Open Access. Powered by Scholars. Published by Universities.®
Physical Sciences and Mathematics Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Breast--Radiography (2)
- 3-D microfabrication (1)
- 3-D nanofabrication (1)
- Amputation stumps--Ultrasonic imaging (1)
- Artificial implants (1)
-
- Artificial legs (1)
- Brain--Magentic Resonance Imagery (1)
- Breast Cancer (1)
- Breast--Cancer--Diagnosis (1)
- Diagnostic imaging (1)
- Dye lasers (1)
- Electrodes (1)
- Electroencephalography (1)
- Fabry–Pérot (1)
- Femtosecond lasers (1)
- Fiber tip sensors (1)
- Lasers (1)
- MATLAB (1)
- Medical Radiography--Digital techniques (1)
- Microfluidics (1)
- Multiphoton polymerization (1)
- Neural networks (Computer science) (1)
- Optical sensors (1)
- Optofluidic (1)
- Residual limbs (1)
- Tomography--Mathematical models (1)
- Two-photon absorption (1)
- Ultrafast lasers (1)
- Wavelets (Mathematics) (1)
- X-rays (1)
- Publication
- Publication Type
Articles 1 - 8 of 8
Full-Text Articles in Physical Sciences and Mathematics
3-D Fabry–Pérot Cavities Sculpted On Fiber Tips Using A Multiphoton Polymerization Process, Jonathan W. Smith, Jeremiah C. Williams, Joseph S. Suelzer, Nicholas G. Usechak, Hengky Chandrahalim
3-D Fabry–Pérot Cavities Sculpted On Fiber Tips Using A Multiphoton Polymerization Process, Jonathan W. Smith, Jeremiah C. Williams, Joseph S. Suelzer, Nicholas G. Usechak, Hengky Chandrahalim
Faculty Publications
This paper presents 3-D Fabry–Pérot (FP) cavities fabricated directly onto cleaved ends of low-loss optical fibers by a two-photon polymerization (2PP) process. This fabrication technique is quick, simple, and inexpensive compared to planar microfabrication processes, which enables rapid prototyping and the ability to adapt to new requirements. These devices also utilize true 3-D design freedom, facilitating the realization of microscale optical elements with challenging geometries. Three different device types were fabricated and evaluated: an unreleased single-cavity device, a released dual-cavity device, and a released hemispherical mirror dual-cavity device. Each iteration improved the quality of the FP cavity's reflection spectrum. The …
Monolithic Optofluidic Ring Resonator Lasers Created By Femtosecond Laser Nanofabrication, Hengky Chandrahalim, Qiushu Chen, Ali A. Said, Mark Dugan, Xudong Fan
Monolithic Optofluidic Ring Resonator Lasers Created By Femtosecond Laser Nanofabrication, Hengky Chandrahalim, Qiushu Chen, Ali A. Said, Mark Dugan, Xudong Fan
Faculty Publications
We designed, fabricated, and characterized a monolithically integrated optofluidic ring resonator laser that is mechanically, thermally, and chemically robust. The entire device, including the ring resonator channel and sample delivery microfluidics, was created in a block of fused-silica glass using a 3-dimensional femtosecond laser writing process. The gain medium, composed of Rhodamine 6G (R6G) dissolved in quinoline, was flowed through the ring resonator. Lasing was achieved at a pump threshold of approximately 15 μJ/mm2. Detailed analysis shows that the Q-factor of the optofluidic ring resonator is 3.3 × 104, which is limited by both solvent …
Quantitative Object Reconstruction Using Abel Transform Tomography And Mixed Variable Optimization, Kevin R. O'Reilly
Quantitative Object Reconstruction Using Abel Transform Tomography And Mixed Variable Optimization, Kevin R. O'Reilly
Theses and Dissertations
Researchers at the Los Alamos National Laboratory (LANL) are interested in quantitatively reconstructing an object using Abel transform x-ray tomography. Specifically, they obtain a radiograph by x-raying an object and attempt to quantitatively determine the number and types of materials and the thicknesses of each material layer. Their current methodologies either fail to provide a quantitative description of the object or are generally too slow to be useful in practice. As an alternative, the problem is modeled here as a mixed variable programming (MVP) problem, in which some variables are nonnumeric and for which no derivative information is available. The …
Pulse Coupled Neural Networks For The Segmentation Of Magnetic Resonance Brain Images, Shane L. Abrahamson
