Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Civil Engineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 871 - 900 of 1777

Full-Text Articles in Entire DC Network

Normal-Strength And High-Strength Concrete Columns Under Cyclic Axial Load And Biaxial Moment, Mehdi Zarei Jan 2016

Normal-Strength And High-Strength Concrete Columns Under Cyclic Axial Load And Biaxial Moment, Mehdi Zarei

Dissertations

The technique of using Carbon Fiber Reinforced Polymer (CFRP) materials to repair and strengthen various concrete members has become popular in the structural retrofitting field as an effective way to enhance the strength and ductility of concrete members due to its superior mechanical properties. In this study a method was introduced to study the behavior of concrete columns with and without CFRP jackets under constant axial load and variable lateral load. The lateral load was applied monotonically and cyclically. To predict the behavior of concrete columns under monotonic and cyclic compressive loadings, a computer code was developed to produce the …


Evaluating A New Cem Iii/A Cement For Concretes Exposed To Harsh Acid Rich Environments, David Thompson, Niall Holmes, John Reddy Jan 2016

Evaluating A New Cem Iii/A Cement For Concretes Exposed To Harsh Acid Rich Environments, David Thompson, Niall Holmes, John Reddy

Conference papers

The Irish Annex to the European specification, performance, production and conformity of concrete, IS EN 206, recommends CEM III/B cement for acid rich environments containing between 66 to 80% GGBS. However, BS 8500, the UK annex to EN 206 and the British Research Establishment (BRE) Special Digest 1, recommends CEM III/A cement with a GGBS range of 36-65%. This project investigated the performance of a new CEM III/A cement produced by Ecocem Ireland in concretes exposed to such environments using an extensive suite of laboratory tests.

In Ireland, up to €5.8bn will be invested to provide fresh drinking water and …


Kinetic Energy Harvesting Mechanism For Vortex Drop Structures, Mungtra Chusilp Jan 2016

Kinetic Energy Harvesting Mechanism For Vortex Drop Structures, Mungtra Chusilp

Doctoral Dissertations

Energy recovery from wastewater is gaining significance as utilities work toward achieving energy neutrality and sustainability in their wastewater collection and treatment systems. In this dissertation, kinetic energy harvesting mechanism for vortex drop structures found within the municipal waste and storm water conveyance systems is presented. There are thousands of sewer drop structures installed across the U.S. carrying billions of gallons of sewage each year. A custom micro water turbine is developed in this research which could be retrofitted within the existing drop shafts to harvest the excessive kinetic energy available. This dissertation presents the conceptual design and analysis of …


Rehabilitation And Strengthening Of Reinforced Concrete Members Using A Fiber Reinforced Cementitious Matrix Composite, Zena Riyadh Aljazaeri Jan 2016

Rehabilitation And Strengthening Of Reinforced Concrete Members Using A Fiber Reinforced Cementitious Matrix Composite, Zena Riyadh Aljazaeri

Doctoral Dissertations

“Externally bonded fiber reinforced cementitious matrix (FRCM) for structural members was tested and evaluated as a new class of composite material for repairing and strengthening infrastructures. In comparison with fiber reinforced polymer (FRP) composites, FRCM composite has a superior high temperature resistance and great compatibility with concrete substrates. Experimental investigation is ongoing in the United States to evaluate the structural and durability performance of FRCM composite to be implemented in field applications. This experimental program consisted of testing 12 strengthened reinforced concrete (RC) beams to study the fatigue and flexure performance under environmental exposure and sustained stress, 10 strengthened RC …


Circular Rc Columns Partially Confined With Frp, Sahar Y. Ghanem Jan 2016

Circular Rc Columns Partially Confined With Frp, Sahar Y. Ghanem

Theses and Dissertations--Civil Engineering

Wrapping reinforced concrete (RC) columns with Fiber Reinforced Polymer (FRP) composites is effective in increasing their capacity. The current state of art concentrates primarily on fully wrapped RC columns and few studies dealt with partially wrapped columns. The majority of the studies did not account for the influence of the existing steel reinforcement on the column’s behavior. Other studies estimated the total confinement pressure as the sum of the confinement pressure due to the external FRP jacketing and due to the internal transverse steel reinforcement. Few models dealt with the coupled effect of the confinement from steel and partial FRP …


