Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material – A Longitudinal Study, Adela Rabell-Montiel, Jacinta Browne, Stephen Pye, Tom Anderson, Carmel Moran Jul 2017

Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material – A Longitudinal Study, Adela Rabell-Montiel, Jacinta Browne, Stephen Pye, Tom Anderson, Carmel Moran

Articles

Commercially available ultrasound quality assurance test phantoms rely upon the long-term acoustic stability of tissue-mimicking-materials (TMMs). The measurement of the acoustic properties can be technically challenging and it is important to ensure its stability. The standard technique is to film-wrap samples of TMM and to measure the acoustic properties in a water bath. In this study, a modified technique is proposed whereby the samples of TMM are measured in a preserving fluid that is intended to maintain their characteristics. The acoustic properties were evaluated using a broadband pulse-echo substitution technique over the frequency range of 4.5 – 50 MHz at …


Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material: A Longitudinal Study, A. Rabell-Montiel, Jacinta Browne, S. D. Pye, T. A. Anderson, C. Moran Jan 2017

Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material: A Longitudinal Study, A. Rabell-Montiel, Jacinta Browne, S. D. Pye, T. A. Anderson, C. Moran

Articles

Commercially available ultrasound quality assurance test phantoms rely on the long-term acoustic stability of the tissue-mimicking-material (TMM). Measurement of the acoustic properties of the TMM can be technically challenging, and it is important to ensure its stability. The standard technique is to film-wrap samples of TMM and to measure the acoustic properties in a water bath. In this study, a modified technique was proposed whereby the samples of TMM are measured in a preserving fluid that is intended to maintain their characteristics. The acoustic properties were evaluated using a broadband pulse-echo substitution technique over the frequency range 4.5–50 MHz at …


Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material: A Longitudinal Study, A. Rabell-Montiel, Jacinta Browne, S. D. Pyke, T. A. Anderson, C. M. Moran Jan 2017

Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material: A Longitudinal Study, A. Rabell-Montiel, Jacinta Browne, S. D. Pyke, T. A. Anderson, C. M. Moran

Articles

Commercially available ultrasound quality assurance test phantoms rely on the long-term acoustic stability of the tissue-mimicking-material (TMM). Measurement of the acoustic properties of the TMM can be technically challenging, and it is important to ensure its stability. The standard technique is to film-wrap samples of TMM and to measure the acoustic properties in a water bath. In this study, a modified technique was proposed whereby the samples of TMM are measured in a preserving fluid that is intended to maintain their characteristics. The acoustic properties were evaluated using a broadband pulse-echo substitution technique over the frequency range 4.5-50 MHz at …


An Audit Of A Hospital-Based Doppler Ultrasound Quality Control Protocol Using A Commercial String Doppler Phantom, S. Cournane, A. J. Fagan, Jacinta Browne Jan 2014

An Audit Of A Hospital-Based Doppler Ultrasound Quality Control Protocol Using A Commercial String Doppler Phantom, S. Cournane, A. J. Fagan, Jacinta Browne

Articles

Results from a four-year audit of a Doppler quality assurance (QA) program using a commercially available Doppler string phantom are presented. The suitability of the phantom was firstly determined and modifications were made to improve the reliability and quality of the measurements. QA of Doppler ultrasound equipment is very important as data obtained from these systems is used in patient management. It was found that if the braided-silk filament of the Doppler phantom was exchanged with an O-ring rubber filament and the velocity range below 50cm/s was avoided for Doppler quality control (QC) measurements, then the Maximum Velocity Accuracy (MVA) …


A Review Of Doppler Ultrasound Quality Assurance Protocols And Test Devices, Jacinta Browne Jan 2014

A Review Of Doppler Ultrasound Quality Assurance Protocols And Test Devices, Jacinta Browne

Articles

In this paper, an overview of Doppler ultrasound quality assurance (QA) testing will be presented in three sections. The first section will review the different Doppler ultrasound parameters recommended by professional bodies for use in QA protocols. The second section will include an evaluation and critique of the main test devices used to assess Doppler performance, while the final section of this paper will discuss which of the wide range of test devices have been found to be most suitable for inclusion in Doppler QA programmes. Pulsed Wave Spectral Doppler, Colour Doppler Imaging QA test protocols have been recommended over …


