, create undesirable taste and …


Feasibility Study Of Lightweight High-Strength Hollow Core Balsa-Frp Composite Beams Under Flexure, Kevin O'Neill Jan 2010

Feasibility Study Of Lightweight High-Strength Hollow Core Balsa-Frp Composite Beams Under Flexure, Kevin O'Neill

Electronic Theses and Dissertations

The United States of America's Military, more specifically the Army, has since the late 1990's had a vested interest in the development of super-lightweight, portable, short-span composite bridge and decking components to replace aging heavy metal-alloy machine driven modular systems. The following study looks at the feasibility of using balsa wood as the structural core material in fiber reinforced polymer (FRP) wrapped hollow-core composites in short-span bridge applications. The balsa provides shear resistance and the FRP the flexural resistance, resulting in extremely high strength-to-weight and strength-to-depth ratios. Several scaled short span specimens were constructed and tested using a variety of …


Analysis Of The Florida's Showcase Green Envirohome Water/Wastewater Systems And Development Of A Cost-Benefit Green Roof Optimization Model, Brian Rivera Jan 2010

Analysis Of The Florida's Showcase Green Envirohome Water/Wastewater Systems And Development Of A Cost-Benefit Green Roof Optimization Model, Brian Rivera

Electronic Theses and Dissertations

The Florida Showcase Green Envirohome (FSGE) incorporates many green technologies. FSGE is built to meet or exceed 12 green building guidelines and obtain 8 green building certificates. The two-story 3292 ft2 home is a "Near Zero-Loss Home", "Near Zero-Energy Home", "Near Zero-Runoff Home", and "Near Zero-Maintenance Home". It is spawned from the consumer-driven necessity to build a home resistant to hurricanes, tornadoes, floods, fire, mold, termites, impacts, and even earthquakes given up to 500% increase in insurance premiums in natural disaster zones, the dwindling flexibility and coverage of insurance policies, and rising energy, water and maintenance costs (FSGE 2008). The …


Casing Pipe Damage Detection With Optical Fiber Sensors: A Case Study In Oil Well Constructions, Zhi Zhou, Jianping He, Minghua Huang, Jun He, Genda Chen Jan 2010

Casing Pipe Damage Detection With Optical Fiber Sensors: A Case Study In Oil Well Constructions, Zhi Zhou, Jianping He, Minghua Huang, Jun He, Genda Chen

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Casing pipes in oil well constructions may suddenly buckle inward as their inside and outside hydrostatic pressure difference increases. For the safety of construction workers and the steady development of oil industries, it is critically important to measure the stress state of a casing pipe. This study develops a rugged, real-time monitoring, and warning system that combines the distributed Brillouin Scattering Time Domain Reflectometry (BOTDR) and the discrete fiber Bragg grating (FBG) measurement. The BOTDR optical fiber sensors were embedded with no optical fiber splice joints in a fiber-reinforced polymer (FRP) rebar and the FBG sensors were wrapped in epoxy …


Crack Detectability And Durability Of Coaxial Cable Sensors In Reinforced Concrete Bridge Applications, Genda Chen, Ryan D. Mcdaniel, Michael A. Brower, David Pommerenke Jan 2010

Crack Detectability And Durability Of Coaxial Cable Sensors In Reinforced Concrete Bridge Applications, Genda Chen, Ryan D. Mcdaniel, Michael A. Brower, David Pommerenke

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The working mechanism and the measurement principle of topology-based crack sensors made of coaxial cables are briefly reviewed. The sensitivity, spatial resolution, and ruggedness of two coaxial cable sensors, respectively made of rubber and Teflon dielectric materials, were compared and validated with laboratory testing of a 4/5-scale, T-shaped, reinforced concrete beam-column specimen. Two Teflon sensors were installed on one of the solid decks of a three-span continuous highway bridge to investigate their durability and measurement repeatability. Laboratory tests indicated that both types of sensors have high sensitivity, but the Teflon sensor has a higher spatial resolution and a negligible spillover …


Developments In Monitoring Techniques For Durability Assessment Of Cover-Zone Concrete, W.J. Mccarter, T. M. Chrisp, G. Starrs, Niall Holmes, L. Basheer, M. Basheer, S. V. Nanukuttan Jan 2010

Developments In Monitoring Techniques For Durability Assessment Of Cover-Zone Concrete, W.J. Mccarter, T. M. Chrisp, G. Starrs, Niall Holmes, L. Basheer, M. Basheer, S. V. Nanukuttan