Transient-Based Risk Analysis Of Water Distribution Systems, Steven Hoagland Jan 2016

Transient-Based Risk Analysis Of Water Distribution Systems, Steven Hoagland

Theses and Dissertations--Civil Engineering

Water distribution system utilities must be able to maintain a system’s assets (i.e., pumps, tanks, water mains, etc.) in good working condition in order to provide adequate water quantity and quality to its customers. Various asset management approaches are employed by utilities in order to make optimal decisions regarding the renewal of system components. Part of a good asset management approach is performing a comprehensive risk analysis which consists of considering all potential ways in which the system may fail, the likelihood failure of for each scenario, and the consequences of said failure. This study investigates a water distribution system’s …


Tier 1 Highway Security Sensitive Material Dynamic Risk Management, Steven Douglas Kreis Jan 2016

Tier 1 Highway Security Sensitive Material Dynamic Risk Management, Steven Douglas Kreis

Theses and Dissertations--Civil Engineering

Each year, over 2 billion tons of hazardous materials are shipped in the United States, with over half of that being moved on commercial vehicles. Given their relatively poor or nonexistent defenses and inconspicuousness, commercial vehicles transporting hazardous materials are an easy target for terrorists. Before carriers or security agencies recognize that something is amiss, their contents could be detonated or released. From 2006 to 2015, the U.S. Department of Transportation’s Pipeline and Hazardous Materials Safety Administration (PHMSA) recorded 144,643 incidents involving a release of hazardous materials. Although there were no known instances of terrorism being the cause, accidental releases …


Composite Confinement Systems For Rc Column Repair And Construction Under Seismic Loads: Concept, Characterization And Performance, Mostafa Fakharifar Jan 2016

Composite Confinement Systems For Rc Column Repair And Construction Under Seismic Loads: Concept, Characterization And Performance, Mostafa Fakharifar

Doctoral Dissertations

"This study aims at developing, characterizing and validating an integrated composite confinement system of conventional jackets for: (1) repair and retrofit of existing bridge columns; and (2) construction of new bridge columns, subjected to earthquake excitations.

A new composite steel confinement jacket was proposed by combining a thin steel sheet and prestressing strands as a hybrid jacket, incorporating active and passive confining pressure on damaged RC columns. Both experimental and analytical studies were conducted to understand the performance and effectiveness of the proposed repair method. The experimental study involved two 1/2-scale lap-spliced deficient RC bridge columns originally tested to failure …


Precast Full-Depth Deck Panels Supported On Inverted Bulb-Tee Bridge Girders, Michael James Mingo Jan 2016

Precast Full-Depth Deck Panels Supported On Inverted Bulb-Tee Bridge Girders, Michael James Mingo

Electronic Theses and Dissertations

The South Dakota Department of Transportation (SDDOT) currently uses precast double-tee bridge deck systems for many of its county bridges because they are economical and fast in construction. Current bridges are designed for a service life of 75 years. However, many double-tee girder bridges are deteriorating and some need total replacement after 40 years in service. Furthermore, the double-tee bridge system only has one supplier in South Dakota. Alternative durable precast or prefabricated bridge systems are needed to provide more options to local governments when designing a new bridge. Different alternatives will also give local governments more flexibility to select …


Reuse Of Aqueous Waste Streams For Transportation-Related Applications, Gregory L. Hansen Jan 2016

Reuse Of Aqueous Waste Streams For Transportation-Related Applications, Gregory L. Hansen

Electronic Theses and Dissertations

Aqueous waste streams produced from commercial, industrial, and municipal processes may be potentially reused for transportation applications. The objectives of this project were to identify potential transportation-related applications for aqueous waste streams available in South Dakota, develop guidance for the beneficial reuse of aqueous waste streams, and evaluate the reuse of MIEX® brine generated by the Watertown Municipal Water Treatment Plant (WMWTP). This study identified many aqueous wastes from municipal water and wastewater treatment facilities, industrial and agricultural processes in South Dakota that can be potentially used for ice and dust control. Beneficial reuse of these waste streams requires a …


Using Photovoltaics To Power Electrochemical Chloride Extraction From Concrete, Sean Bond, Lynette O'Callaghan, Niall Holmes Dr., Brian Norton Jan 2016

