Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 151 - 160 of 160

Full-Text Articles in Entire DC Network

Model And Clinical Device Development For Noninvasive Diagnosis Of Low Back Pain And Dysfunction, Ravi Patraju Jan 1999

Model And Clinical Device Development For Noninvasive Diagnosis Of Low Back Pain And Dysfunction, Ravi Patraju

Theses

Millions of people suffer from acute or chronic low back pain. In order for proper treatment to be administered, a patient must receive an accurate diagnosis. Therefore, it is critical to develop an objective model to measure the motion and any dysfunction of a patient's low back. Only then can a physician effectively implement the correct therapy and measure its effectiveness through follow-up to minimize or eliminate low back pain.

Numerous cadaveric, active and passive studies have been done to understand the mechanics of low back disorders. However, only living human subjects suffer from low back pain and therefore cadaveric …


Measurement Of The Baroreceptor Sensitivity Index (Brsi) In The Frequency Domains, Tanvir Raquib Aug 1998

Measurement Of The Baroreceptor Sensitivity Index (Brsi) In The Frequency Domains, Tanvir Raquib

Theses

Time domain analysis for calculating the Baroreceptor Sensitivity Index (BRSI) did not always provide an accurate result. It also had another limitation in that it could not show the influence of the autonomic nervous system for different subjects. The correlation coefficient is a mechanism that was used to either accept or reject the BRSI values in the time domain but the correlation coefficient values changed drastically depending on how many sample points were selected for the calculation.

On the other hand, frequency domain analysis for the BRSI calculation was relatively easier and provided more accurate information compared to the time …


Using Heart Variability To Measure The Effects Of Manual Medicine On Autonomic Activity, Michael Zullow Oct 1997

Using Heart Variability To Measure The Effects Of Manual Medicine On Autonomic Activity, Michael Zullow

Theses

A pilot study was performed to test the theory that manual medicine techniques known as the CV4 (compression of fourth cerebral ventricle) maneuver and a sacral hold/iliac bridge hold combination increase parasympathetic activity. Manual medicine techniques are widely practiced by Doctors of Osteopathy and Chiropractors to treat physical and mental health problems. Those who have received manual therapy have reported to experience less pain, better mobility, and a greater feeling of relaxation. To help us learn about the effects of manual therapy, autonomic activity was measured scientifically rather than subjectively in this study by monitoring respiration rate and heart rate, …


Renin-Angiotensin System And Its Relationship To Arterial Pressure Regulation, Sami D. Saume May 1997

Renin-Angiotensin System And Its Relationship To Arterial Pressure Regulation, Sami D. Saume

Theses

The renal system is known to participate in the natural regulation of blood pressure. A renal system model that simulates interaction responses of renal output to arterial blood pressure was developed. The major components of this model are glomerular filtration rate, tubular sodium reabsorption, the renin-angiotensin system, Aldosterone secretion, and antidiuretic hormone secretion. The model's differential equations were coded using Vissim 1.2 student version. It was found that, the renal output increased as glomerular filtration rate, Aldosterone concentration, and blood pressure increased. Conversely, increasing antidiuretic hormone concentration lead to decreased renal output.

Additionally, Angiotensin II and Aldosterone concentrations increased as …


The Relationship Between Thermoregulatory And Haemodynamic Responses Of The Skin To Relaxation And Stress, Paul O. Nketia May 1997

The Relationship Between Thermoregulatory And Haemodynamic Responses Of The Skin To Relaxation And Stress, Paul O. Nketia

Theses

The present study investigated the effects of stress and relaxation on (1) EEG coherence and (2) peripheral blood flow.

EEG coherence of two meditators in two different but adjacent rooms was measured during eyes opened, eyes closed, single meditation and group meditation. The skin temperatures of the subjects together with their room temperatures were also recorded. EEG coherence plots (Cospar) showed a spread out of the alpha band to the beta, theta and occasionally to the delta wave bands during group meditation. The area above the 0.98 coherence threshold in the alpha band was greater during group meditation than during …


Comparison Of Different Signal Processing Algorithms To Extract The Respiration Waveform From The Ecg, David J. Caggiano May 1996

Comparison Of Different Signal Processing Algorithms To Extract The Respiration Waveform From The Ecg, David J. Caggiano

Theses

Power spectral analysis of heart rate variability is a powerful tool to measure the activity of the parasympathetic division of the autonomic nervous system noninvasively. To determine the parasympathetic activity, the frequency of respiration must be known. However, during ambulatory studies, the frequency of respiration is not acquired. To alleviate this problem, methods have been proposed in the past to derive the respiration from the ECG. Unfortunately, these previous methods are unreliable if the subject's breathing rate is uncontrolled. In this study, four methods to derive the respiration waveform from the electrocardiogram (ECG) were developed. Two leads of ECG and …


Signal Processing Techniques In Heart Rate And Systolic Arterial Blood Pressure Variability Studies, Christopher O'Bara Jan 1996

Signal Processing Techniques In Heart Rate And Systolic Arterial Blood Pressure Variability Studies, Christopher O'Bara

Theses

Power spectral analysis of heart rate and systolic arterial blood pressure variability provides a window to the activity of the autonomic nervous system. To derive power spectra from raw blood pressure and electrocardiogram signals, many steps of signal processing must be performed. Most popular methods of spectral analysis require evenly spaced samples; therefore interpolation and resampling techniques must be used.

The results of the present study indicate that different interpolation techniques result in spectral distortions that vary depending upon the interpolation methods used as well as physiological parameters such as heart and respiration rate. Different interpolation methods applied to heart …


Model Parameter Identification For Rod And Cone Oscillatory Potentials, Kehur Banker Jan 1995

Model Parameter Identification For Rod And Cone Oscillatory Potentials, Kehur Banker

Theses

The use of signal modeling of the oscillatory potential (OP) of the electroretinogram (ERG), in the study of cone-rod interaction is investigated. ERG response data were analyzed for red, orange, blue and white flashes on no background and with red flashes on a blue background (to suppress rod responses). The OP signals were extracted from the ERG by digital bandpass filtering and a signal model was fitted through a simplex algorithm to produce the parameters including "OP envelope-amplitude", latency in terms of "center-time" of the OP-envelope and OP frequency. Amplitude for red flashes with or without a blue background showed …


Three Dimensional Diaphragm Simulation Model For The Relationship Of The Tension, Pressure And Shape, Zhangming He Jan 1994

Three Dimensional Diaphragm Simulation Model For The Relationship Of The Tension, Pressure And Shape, Zhangming He

Theses

Weakness of inspiratory muscles is a major cause of respiratory failure. There are many clinical circumstances in which it may occur. The diaphragm is a major respiratory muscle. It has been difficult to quantify its shape, curvature and length.

To solve this question, a three dimensional diaphragm equation was derived on the, assumption that the diaphragm is only attached at its periphery to the rib cage and the abdomen is filled with fluid. Computer programs were developed to fit the equation to the diaphragm contours obtained from plane X rays.

The results indicate that the ratio of transdiaphragmatic pressure to …


A Multicompartmental Model For The Simulation Of Soluble Gas Exchange In The Lungs, Chitaranjan Varadhan May 1993

A Multicompartmental Model For The Simulation Of Soluble Gas Exchange In The Lungs, Chitaranjan Varadhan

Theses

No abstract provided.