Ultrasound For Improved Crystallisation In Food Processing, N. Misra, Navneet Deora, Brijesh Tiwari, Patrick Cullen Jan 2013

Ultrasound For Improved Crystallisation In Food Processing, N. Misra, Navneet Deora, Brijesh Tiwari, Patrick Cullen

Articles

Within the food industry, controlling crystallisation is a key factor governing food structure, texture and consumer appeal, with some foods requiring the promotion of crystallisation in a controlled manner (e.g. chocolate) and others a check (e.g. in honey). Sonocrystallisation is the application of ultrasound energy to control the nucleation of a crystallisation process. The use of power ultrasound provides a non-invasive approach to producing crystals with desired properties. Sonocrystallisation facilitates process control, primarily by modulating crystal size distribution and morphology. This paper details the governing mechanisms of sonocrystallisation. Proven and potential applications of the process in foods, including chocolates, honey, …


Evaluation Of Cirs String Doppler Phantom As A Test Tool For Use In A Doppler Ultrasound Quality Assurance Program, Jacinta Browne, S. Cournane, Andrew Fagan Oct 2012

Evaluation Of Cirs String Doppler Phantom As A Test Tool For Use In A Doppler Ultrasound Quality Assurance Program, Jacinta Browne, S. Cournane, Andrew Fagan

Articles

Ultrasound Doppler systems are routinely used to perform blood flow velocity measurements which assist in the clinical assessment and diagnosis of vascular. Doppler measurements of peak velocities for vascular applications provide an indication of the degree of the stenosis which will ultimately assist in deciding how a patient is managed. It is imperative that Doppler systems are capable of accurately measuring blood flow velocities to ensure correct diagnosis and appropriate patient treatment; therefore such systems should be evaluated regularly as part of a Quality Assurance program. Although a range of Doppler test phantoms have been developed for quality control (QC) …


Comparative Review Of Imaging Methods Used For Diagnosing Renal Artery Stenosis (Ras), Deirdre King, Carmel Moran, Jacinta Browne Aug 2012

Comparative Review Of Imaging Methods Used For Diagnosing Renal Artery Stenosis (Ras), Deirdre King, Carmel Moran, Jacinta Browne

Articles

This comparative review examines the efficacy of different imaging methods to detect and quantify renal artery stenosis (RAS). Detection of RAS is important because it can lead to renovascular hypertension which is the most common form of secondary hypertension. Furthermore, it is important that a RAS is detected as early as possible as it is a potentially correctable cause of hypertension.1 If detected at an early stage RAS can potentially be treated using a minimally invasive drug treatment regimen rather than the more invasive percutaneous transluminal renal angioplasty without or with stent placement or surgery. Currently there are a …


Review Of Ultrasound Elastography Quality Control And Training Test Phantoms, S. Cournane, Andrew Fagan, Jacinta Browne Feb 2012

Review Of Ultrasound Elastography Quality Control And Training Test Phantoms, S. Cournane, Andrew Fagan, Jacinta Browne

Articles

While the rapid development of ultrasound elastography techniques in recent decades has sparked its prompt implementation in the clinical setting adding new diagnostic information to conventional imaging techniques, questions still remain as to its full potential and efficacy in the hospital environment. A limited number of technical studies have objectively assessed the full capabilities of the different elastography approaches, perhaps due, in part, to the scarcity of suitable tissue-mimicking materials and appropriately designed phantoms available. Few commercially-available elastography phantoms possess the necessary test target characteristics or mechanical properties observed clinically, or indeed reflect the lesion-to-background elasticity ratio encountered during clinical …


The Effects Of Fatty Desposits On The Accuracy Of The Fibroscan Liver Transient Elastography Ultrasound System, S. Cournane, Jacinta Browne, Andrew Fagan Jan 2012

The Effects Of Fatty Desposits On The Accuracy Of The Fibroscan Liver Transient Elastography Ultrasound System, S. Cournane, Jacinta Browne, Andrew Fagan

