Open Access. Powered by Scholars. Published by Universities.®
Physical Sciences and Mathematics Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Air Pollution, Indoor (2)
- Gases (2)
- Housing (2)
- Indoor air (2)
- Models, Theoretical (2)
-
- Vapor intrusion (2)
- Air Movements (1)
- Air Pollutants (1)
- Air Pollution (1)
- Air Pressure (1)
- Air pressure (1)
- Air quality (1)
- Air-water interface (1)
- Anisole (1)
- Atmospheric air (1)
- Atmospheric composition (1)
- BVOC (1)
- Benzene (1)
- Biogenic volatile organic compounds (1)
- Biomass burning (1)
- Brown cloud (1)
- Carboxylic Acids (1)
- Catechols (1)
- Combustion (1)
- Decision Making (1)
- Drones (1)
- Electron transfer (1)
- Fragmentation (1)
- Functionalization (1)
- Hazardous waste (1)
Articles 1 - 6 of 6
Full-Text Articles in Physical Sciences and Mathematics
Three-Dimensional Vapor Intrusion Modeling Approach That Combines Wind And Stack Effects On Indoor, Atmospheric, And Subsurface Domains, Elham Shirazi, Kelly G. Pennell
Three-Dimensional Vapor Intrusion Modeling Approach That Combines Wind And Stack Effects On Indoor, Atmospheric, And Subsurface Domains, Elham Shirazi, Kelly G. Pennell
Civil Engineering Faculty Publications
Vapor intrusion (IV) exposure risks are difficult to characterize due to the role of atmospheric, building and subsurface processes. This study presents a three-dimensional VI model that extends the common subsurface fate and transport equations to incorporate wind and stack effects on indoor air pressure, building air exchange rate (AER) and indoor contaminant concentration to improve VI exposure risk estimates. The model incorporates three modeling programs: (1) COMSOL Multiphysics to model subsurface fate and transport processes, (2) CFD0 to model atmospheric air flow around the building, and (3) CONTAM to model indoor air quality. The combined VI model predicts AER …
Unmanned Aerial Systems For Monitoring Trace Tropospheric Gases, Travis J. Schuyler, Marcelo I. Guzman
Unmanned Aerial Systems For Monitoring Trace Tropospheric Gases, Travis J. Schuyler, Marcelo I. Guzman
Chemistry Faculty Publications
The emission of greenhouse gases (GHGs) has changed the composition of the atmosphere during the Anthropocene. Accurately documenting the sources and magnitude of GHGs emission is an important undertaking for discriminating the contributions of different processes to radiative forcing. Currently there is no mobile platform that is able to quantify trace gases at altitudes(UASs) can be deployed on-site in minutes and can support the payloads necessary to quantify trace gases. Therefore, current efforts combine the use of UASs available on the civilian market with inexpensively designed analytical systems for monitoring atmospheric trace gases. In this context, this perspective introduces the …
Oxidation Of Substituted Catechols At The Air-Water Interface: Production Of Carboxylic Acids, Quinones, And Polyphenols, Elizabeth A. Pillar, Marcelo I. Guzman
Oxidation Of Substituted Catechols At The Air-Water Interface: Production Of Carboxylic Acids, Quinones, And Polyphenols, Elizabeth A. Pillar, Marcelo I. Guzman
Chemistry Faculty Publications
Anthropogenic activities contribute benzene, toluene, and anisole to the environment, which in the atmosphere are converted into the respective phenols, cresols, and methoxyphenols by fast gas-phase reaction with hydroxyl radicals (HO(•)). Further processing of the latter species by HO(•) decreases their vapor pressure as a second hydroxyl group is incorporated to accelerate their oxidative aging at interfaces and in aqueous particles. This work shows how catechol, pyrogallol, 3-methylcatechol, 4-methylcatechol, and 3-methoxycatechol (all proxies for oxygenated aromatics derived from benzene, toluene, and anisole) react at the air-water interface with increasing O3(g) during τc ≈ 1 μs contact time and contrasts their …
Air Exchange Rates And Alternatuve Vapor Entry Pathways To Inform Vapor Intrusion Exposure Risk Assessments, Rivka Reichman, Mohammadyousef Roghani, Evan J. Willett, Elham Shirazi, Kelly G. Pennell