Pulse Coupled Neural Networks For The Segmentation Of Magnetic Resonance Brain Images, Shane L. Abrahamson
Theses and Dissertations
This research develops an automated method for segmenting Magnetic Resonance (MR) brain images based on Pulse Coupled Neural Networks (PCNN). MR brain image segmentation has proven difficult, primarily due to scanning artifacts such as interscan and intrascan intensity inhomogeneities. The method developed and presented here uses a PCNN to both filter and segment MR brain images. The technique begins by preprocessing images with a PCNN filter to reduce scanning artifacts. Images are then contrast enhanced via histogram equalization. Finally, a PCNN is used to segment the images to arrive at the final result. Modifications to the original PCNN model are …
Evaluation Of Segmentation For Bone Structures In 3d Rendering Of Ultrasound Residual Limb Images, Min C. Baker
Evaluation Of Segmentation For Bone Structures In 3d Rendering Of Ultrasound Residual Limb Images, Min C. Baker
Theses and Dissertations
Prosthetists today widely practice manual socket fitting, which produces subjective, inconsistent results. To address this problem, the Computerized Anthropometry Research and Design (CARD) Laboratory is developing a computer-aided socket design system that acquires ultrasound datasets of an amputee's residual limb, creates a 3D model, and helps identify load- bearing and pressure-relief areas. This research project focuses on providing 3D visualization of a residual limb to support the CARD Laboratory's efforts. Creating the 3D model of the skin and two bone contours requires two major steps: segmentation to identify the objects of interest and a surface tracking algorithm to generate the …
Computer-Aided Diagnosis Of Mammographic Masses, William E. Polakowski
Computer-Aided Diagnosis Of Mammographic Masses, William E. Polakowski
Theses and Dissertations
A new Model-Based Vision algorithm was developed to find possibly cancerous regions of interest (ROIs) in digitized mammograms and to correctly identify the malignant masses. This work has shown a sensitivity of 92 percent for locating malignant ROIs. The database contained 272 images (12 bit, 1OO microns) with 36 malignant and 53 benign mass images. Of the 53 biopsied benign cases, 74 percent were correctly classified. The Focus of Attention (segmentation) Module algorithm used a physiologically motivated Difference of Gaussians (DoG) filter to highlight mass-like regions in the mammogram. The Index Module labeled the regions by their hypothesized class: large …
Development Of A Mammographic Image Processing Environment Using Matlab, John L. Kelley
Development Of A Mammographic Image Processing Environment Using Matlab, John L. Kelley
Theses and Dissertations
Breast cancer is a disease that accounts for a disturbingly large number of deaths in females each year. Its prevalence is a topic of concern to all of us since it can affect our families, friends, and coworkers. Although mammographic screening is the most effective method currently available for the early detection of breast cancer, it is far from being an infallible procedure. Mammographic reading is error prone, partly because of the complexity of the task and partly because of the variability in human performance. Computers offer high reproducibility, and when used as an adjunct by the radiologist, may improve …
The Afit Multielectrode Array For Neural Recording And Simulation: Design, Testing, And Encapsulation, James R. Reid Jr
The Afit Multielectrode Array For Neural Recording And Simulation: Design, Testing, And Encapsulation, James R. Reid Jr
Theses and Dissertations
A two-dimensional, X-Y addressable, multiplexed array of 256 electrodes (16 x 16) has been fabricated using conventional semiconductor processing techniques. The individual electrodes are 16O microns x 160 microns, approximating the size of the cortical columns; the overall array size is 3910 microns x 3910 microns. The array has been fitted to a chronically implantable package and tested for several days in a simulated neural environment. EEG-like data were collected successfully from individual electrodes in the array. This array improves on a previous design of a 16 electrode (4 x 4) array that was chronically implanted on the cortex of …