Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Medicine and Health Sciences

Novel Simulation To Avoid Bias In Measurement Of Hyperpolarized Pyruvate: Demonstrated In Phantom And In Vivo, Christopher M. Walker Dec 2016

Novel Simulation To Avoid Bias In Measurement Of Hyperpolarized Pyruvate: Demonstrated In Phantom And In Vivo, Christopher M. Walker

Dissertations & Theses (Open Access)

Dynamic nuclear polarization creates a transient hyperpolarized nuclear state that can dramatically increase the signal detected by magnetic resonance imaging. This signal increase allows real-time spectroscopic imaging of specific metabolites in vivo by magnetic resonance. Real-time imaging of both the spatial and chemical fate of hyperpolarized metabolites is showing great promise to meaningfully benefit clinical care of cancer patients. Imaging of hyperpolarized agents will have a larger clinical impact if it can function as a quantitative modality upon which clinical decisions can be made. However, quantitative measurement of hyperpolarized agents is currently difficult due to the restrictions imposed by the …


Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D. Dec 2016

Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D.

Dissertations & Theses (Open Access)

It has long been known that proton radiotherapy has an increased biological effectiveness compared to traditional x-ray radiotherapy. This arises from the clustered nature of DNA damage produced by the energy deposition of protons along their tracks in medium. This effect is currently quantified in clinical settings by assigning protons a relative biological effectiveness (RBE) value of 1.1 corresponding to 10% increased effectiveness compared to photon radiation. Numerous studies have shown, however, that the RBE value of protons is variable and can deviate substantially from 1.1, but experimental data on RBE and clinical evidence of its variability remains limited.

The …


An Automated Syringe Pump System For Improving The Reproducibility Of Dynamic Hyperpolarized Mri Phantoms, Harlee G. Harrison Aug 2016

An Automated Syringe Pump System For Improving The Reproducibility Of Dynamic Hyperpolarized Mri Phantoms, Harlee G. Harrison

Dissertations & Theses (Open Access)

AN AUTOMATED SYRINGE PUMP SYSTEM FOR IMPROVING THE REPRODUCIBILITY OF DYNAMIC HYPERPOLARIZED MRI PHANTOMS

Harlee Grace Harrison, B.S.

Advisory Professor: James Bankson, Ph.D.

Magnetic Resonance Imaging (MRI) is a powerful tool in the diagnosis of cancer due to its ability to provide good soft tissue contrast and image resolution without the use of ionizing radiation. The use of hyperpolarized pyruvate as a contrast agent for tumor metabolism during MR scans has the potential to provide information about tumor metabolism in vivo that is not available from traditional imaging measurements or any other method. Hyperpolarization is achieved through dynamic nuclear polarization. …


Identifying Treatment Planning System Errors In Iroc-Houston Head And Neck Phantom Irradiations, James Kerns Aug 2016

Identifying Treatment Planning System Errors In Iroc-Houston Head And Neck Phantom Irradiations, James Kerns

Dissertations & Theses (Open Access)

Treatment Planning System (TPS) errors can affect large numbers of cancer patients receiving radiation therapy. Using an independent recalculation system, the Imaging and Radiation Oncology Core-Houston (IROC-H) can identify institutions that have not sufficiently modelled their linear accelerators in their TPS model. Linear accelerator point measurement data from IROC-H’s site visits was aggregated and analyzed from over 30 linear accelerator models. Dosimetrically similar models were combined to create “classes”. The class data was used to construct customized beam models in an independent treatment dose verification system (TVS). Approximately 200 head and neck phantom plans from 2012 to 2015 were recalculated …


Measurement Of The Electron Return Effect Using Presage Dosimeter, Gye Won Choi Aug 2016

Measurement Of The Electron Return Effect Using Presage Dosimeter, Gye Won Choi

Dissertations & Theses (Open Access)

MR-guided radiation therapy (MRgRT) provides benefits such as superior soft tissue contrast, no imaging dose, and functional imaging capacities, but it also has concerns to be addressed. The electron return effect (ERE) refers to dose enhancement at the interface between different media, caused when radiation is delivered in the magnetic field. The ERE poses clinical concerns in MRgRT because it significantly enhances the dose at interfaces, and the intensity and pattern of the dose enhancement depends on many factors. The ERE results in a complex pattern of dose enhancement over a three-dimensional (3D) volume around tissue interfaces inside the patient …


Integration Of Multi-Platform High-Dimensional Omic Data, Xuebei An May 2016

Integration Of Multi-Platform High-Dimensional Omic Data, Xuebei An

Dissertations & Theses (Open Access)

The development of high-throughput biotechnologies have made data accessible from different platforms, including RNA sequencing, copy number variation, DNA methylation, protein lysate arrays, etc. The high-dimensional omic data derived from different technological platforms have been extensively used to facilitate comprehensive understanding of disease mechanisms and to determine personalized health treatments. Although vital to the progress of clinical research, the high dimensional multi-platform data impose new challenges for data analysis. Numerous studies have been proposed to integrate multi-platform omic data; however, few have efficiently and simultaneously addressed the problems that arise from high dimensionality and complex correlations.

In my dissertation, I …