Using Photovoltaics To Power Electrochemical Chloride Extraction From Concrete, Sean Bond, Lynette O'Callaghan, Niall Holmes Dr., Brian Norton

Conference papers

Corrosion of embedded steel in reinforced concrete (RC) is a world-wide problem, that reduces structural performance and lifespan. Chloride attack may be a result of seawater, de-icing salts or contaminated admixtures, brought on by ingress of chlorides into the concrete. Electrochemical Chloride Extraction (ECE) is a non-destructive treatment for contaminated RC structures, that due to uncertainty of treatment times and applied current densities, is only 50% effective. It is often diesel powered has an environmental impact and often very costly due to the long treatment times. To improve the efficiency of ECE the influences of concrete resistance, cement type and …


Finite Element Modeling Of Frp Strengthened Concrete Beams And Columns At Different Temperatures, Bassma Ibrahim Gawil Jan 2016

Finite Element Modeling Of Frp Strengthened Concrete Beams And Columns At Different Temperatures, Bassma Ibrahim Gawil

Wayne State University Dissertations

FINITE ELEMENT MODELING OF FRP STRENGTHENED CONCRETE BEAMS

AND COLUMNS AT DIFFERENT TEMPERATURES

By

BASSMA I. GAWIL

October 2016

Advisor: Dr. Hwai-Chung Wu

Major: Civil and Environmental Engineering (Structural Engineering)

Degree: Doctor of Philosophy

Collapse of buildings or bridges is one of the worst scenarios to which built-infrastructure

may be subjected during their lifetime. In recent years, due to external environmental conditions

(temperature and humidity). Often times these effects are not immediately evident and develop

years later – making determination of responsibility difficult and repair expensive.

Fiber reinforced polymer (FRP) has proven efficient and economical for the development

and repair …


Behavior Of Hollow-Core Composite Columns Under Torsion Loading, Sujith Anumolu Jan 2016

Behavior Of Hollow-Core Composite Columns Under Torsion Loading, Sujith Anumolu

Masters Theses

"The effect of torsional loads could be significant along with axial and flexural loads on bridge columns during earthquake excitations. The present study presents the torsional behavior of hollow-core steel-concrete-steel columns (HC-SCS) and hollow-core fiber reinforced polymer-concrete-steel columns (HC-FCS). The HC-SCS comprises of sandwiched concrete shell between two steel tubes whereas in HC-FCS column, the outer steel tube of HC-SCS column was replaced by the FRP tube. Both columns have stay-in place permanent form-work to the concrete shell in the form of outer and inner tubes. The steel tubes serve as longitudinal and shear reinforcement to the column. Finite element …


Mechanistic Behavior Of Uhpc And Uhpc Composite Structural Components, Munaf Al-Ramahee Jan 2016

Mechanistic Behavior Of Uhpc And Uhpc Composite Structural Components, Munaf Al-Ramahee

Electronic Theses and Dissertations

The resistance of reinforced concrete is mobilized through the composite action of two materials with different mechanical behaviors and physical features. Enabling the composite action requires a transfer mechanism between the concrete and the reinforcement which is referred to as bond. The bond model can be defined as a traction-slip relation tangent to the interface. The bond strength between different types of concrete, internal reinforcement, and external reinforcement has been of interest to structural engineers for decades. Experimental tests have been carried out to validate the existing bond models and introduce new bond models for special cases of concrete or …


Probability-Based Hurricane Resilience Evaluation And Retrofitting For Residential Community, Yadong Dong Jan 2016

Probability-Based Hurricane Resilience Evaluation And Retrofitting For Residential Community, Yadong Dong

Dissertations, Master's Theses and Master's Reports

Wood residential construction is vulnerable to hurricanes, as evident in recent hurricane events. Many studies indicated that the changing climate may very likely alter hurricane patterns, which could lead to more severe hurricane damage to the wood residential construction that accounts for 90% of the residence in the USA. On the other hand, deterioration of material increases the chance of structural failure by reducing the structural capacity (e.g., corrosion of fasteners in roof panel could significantly reduce the withdrawal capacity of the roofing structure during hurricane events).

