Open Access. Powered by Scholars. Published by Universities.®
Social and Behavioral Sciences Commons™
Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 2 of 2
Full-Text Articles in Social and Behavioral Sciences
A Real-Time In Vivo Dosimetric Verification Method For High-Dose Rate Intracavitary Brachytherapy Of Nasopharyngeal Carcinoma, Zhen-Yu Qi, Xiao-Wu Deng, X Cao, Shao-Min Huang, Michael L. Lerch, Anatoly B. Rosenfeld
A Real-Time In Vivo Dosimetric Verification Method For High-Dose Rate Intracavitary Brachytherapy Of Nasopharyngeal Carcinoma, Zhen-Yu Qi, Xiao-Wu Deng, X Cao, Shao-Min Huang, Michael L. Lerch, Anatoly B. Rosenfeld
Anatoly Rozenfeld
Purpose: A real-time in vivo dosimetric verification method using metal-oxide-semiconductor field effect transistor (MOSFET) dosimeters has been developed for patient dosimetry in high-dose rate (HDR) intracavitary brachytherapy of nasopharyngeal carcinoma (NPC). Methods: The necessary calibration and correction factors for MOSFET measurements in 192Iridium source were determined in a water phantom. With the detector placed inside a custom-made nasopharyngeal applicator, the actual dose delivered to the tumor was measured in vivo and compared to the calculated values using a commercial brachytherapy planning system. Results: Five MOSFETs were independently calibrated with the HDR source, yielding calibration factors of 0.48 ± 0.007 cGymV. …
Improvements In Dose Calculation Accuracy For Small Off-Axis Targets In High Dose Per Fraction Tomotherapy, Nicholas Hardcastle, Adam Bayliss, Jeannie Wong, Anatoly B. Rosenfeld, Wolfgang A. Tome
Improvements In Dose Calculation Accuracy For Small Off-Axis Targets In High Dose Per Fraction Tomotherapy, Nicholas Hardcastle, Adam Bayliss, Jeannie Wong, Anatoly B. Rosenfeld, Wolfgang A. Tome
Anatoly Rozenfeld
Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed "Super Sampling" involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving …