Impact Of Wind Generator Control Strategies On Flicker Emission In Distribution Networks, Lasantha Meegahapola, Sarath Perera Dec 2013

Impact Of Wind Generator Control Strategies On Flicker Emission In Distribution Networks, Lasantha Meegahapola, Sarath Perera

Dr Lasantha G Meegahapola

Renewable power generators are increasingly being integrated to electricity networks to achieve future renewable energy targets in power generation. In particular, wind power generation has already reported substantial penetration levels in electricity networks. Traditionally, flicker phenomenon is considered to be one of the power quality issues in power distribution networks due to fluctuating consumer loads connected to the network. Large-scale integration of wind power generators may create significant voltage fluctuations in distribution feeders due to stochastic and intermittent nature of the wind resources. This study aims to investigate and characterize the flicker emission under different control strategies for DFIG based …


Characterisation Of Flicker Emission And Propagation In Distribution Networks With Bi-Directional Power Flows, D Perera, L Meegahapola, S Perera, P Ciufo Dec 2013

Characterisation Of Flicker Emission And Propagation In Distribution Networks With Bi-Directional Power Flows, D Perera, L Meegahapola, S Perera, P Ciufo

Dr Lasantha G Meegahapola

With the increasing penetration levels of intermittent and fluctuating energy sources such as wind generating systems in the electricity grid, resulting voltage fluctuations and flicker can be expected to become an important power quality considerations. Due to significant bidirectional power flows resulting from large renewable power generation systems connected to downstream, voltage fluctuations may propagate from downstream to upstream. The work presented in this paper investigates and characterises flicker emission and propagation resulting from fluctuating generating sources connected to a distribution network. Mathematical models are developed for flicker emission under different generator control strategies and flicker propagation to upstream network. …


Comparative Analysis Of Dynamic Line Rating Models And Feasibility To Minimise Energy Losses In Wind Rich Power Networks, Mathew Simms, Lasantha Meegahapola Dec 2013

Comparative Analysis Of Dynamic Line Rating Models And Feasibility To Minimise Energy Losses In Wind Rich Power Networks, Mathew Simms, Lasantha Meegahapola

Dr Lasantha G Meegahapola

Wind power generation has indicated an exponential increase during last two decades and existing transmission network infrastructure is increasingly becoming inadequate to transmit remotely generated wind power to load centres in the network. The dynamic line rating (DLR) is one of the viable solutions to improve the transmission line ampacity during high wind penetration without investing on an additional transmission network. The main objective of this study is to identify the basic differences between two main line rating standards, since transmission network service providers (TNSPs) heavily depend on these two standards when developing their line rating models. Therefore, a parameter …


Flicker Propagation Analysis In Distribution Networks With Embedded Generation, D Perera, L Meegahapola, S Perera, P Ciufo Dec 2013

Flicker Propagation Analysis In Distribution Networks With Embedded Generation, D Perera, L Meegahapola, S Perera, P Ciufo

Dr Lasantha G Meegahapola

Embedded generators such as wind generators can produce observable voltage fluctuations during variable wind conditions hence flicker. The flicker produced by such intermittent and fluctuating generating sources can propagate to other parts of the distribution network while creating power quality issues in distribution feeders. This study presents a flicker emission analysis for a doubly-fed induction generator (DFIG) based wind farm and investigate the pertinent factors which influence flicker propagation and attenuation in distribution feeders. Study has shown that voltage fluctuations are significantly influenced by the attenuation characteristics of various load types (i.e. constant power, impedance and current loads) connected to …


Large Networks Of Vertical Multi-Layer Graphenes With Morphology-Tunable Magnetoresistance, Zengji Yue, Igor Levchenko, Shailesh Kumar, Donghan Seo, Xiaolin Wang, S X. Dou, Kostya Ken Ostrikov Dec 2013

Large Networks Of Vertical Multi-Layer Graphenes With Morphology-Tunable Magnetoresistance, Zengji Yue, Igor Levchenko, Shailesh Kumar, Donghan Seo, Xiaolin Wang, S X. Dou, Kostya Ken Ostrikov