Currently, most hurricane damage estimations only focus on direct loss (e.g., structural loss). …


Behavior Of Concrete Beams With Corroded Reinforcement Retrofitted With Carbon Fiber Reinforced Polymer, Needa Marwan Lingga Jan 2016

Behavior Of Concrete Beams With Corroded Reinforcement Retrofitted With Carbon Fiber Reinforced Polymer, Needa Marwan Lingga

Civil and Environmental Engineering Master's Project Reports

Severe premature deterioration has been reported in a large number of reinforced concrete (RC) structures in corrosive environments. This research project focused on the behavior of beams that contained corroded steel and were retrofitted with CFRP. The steel in RC beams were assumed to be fully corroded, representing the most severe loss in steel cross-section. Unidirectional CFRP sheets were used to strengthen the deteriorated beams. The experimental program included testing five simply supported rectangular cross section concrete beams. All beams were approximately 1/3rd scale models, 4in. x 6in. cross sections, and 6ft. long. In three beams, the oiled steel …


Behavior Of Ultra-High Performance Concrete Bridge Deck Panels Compared To Conventional Stay-In-Place Deck Panels, Valter Gora Venancio Jan 2016

Behavior Of Ultra-High Performance Concrete Bridge Deck Panels Compared To Conventional Stay-In-Place Deck Panels, Valter Gora Venancio

Masters Theses

"The remarkable features of ultra-high performance concrete (UHPC) have been reported. Its application in bridge construction has been an active research area in recent years, attributed to its higher compressive strength, higher ductility and reduced permeability when compared with conventional concrete and even high-strength concrete. Those characteristics are known to increase bridge durability and, consequently, decrease life-cycle maintenance costs.

With that in mind, this study investigated the performance of UHPC stay-in-place (SIP) bridge deck panels subjected to high loads in both flexure and shear. The test matrix consisted of twelve (12) half-scale panels that were 4 feet long and 2 …


Evaluation Of Ultra-High Performance Concrete (Uhpc) In Joints Of Bridge Girders, Saipavan Rallabhandhi Jan 2016

Evaluation Of Ultra-High Performance Concrete (Uhpc) In Joints Of Bridge Girders, Saipavan Rallabhandhi

Masters Theses

"Joints are often considered as the weak link in a structure and often deterioration of the structure initiates from the joints. Joints transfer the stresses from super-structure to sub-structure and in this process are subjected to large transfer stresses. Not much attention is given to the design of joints as they are positioned in low moment regions and typically a 4 to 6 ksi (28 to 41 MPa) concrete is used to fill the joints. One of the solution to this problem is Ultra-high performance concrete (UHPC). In the recent past significant research has been done to use UHPC in …


Corrosion Protection Systems In Offshore Structures, Hristo Ivanov Jan 2016

Corrosion Protection Systems In Offshore Structures, Hristo Ivanov

Williams Honors College, Honors Research Projects

Corrosion plays a pivotal role in the engineering world. Engineers of all disciplines must consider the dangers that this phenomenon can incur. Interestingly, corrosion mitigation is not a topic that is addressed in most academic curricula. The goal of this paper is to give engineering students a brief introduction into corrosion and some of the prevention techniques commonly used today.

The design of a corrosion protection system for offshore structures is discussed in order to illustrate how these techniques can be utilized even in the most extreme environments. First, the driving force behind corrosion is examined, introducing the basic mechanics …


Operational And Water Quality Analysis For The City Of Akron's Water Treatment Plant And Distribution System, Chelsea James Jan 2016

Operational And Water Quality Analysis For The City Of Akron's Water Treatment Plant And Distribution System, Chelsea James

Williams Honors College, Honors Research Projects

Chlorination is one of the most common methods of treating pathogens and ensuring microbial water quality in water treatment and distribution. As chlorinated water leaves the source and travels through the water distribution system, the chlorine reacts with both the organic compounds (dissolved organic carbon, DOC) in the source water and the corrosion or biofilm of the pipe walls. The chlorine concentration, or chlorine residuals, at any point in the water distribution system is a good measure of water quality. At the same time, chlorination produces disinfection byproducts as the chlorine also reacts with other naturally-occurring materials in the water. …


An Overview Of The Development Of Cement-Based Batteries For The Cathodic Protection Of Embedded Steel In Concrete, Aimee Byrne, Niall Holmes, Brian Norton Jan 2016