Conference papers

This paper outlines developments in the use of an embedded multi-electrode sensor to study the response of the cover-zone (surface 50mm) to the changing ambient environment. The sensor enables the measurement of the spatial and temporal distribution of the electrical properties of concrete and temperature within the cover-zone thereby allowing an integrated assessment of cover-zone concrete performance. Both laboratory and field results are presented to highlight the information that can be obtained from embedded sensors. When exposed to the natural environment, the temperature dependence of the electrical response is highlighted and standardization protocols are developed to account for this effect. …


The Use Of Novel Non-Destructive Methods For Quality Control And Performance Evaluation Of Concrete Structures, Sree Nanukuttan, Niall Holmes, Sudarsan Srininvasan, Lulu Basheer, Muhammed Basheer, John Mccarter, Gerry Starrs Jan 2010

The Use Of Novel Non-Destructive Methods For Quality Control And Performance Evaluation Of Concrete Structures, Sree Nanukuttan, Niall Holmes, Sudarsan Srininvasan, Lulu Basheer, Muhammed Basheer, John Mccarter, Gerry Starrs

Conference papers

Concrete cover provides the first line of defense against the ingress of many deleterious substances into the concrete. Therefore, a measure of its transport properties is vital in assessing its long term performance in a given exposure condition. In new structures the rate of ingress of the deleterious substances could be monitored using array of electrical sensors that are embedded in the cover concrete. For structures that are currently in service, tests can be performed by removing cores from the structure (lab based tests) or by using tests that can be performed on the surface (in situ tests). Results relating …


Behavior Of Externally Bonded Fiber Reinforced Polymer Systems For Strengthening Concrete Girders In Shear, Michael Shawn Murphy Jan 2010

Behavior Of Externally Bonded Fiber Reinforced Polymer Systems For Strengthening Concrete Girders In Shear, Michael Shawn Murphy

Doctoral Dissertations

"Deficiencies in shear resistance are a primary concern in concrete members due to the sudden and unpredictable nature of shear failures. Shear deficiencies in concrete structures can arise due to improper design, long-term deterioration, man-made damages, increases in loads, or as a result of over strengthening in flexure. A number of shear strengthening techniques offer a cost effective means for restoring or enhancing the shear capacity of a concrete member. The use of externally bonded fiber reinforced polymers (FRP) is one such technique that has gained recent recognition for its high strength-to-weight ratio and simplicity of application. The development of …


Arsenite Oxidation By Pure Cultures Of Thiomonas Arsenivorans Strain B6 In Bioreactor Systems, Aniruddha Dastidar Jan 2010

Arsenite Oxidation By Pure Cultures Of Thiomonas Arsenivorans Strain B6 In Bioreactor Systems, Aniruddha Dastidar

University of Kentucky Doctoral Dissertations

The removal of arsenic toxicity from water is accomplished by a preliminary preoxidative step transforming the most toxic form, arsenite (As (III)), to the least toxic form, arsenate (As (V)). The potential of As (III) oxidation to As (V) was initially investigated in batch reactors using the chemoautotrophic Thiomonas arsenivorans strain b6 under varying initial As (III) and cell concentrations and at optimal pH and temperature conditions (pH 6.0 and temperature 30°C). The strain b6 completely oxidized As (III) to As (V) during exponential growth phase for lower levels of As (III) concentrations (≤ 100 mg/L) but continued into stationary …


Development Of A Land Use Regression Model To Predict Nitrogen Dioxide Concentrations, Teresa Sosa Jan 2010

Development Of A Land Use Regression Model To Predict Nitrogen Dioxide Concentrations, Teresa Sosa

Open Access Theses & Dissertations

Air pollution is a major environmental concern in the El Paso-Juárez region. According to the Ministry of Environment and Natural Resources (Secretaría de Medio Ambiente y Recursos Naturales, SEMARNAT) the city of Juárez is one of the city's in México with the highest atmospheric levels of pollution because of its accelerated and unplanned urban growth. One air pollutant of concern is nitrogen dioxide (NO2) due to its detrimental health effects that have been associated with airway inflammation in healthy people and increased respiratory symptoms in people with asthma. Land use regression modeling is a GIS based approach that seeks to …


Controlling Features And Processes For Radionuclide Release From Unsaturated Zone Geological Repositories, Lubna K. Hamdan Jan 2010

Controlling Features And Processes For Radionuclide Release From Unsaturated Zone Geological Repositories, Lubna K. Hamdan

Open Access Theses & Dissertations

In the long run, nuclear waste packages will fail gradually due to localized and general corrosion and radionuclides will be transported to the accessible environment by ground water.

Two main failure scenarios are expected for the waste packages: Flow-through model and bathtub model; in the flow-through model water flows through the waste container, while in the bathtub model water pools inside the waste package. The Department of Energy, in their performance assessment of the proposed repository at Yucca Mountain, excluded the bathtub model from their analysis and assumed the diffusion and advection to be in the same direction in the …


Reclamation Of Salt From Brine Springs, Tejaswini Anand Jan 2010

Reclamation Of Salt From Brine Springs, Tejaswini Anand

Open Access Theses & Dissertations

Sodium-chloride brine underlies the shallow subsurface and discharges in springs and streams at numerous locations in Kent and Stonewall Counties in Central Texas. These discharges eventually flow into the Salt Fork of the Brazos River, lowering the quality of this important surface water resource. One potentially cost effective solution for the problem of excess salt loading to the Brazos River by brine spring discharge is to intercept brine groundwater discharges and either treat or evaporate the water. We have examined the energetic of desalinating and evaporating the water from the brine to produce marketable salt products and distilled water. Our …


Service Life Prediction Of Pier For The Existing Reinforced Concete Bridges In Chloride-Laden Environment, Ming-Te Liang, Ran Huang, Shen-An Feng, Chi-Jang Yeh Dec 2009

Service Life Prediction Of Pier For The Existing Reinforced Concete Bridges In Chloride-Laden Environment, Ming-Te Liang, Ran Huang, Shen-An Feng, Chi-Jang Yeh

Journal of Marine Science and Technology–Taiwan

The prediction method of service life for bridge structures is played an important role of bridge management system. In this paper, the mathematical modeling was to study the servise life prediction of pier for existing reinforced concrete (RC) bridge exposed to chloride environment. The corrosion process has three stages, the initiation time (tc), the depassivation time (tp), and the corrosion (propagation) time (tcorr). The total service life of pier for the existing RC bridge can be expressed as t = tc + tp + tcorr. Many mathematical models were applied to predicting each value of the tc, tp, and tcorr. …


Production Of Iron Using Environmentally-Benign Renewable Or Recycled Reducing Agents, Timothy C. Eisele, Surendra Komar Kawatra Dec 2009

Production Of Iron Using Environmentally-Benign Renewable Or Recycled Reducing Agents, Timothy C. Eisele, Surendra Komar Kawatra

Michigan Tech Patents

To produce metallic iron from iron ore, a composition comprising a mass of material formed from a mixture of iron ore particles and particles of a reductant that is either a biomass material in particulate form or a plastic resinous material in particulate form is used. The reductant can also be a mixture of biomass material and resin in any proportions. The mass of material comprises at least one body having a shape adapted for smelting such as pellets, briquettes, pieces or lumps. The pellets have sufficient cohesion to maintain the shape into which they have been formed. The invention …


Degradation Of The Bond Strength Between Rebar And Concrete Due To The Impressed Cathodic Current, Jiang-Jhy Chang, Weichung Yeih, Ran Huang Dec 2009

Degradation Of The Bond Strength Between Rebar And Concrete Due To The Impressed Cathodic Current, Jiang-Jhy Chang, Weichung Yeih, Ran Huang

Journal of Marine Science and Technology–Taiwan

In this study, the degradation of the bond strength between the steel rebar and concrete by the impressed cathodic current was investigated. Experimental results showed that the bond strength degraded as the charging current density and the polarization time increased basically. A new parameter representing the total transferred electrons per unit protected area was proposed, and the bond strength was found to decrease as the parameter increased after some value.


Live Load Models For Long Span Bridges, Marta Lutomirska Dec 2009

Live Load Models For Long Span Bridges, Marta Lutomirska

Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research

In the doctoral dissertation a live load model for long span structures was derived. The live load model is valid for spans between 600 ft and 5000 ft and it is intended to reflect current traffic patterns, quantities of trucks and their weights. The live load models available were developed for short and medium span bridges. Those models were not appropriate for long span bridges due to different types of structure and critical traffic patterns. Live load on long spans depends on traffic mix. One heavily overloaded truck does not have significant influence. Moreover, the continuous increase in the number …


Updating And Enhancing The Indiana Bridge Management System (Ibms), Kumares C. Sinha, Samuel Labi, Bobby G. Mccullouch, Abhishek Bhargava, Qiang Bai Dec 2009

Updating And Enhancing The Indiana Bridge Management System (Ibms), Kumares C. Sinha, Samuel Labi, Bobby G. Mccullouch, Abhishek Bhargava, Qiang Bai

JTRP Technical Reports

The Indiana Bridge Management System (IBMS) software package, considered one of the few bridge management system software packages in the United States, possesses several unique features such as multiple criteria analysis but has not been used to its full capabilities because of coding language, outmoded operating system, and other software-related problems. Also, the framework lacked certain considerations such as a preventive maintenance component. In addressing this issue, this study reviewed the existing internal logic of IBMS, and updated some of the cost and deterioration models to include preventive maintenance considerations in the decision tree. Also, the IBMS operating system and …