Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Physical Sciences and Mathematics

Univariate Optimization Of Dispersive Liquid-Liquid Microextraction For Preconcentration Of Lead From Environmental Matrices, Samawah Region Prior To Quantification Using Flame Atomic Absorption Spectroscopy, Zaman Sahb Mehdi, Saher A. Ali Alshamkhawy Feb 2024

Univariate Optimization Of Dispersive Liquid-Liquid Microextraction For Preconcentration Of Lead From Environmental Matrices, Samawah Region Prior To Quantification Using Flame Atomic Absorption Spectroscopy, Zaman Sahb Mehdi, Saher A. Ali Alshamkhawy

Al-Bahir Journal for Engineering and Pure Sciences

In this work, a procedure based on dispersive liquid₋liquid microextraction for lead (Pb) preconcentration and quantification in an environmental matrix by flame atomic absorption spectroscopy (FAAS) was applied. A case-study approach was chosen to obtain further in-depth information on the Pb levels. The green chemistry principles have been applied for the pretreatment and preparation of real samples by focusing on some features such as the volume of reagents/sample, employ of energy efficient equipment, and production of waste. A univariate strategy was utilized to achieve the optimum extraction conditions. 1750 µL of acetonitrile containing 100 µL of carbon tetrachloride, were rapid …


Evaluation Of Iron Element By New Cpe Method And (Icp-Ms) In The Wastewater Of The Lifting And Treatment Stations, Mohammed Nasser Hussain, Ahmed Fadhil Khudhair, Hussain Jawad Ahmed Nov 2023

Evaluation Of Iron Element By New Cpe Method And (Icp-Ms) In The Wastewater Of The Lifting And Treatment Stations, Mohammed Nasser Hussain, Ahmed Fadhil Khudhair, Hussain Jawad Ahmed

Al-Bahir Journal for Engineering and Pure Sciences

A new micell-mediated phase separation technique has been created to preconcentrate levels of iron before measuring it using a UV-Vis spectrophotometer. The method is based on the extraction of iron from the 1-Nitroso-2- naphthol reagent using Triton X-114 in a cloud point extraction procedure, where the method's ideal conditions were attained. 0.2 mL of Triton X-114, 2.887 mmol. L-1 of 1-Nitroso-2-naphthol reagent, pH = 8, 60 ºC. The Iron detection limit for the method is 0.05 µg. mL-1, and the RSD% is 4.728 µg. mL-1. Linearity was maintained in the iron concentration range of 0.25 to 16 µg. mL-1. Furthermore, …