Air Exchange Rates And Alternatuve Vapor Entry Pathways To Inform Vapor Intrusion Exposure Risk Assessments, Rivka Reichman, Mohammadyousef Roghani, Evan J. Willett, Elham Shirazi, Kelly G. Pennell
Civil Engineering Faculty Publications
Vapor intrusion (VI) is a term used to describe indoor air (IA) contamination that occurs due to the migration of chemical vapors in the soil and groundwater. The overall vapor transport process depends on several factors such as contaminant source characteristics, subsurface conditions, building characteristics, and general site conditions. However, the classic VI conceptual model does not adequately account for the physics of airflow around and inside a building and does not account for chemical emissions from alternative “preferential” pathways (e.g. sewers and other utility connections) into IA spaces. This mini-review provides information about recent research related to building air …
Nitrate Radicals And Biogenic Volatile Organic Compounds: Oxidation, Mechanisms And Organic Aerosol, Nga Lee Ng, Steven S. Brown, Alexander T. Archibald, Elliot Atlas, Ronald C. Cohen, John N. Crowley, Douglas A. Day, Neil M. Donahue, Juliane L. Fry, Hendrik Fuchs, Robert J. Griffin, Marcelo I. Guzman, Hartmut Hermann, Alma Hodzic, Yoshiteru Iinuma, José L. Jimenez, Astrid Kiendler-Scharr, Ben H. Lee, Deborah J. Luecken, Jingqiu Mao, Robert Mclaren, Anke Mutzel, Hans D. Osthoff, Bin Ouyang, Benedicte Picquet-Varrault, Ulrich Platt, Havala O. T. Pye, Yinon Rudich, Rebecca H. Schwantes, Manabu Shiraiwa, Jochen Stutz, Joel A. Thornton, Andreas Tilgner, Brent J. Williams, Rahul A. Zaveri
Nitrate Radicals And Biogenic Volatile Organic Compounds: Oxidation, Mechanisms And Organic Aerosol, Nga Lee Ng, Steven S. Brown, Alexander T. Archibald, Elliot Atlas, Ronald C. Cohen, John N. Crowley, Douglas A. Day, Neil M. Donahue, Juliane L. Fry, Hendrik Fuchs, Robert J. Griffin, Marcelo I. Guzman, Hartmut Hermann, Alma Hodzic, Yoshiteru Iinuma, José L. Jimenez, Astrid Kiendler-Scharr, Ben H. Lee, Deborah J. Luecken, Jingqiu Mao, Robert Mclaren, Anke Mutzel, Hans D. Osthoff, Bin Ouyang, Benedicte Picquet-Varrault, Ulrich Platt, Havala O. T. Pye, Yinon Rudich, Rebecca H. Schwantes, Manabu Shiraiwa, Jochen Stutz, Joel A. Thornton, Andreas Tilgner, Brent J. Williams, Rahul A. Zaveri
Chemistry Faculty Publications
Oxidation of biogenic volatile organic compounds (BVOC) by the nitrate radical (NO3) represents one of the important interactions between anthropogenic emissions related to combustion and natural emissions from the biosphere. This interaction has been recognized for more than 3 decades, during which time a large body of research has emerged from laboratory, field, and modeling studies. NO3-BVOC reactions influence air quality, climate and visibility through regional and global budgets for reactive nitrogen (particularly organic nitrates), ozone, and organic aerosol. Despite its long history of research and the significance of this topic in atmospheric chemistry, a number …
Us Residential Building Air Exchange Rates: New Perspectives To Improve Decision Making At Vapor Intrusion Sites, Rivka Reichman, Elham Shirazi, Donald G. Colliver, Kelly G. Pennell
Us Residential Building Air Exchange Rates: New Perspectives To Improve Decision Making At Vapor Intrusion Sites, Rivka Reichman, Elham Shirazi, Donald G. Colliver, Kelly G. Pennell
Civil Engineering Faculty Publications
Vapor intrusion (VI) is well-known to be difficult to characterize because indoor air (IA) concentrations exhibit considerable temporal and spatial variability in homes throughout impacted communities. To overcome this and other limitations, most VI science has focused on subsurface processes; however there is a need to understand the role of aboveground processes, especially building operation, in the context of VI exposure risks. This tutorial review focuses on building air exchange rates (AERs) and provides a review of literature related building AERs to inform decision making at VI sites. Commonly referenced AER values used by VI regulators and practitioners do not …