An Overview Of The Development Of Cement-Based Batteries For The Cathodic Protection Of Embedded Steel In Concrete, Aimee Byrne, Niall Holmes, Brian Norton

Conference papers

This paper presents an overview of the cement-based batteries developed in DIT for use in the cathodic protection of embedded steel in reinforced concrete undergoing chloride-induced corrosion. Cathodic protection delivers an external current (approximately 20mA per m2 of embedded steel) which effectively polarises the internal current generated during corrosion. The batteries developed in DIT comprise of a cement-based electrolyte containing different additives including sand, aggregate, salts, carbon black and plasticiser with protruding anode and cathode metal plates. These batteries produced an initial electrical output of 1.5V and 23mA through a 10 resistor as measured using data acquisition units and a …


Evaluation Of Concrete Degradation Using Acoustic Emission: Data Filtering And Damage Detection, Marwa A. Abdelrahman Jan 2016

Evaluation Of Concrete Degradation Using Acoustic Emission: Data Filtering And Damage Detection, Marwa A. Abdelrahman

Theses and Dissertations

The prevalence of aging and deteriorating infrastructure in the U.S. has raised concerns regarding its level of serviceability, reliability, and vulnerability to natural disasters. This issue has gained attention recently and efforts are being conducted to accelerate the delivery of enhanced nondestructive testing (NDT) and structural health monitoring (SHM) methods. Acoustic emission (AE) is a strong candidate for these applications due to its high sensitivity and potential for damage detection in different materials. However, several challenges associated with the technique hinder the development of automated, reliable, real-time SHM using AE.

This study aims to advance the use of AE for …


Independency Of Elasticity On Residual Stress Of Room Temperature Rolled Stainless Steel 304 Plates For Structure Materials, Parikin Parikin, David Allen Dec 2015

Independency Of Elasticity On Residual Stress Of Room Temperature Rolled Stainless Steel 304 Plates For Structure Materials, Parikin Parikin, David Allen

Makara Journal of Technology

Mechanical strengths of materials are widely expected in general constructions of any building. These properties depend on its formation (cold/hot forming) during fabrication. This research was carried out on cold-rolled stainless steel (SS) 304 plates, which were deformed to 0, 34, 84, and 152% reduction in thickness. The tests were conducted using Vickers method. Ultra micro indentation system (UMIS) 2000 was used to determine the mechanical properties of the material, i.e.: hardness, modulus elasticity, and residual stresses. The microstructures showed lengthening outcropping due to stress corrosion cracking for all specimens. It was found that the tensile residual stress in a …


Estimation Of Rebar Corrosion In Concrete Using Ground Penetrating Radar, Rakesh Krishnarajapete Raju Dec 2015

Estimation Of Rebar Corrosion In Concrete Using Ground Penetrating Radar, Rakesh Krishnarajapete Raju

Civil Engineering Theses - Archive

The purpose of this research was to quantitatively relate the amount of rebar corrosion in concrete with the amplitude of electromagnetic waves generated from Ground penetrating radar (GPR). Many studies have been undertaken on qualitative measurement of corrosion, but there are very few studies regarding estimation of rebar corrosion quantitatively. This experiment involved the use of accelerated corrosion by impressed current technique to corrode the rebar inside the concrete and GPR to determine the extent of corrosion, while making a comparison with a stainless steel bar which was used as a cathode to create a galvanic cell action. Rebars were …


Slope Stabilization And Performance Monitoring Of I-35 And Sh-183 Slopes Using Recycled Plastic Pins, Sandip Tamrakar Dec 2015

Slope Stabilization And Performance Monitoring Of I-35 And Sh-183 Slopes Using Recycled Plastic Pins, Sandip Tamrakar

Civil Engineering Theses - Archive

The United States earth retaining structure market exceeds 170 million square feet annually and there are over 50 different retaining systems to select from which are unique in design and construction. Depending on the type of retaining structure, unit costs vary from less than $20 to in excess of $250 per square foot. Selecting the technically appropriate and cost-effective system is often critical to project cost and schedule. The Recycled Plastic Pin (RPP) has potential to be utilized as a sustainable and cost effective option to stabilize the surficial slope failure. RPP have been successfully used in Missouri, Iowa and …


