Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Physical Sciences and Mathematics

Magneto-Thermal Limitations In Superconducting Cavities At High Radio-Frequency Fields, I. Parajuli, G. Ciovati, A. Gurevich Jan 2024

Magneto-Thermal Limitations In Superconducting Cavities At High Radio-Frequency Fields, I. Parajuli, G. Ciovati, A. Gurevich

Physics Faculty Publications

The performance of superconducting radio-frequency Nb cavities at high radio-frequency (rf) fields in the absence of field emission can be limited by either a sharp decrease of the quality factor Q0(Bp) above peak surface magnetic fields Bp ∼100 mT or by a quench. We have measured Q0(Bp) at 2 K of several 1.3 GHz single-cell Nb cavities with different grain sizes, and with different ambient magnetic fields and cooldown rates below the critical temperature. Temperature mapping and a novel magnetic field mapping systems were used to find the location of “hot-spots” …


A Compton Transmission Polarimeter For Dc And Srf Electron Photo-Injectors, G. Blume, M. Bruker, C. Cuevas, H. Dong, Benjamin Fernandes Neres, P. Ghoshal, S. Gopinath, J. Grames, S. Gregory, G. Hays, C. Le Galliard, Sylvain Marsillac, B. Moffit, Thi Nguyen Trung, M. Poelker, R. Suleiman, E. Voutier, S. Zhang Jan 2024

A Compton Transmission Polarimeter For Dc And Srf Electron Photo-Injectors, G. Blume, M. Bruker, C. Cuevas, H. Dong, Benjamin Fernandes Neres, P. Ghoshal, S. Gopinath, J. Grames, S. Gregory, G. Hays, C. Le Galliard, Sylvain Marsillac, B. Moffit, Thi Nguyen Trung, M. Poelker, R. Suleiman, E. Voutier, S. Zhang

Physics Faculty Publications

A polarimeter was constructed to measure the longitudinal polarization of a spin-polarized electron beam at 5 and 7 MeV. The polarimeter takes advantage of Compton scattering between circularly polarized bremsstrahlung photons produced by a longitudinally polarized electron beam striking a copper radiator and the spin-polarized electrons orbiting the iron atoms of an analyzing magnet. This so-called Compton transmission polarimeter is compact and relatively inexpensive compared to Mott-scattering polarimeters because no spin manipulator is required. This work presents the design of the radiator, analyzing magnet, photon detector assembly, and data acquisition system of the Compton transmission polarimeter as well as beam …