Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Physical Sciences and Mathematics

Separation Of The Ribbon From Globally Distributed Energetic Neutral Atom Flux Using The First Five Years Of Ibex Observations, N. A. Schwadron, E. Moebius, S. A. Fuselier, D. J. Mccomas, H. O. Funsten, Paul H. Janzen, Daniel B. Reisenfeld, H. Kucharek, M. A. Lee, K. Fairchild, F. Allegrini, M. Dayeh, G. Livadiotis, M. Reno, M. Bzowski, J. M. Sokol, M. A. Kubiak, E. R. Christian, R. Demajistre, P. Frisch, A. Galli, P. Wurz, M. Gruntman Nov 2014

Separation Of The Ribbon From Globally Distributed Energetic Neutral Atom Flux Using The First Five Years Of Ibex Observations, N. A. Schwadron, E. Moebius, S. A. Fuselier, D. J. Mccomas, H. O. Funsten, Paul H. Janzen, Daniel B. Reisenfeld, H. Kucharek, M. A. Lee, K. Fairchild, F. Allegrini, M. Dayeh, G. Livadiotis, M. Reno, M. Bzowski, J. M. Sokol, M. A. Kubiak, E. R. Christian, R. Demajistre, P. Frisch, A. Galli, P. Wurz, M. Gruntman

Physics and Astronomy Faculty Publications

The Interstellar Boundary Explorer (IBEX) observes the IBEX ribbon, which stretches across much of the sky observed in energetic neutral atoms (ENAs). The ribbon covers a narrow (∼20–50) region that is believed to be roughly perpendicular to the interstellar magnetic field. Superimposed on the IBEX ribbon is the globally distributed flux that is controlled by the processes and properties of the heliosheath. This is a second study that utilizes a previously developed technique to separate ENA emissions in the ribbon from the globally distributed flux. A transparency mask is applied over the ribbon and …


Size Dependence Of Static And Dynamic Magnetic Properties In Nanoscale Square Permalloy Antidot Arrays, Minghui Yu, Leszek M. Malkinski, Leonard Spinu, Weilie Zhou, Scott L. Whittenburg Mar 2007

Size Dependence Of Static And Dynamic Magnetic Properties In Nanoscale Square Permalloy Antidot Arrays, Minghui Yu, Leszek M. Malkinski, Leonard Spinu, Weilie Zhou, Scott L. Whittenburg

Chemistry and Biochemistry Faculty Publications

Permalloy antidot arrays with different square hole sizes ( , , and ) have been fabricated by means of electron-beam lithography and lift-off techniques. The smaller square hole size results in enhanced remanence and reduced coercivity in the antidot array. Multiple resonance modes were clearly observed for the magnetic field applied normal to the array plane, and double uniform resonance modes occurred when the field deviated more than 30° from the normal to the plane. Two distinct dipolar field patterns with different orientations and magnitudes split the uniform resonance into double resonance modes. The double resonance modes show uniaxial in-plane …