Assessing The Water Quality Benefits Of Green Infrastructure Stormwater Control Measures., Sam Abdollahian Dec 2015

Assessing The Water Quality Benefits Of Green Infrastructure Stormwater Control Measures., Sam Abdollahian

Electronic Theses and Dissertations

Permeable pavements systems and tree boxes are a common type of Green Infrastructure (GI) Stormwater Control Measures (SCMs) that are often used for mitigating the stormwater runoff. In this study two permeable pavement systems and a tree box installed along parking lanes of an urban street in Louisville, KY, were investigated to evaluate their performance on improving stormwater runoff quality. The water quality monitoring was accomplished by analysis of samples collected from stormwater runoff and the captured stormwater volume at the bottom of the permeable pavements’ sub-base reservoir and by a drain gauge (lysimeter) installed in the tree box. Pollutants …


Alkali-~Activated Fly Ash Binders: Feasibility As A Sustainable Alternative To Ordinary Portland Cement For Pre-~Cast Systems, Kimberly Sierra Dec 2015

Alkali-~Activated Fly Ash Binders: Feasibility As A Sustainable Alternative To Ordinary Portland Cement For Pre-~Cast Systems, Kimberly Sierra

UNLV Theses, Dissertations, Professional Papers, and Capstones

Fresh, load-dependent, transport, and durability properties of alkali-activated fly ash mortars were studied. The influences of activator concentration, solution-to-binder ratio, curing condition, activator type, and sodium silicate-to-total solution ratio on the properties of the studied alkali-activated mortars were examined. This study was divided in two phases. The first phase dealt with the use of sodium hydroxide as the sole activator. The second phase of the study was divided into two parts, both of which used a combination of sodium hydroxide and sodium silicate as the activator solution. Part I of phase II used elevated temperature curing conditions, whereas part II …


Corrosion Of Steel In Submerged Concrete Structures, Michael Thomas Walsh Nov 2015

Corrosion Of Steel In Submerged Concrete Structures, Michael Thomas Walsh

USF Tampa Graduate Theses and Dissertations

This investigation determined that severe corrosion of steel can occur in the submerged portions of reinforced concrete structures in marine environments. Field studies of decommissioned pilings from actual bridges revealed multiple instances of strong corrosion localization, showing appreciable local loss of steel cross-section. Quantitative understanding of the phenomenon and its causes was developed and articulated in the form of a predictive model. The predictive model output was consistent with both the corrosion rate estimates and the extent of corrosion localization observed in the field observations. The most likely explanation for the observed phenomena that emerged from the understanding and modeling …


Reducing The Porosity And Sealing Cracks By Using Crystalline Admixture In Conventional Concrete, Visar Krelani, Liberato Ferrara Nov 2015

Reducing The Porosity And Sealing Cracks By Using Crystalline Admixture In Conventional Concrete, Visar Krelani, Liberato Ferrara

UBT International Conference

There is a continuous increase of quality on civil engineering materials in developed countries and parallel increase of need for new constructions in developing countries. Professional community should propose solutions for the durability that can resist in different severe environments. The most important factor that can affect concrete durability is represented by the pore distribution. Transport properties can take place through the porous network inside the cementitious composites and the aggregates interface, permitting the ingress of aggressive agents damaging concrete function intrinsically as a material and the well-functioning of the entire structure. The use of a crystalline admixture during the …


Feasibility Of Cathodic Protection In Grouted Post Tensioned Tendons - Exploratory Model Calculations, Jacob Dharma Bumgardner Nov 2015

Feasibility Of Cathodic Protection In Grouted Post Tensioned Tendons - Exploratory Model Calculations, Jacob Dharma Bumgardner

USF Tampa Graduate Theses and Dissertations

Recent corrosion related failures of grouted post tensioned tendons, even after the introduction of improved grouts, have led to renewed interest in supplemental or backup means of corrosion control for these systems. A finite element model is presented to explore feasibility of impressed current cathodic protection of strand in grouted tendons. The model examines polarization evolution as function of service time and includes consideration of anode placement and size, grout porosity, pore water alkalinity, electrochemical species diffusivity and applied voltage on the polarization efficacy and durability of such a system. The exploratory model projections suggested that, within the context of …