Articles

A new generation of ultrasound transient elastography (TE) systems have emerged which exploit the well-known correlation between the liver’s pathological and mechanical properties through measurements of the Young’s elastic modulus; however, little work has been carried out to examine the effect that fatty deposits may have on the TE measurement accuracy. An investigation was carried out on the effects on the measurement accuracy of a transient elastography ultrasound system, the Fibroscan®, caused by overlaying fat layers of varying thickness on healthy liver-mimicking phantoms, simulating in vivo conditions for obese patients. Furthermore, a steatosis effect similar to that in non-alcoholic fatty …


Comparative Imaging Study In Ultrasound Mri, Ct And Dsa Using A Multi-Modality Renal Artery Phantom, Deirdre King, Andrew Fagan, Carmel Moran, Jacinta Browne Jan 2011

Comparative Imaging Study In Ultrasound Mri, Ct And Dsa Using A Multi-Modality Renal Artery Phantom, Deirdre King, Andrew Fagan, Carmel Moran, Jacinta Browne

Articles

A range of anatomically-realistic multi-modality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in patients suffering from RAS is currently ill-defined, with the result that no one imaging modality has emerged as a gold standard technique for screening for this disease.

Methods: The phantoms, which contained a range of stenosis values (0, 30, 50, 70 and 85%), were designed for use with …


Quantitative Modelling Approaches For Ascorbic Acid Degradation And Non-Enzymatic Browning Of Orange Juice During Ultrasound Processing, Vasilis Valdramidis, Patrick Cullen, Brijesh Tiwari, Colm O’Donnell Jan 2010

Quantitative Modelling Approaches For Ascorbic Acid Degradation And Non-Enzymatic Browning Of Orange Juice During Ultrasound Processing, Vasilis Valdramidis, Patrick Cullen, Brijesh Tiwari, Colm O’Donnell

Articles

The objective of this study was to develop a deterministic modelling approach for non-enzymatic browning (NEB) and ascorbic acid (AA) degradation in orange juice during ultrasound processing. Freshly squeezed orange juice was sonicated using a 1,500 W ultrasonic processor at a constant frequency of 20 kHz and processing variables of amplitude level (24.4 – 61.0 μm), temperature (5 – 30 oC) and time (0 – 10 min). The rate constants of the NEB and AA were estimated by a primary model (zero and first order) while their relationship with respect to the processing factors was tested for a number of …


Development Of Renal Phantoms For The Evaluation Of Current And Emerging Ultrasound Technology, Deirdre King Jun 2009

Development Of Renal Phantoms For The Evaluation Of Current And Emerging Ultrasound Technology, Deirdre King

Doctoral

The primary aim of this project was to develop novel anatomically realistic renal phantoms for the evaluation of current and emerging ultrasound techniques capable of diagnosing all grades of renal artery stenosis. Renal artery stenosis is considered the most common cause of potentially curable secondary hypertension which if left untreated can lead to renal failure. Its early detection is very important as it offers the possibility of various drug treatments, which are considerably less invasive and poses less risk to the patient. Computer-aided modelling techniques were used to generate a range of anatomically realistic phantoms of the renal artery from …


Assessment Of The Acoustic Properties Of Common Tissue-Mimicking Test Phantoms, Jacinta Browne, K. Ramnarine, A. Watson, P. Hoskins Jan 2003

Assessment Of The Acoustic Properties Of Common Tissue-Mimicking Test Phantoms, Jacinta Browne, K. Ramnarine, A. Watson, P. Hoskins

Articles

Ultrasound (US) test phantoms incorporating tissue-mimicking materials (TMMs) play an important role in the quality control (QC) and performance testing of US equipment. Three commercially available TMMs (ZerdineTM from CIRS Inc.; condensed-milk-based gel from Gammex RMI; urethane-rubber-based from ATS Labs) and a noncommercial agar-based TMM, were investigated. Acoustic properties were measured over the frequency range 2.25 to 15 MHz at a range of ambient temperatures (10 to 35°C). The acoustic velocity of the TMMs remained relatively constant with increasing frequency. Only the agar-based TMM had a linear increase of attenuation with frequency, with the other materials exhibiting nonlinear responses to …