Zengji Yue

We report on the comparative study of magnetotransport properties of large-area vertical few-layer graphene networks with different morphologies, measured in a strong (up to 10 T) magnetic field over a wide temperature range. The petal-like and tree-like graphene networks grown by a plasma enhanced CVD process on a thin (500 nm) silicon oxide layer supported by a silicon wafer demonstrate a significant difference in the resistance-magnetic field dependencies at temperatures ranging from 2 to 200 K. This behaviour is explained in terms of the effect of electron scattering at ultra-long reactive edges and ultra-dense boundaries of the graphene nanowalls. Our …


A Multiagent Approach For Decentralized Voltage Regulation In Power Distribution Networks Within Dgs, Fenghui Ren, Minjie Zhang, Danny Sutanto Oct 2013

A Multiagent Approach For Decentralized Voltage Regulation In Power Distribution Networks Within Dgs, Fenghui Ren, Minjie Zhang, Danny Sutanto

Dr Fenghui Ren

Voltage regulation (VR) is a procedure to keep voltages in a distribution network (DN) within normal limits. Conven- tionally, a voltage regulator can read voltage levels from pre- dened measures, and regulate the voltages. However, due to lacking of a distributed generator's (DG) information, the unexpected electricity from a DG will mislead readings on voltages levels, so as to disturb the VR in a DN. Adjust- ing a DG's reactive power output is an alternative way for VR. However, because of limited penetration levels, DGs need to collaborate with other devices in order to provide an eective voltage regulation. Therefore, …


Securing Dsr Against Wormhole Attacks In Multirate Ad Hoc Networks, Shams Qazi, Raad Raad, Yi Mu, Willy Susilo Oct 2013

Securing Dsr Against Wormhole Attacks In Multirate Ad Hoc Networks, Shams Qazi, Raad Raad, Yi Mu, Willy Susilo

Dr Raad Raad

A wormhole attack is one of the hardest problems to detect whereas it can be easily implanted in any type of wireless ad hoc network. A wormhole attack can easily be launched by the attacker without having knowledge of the network or compromising any legitimate nodes. Most existing solutions either require special hardware devices or make strong assumptions in order to detect wormhole attacks which limit the usability of these solutions. In this paper, we present a security enhancement to dynamic source routing (DSR) protocol against wormhole attacks for ad hoc networks which relies on calculation of round trip time …


Comparison Of Methodologies For Assessment Of Harmonic Current Emission Limits For Large Installations Connected To Lv Networks, Biyanvilage Perera, Sarath Perera, Philip Ciufo, Victor J. Gosbell Feb 2013

Comparison Of Methodologies For Assessment Of Harmonic Current Emission Limits For Large Installations Connected To Lv Networks, Biyanvilage Perera, Sarath Perera, Philip Ciufo, Victor J. Gosbell

Dr Philip Ciufo

With the proliferation of large, disturbing installations (loads and distribution generators) connected to public low voltage networks, managing the harmonic voltage levels in the network has become a key concern to distribution network service providers (DNSPs). Therefore, it is important that DNSPs limit the harmonic current emission by individual installations. This paper reviews a number of methodologies that exist in the current technical literature in relation to the assessment of harmonic current emission limits for disturbing installations connected to the public LV network. Application of these methodologies is demonstrated through a case study on a test network. The study shows …


Flicker Propagation Analysis In Distribution Networks With Embedded Generation, D Perera, L Meegahapola, S Perera, P Ciufo Feb 2013

Flicker Propagation Analysis In Distribution Networks With Embedded Generation, D Perera, L Meegahapola, S Perera, P Ciufo

Dr Philip Ciufo

Embedded generators such as wind generators can produce observable voltage fluctuations during variable wind conditions hence flicker. The flicker produced by such intermittent and fluctuating generating sources can propagate to other parts of the distribution network while creating power quality issues in distribution feeders. This study presents a flicker emission analysis for a doubly-fed induction generator (DFIG) based wind farm and investigate the pertinent factors which influence flicker propagation and attenuation in distribution feeders. Study has shown that voltage fluctuations are significantly influenced by the attenuation characteristics of various load types (i.e. constant power, impedance and current loads) connected to …