Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Medicine and Health Sciences

Does Footfall Pattern In Forefoot Runners Change Over A Prolonged Run?, Carl W. Jewell Dec 2014

Does Footfall Pattern In Forefoot Runners Change Over A Prolonged Run?, Carl W. Jewell

Masters Theses

There has been much debate on the benefits of a forefoot versus rearfoot strike pattern in distance running in terms of performance and injury prevalence. Shock attenuation occurs more prominently in soft tissues at impact in forefoot runners compared to the passive skeletal loading in rearfoot runners. Recent studies indicate that a forefoot strike pattern may not be maintainable over long distance efforts. Therefore, this study tested the hypothesis that habitual forefoot runners could not maintain their strike pattern throughout a prolonged, intensive run.

Fourteen forefoot runners ran to voluntary exhaustion on an instrumented force treadmill (average run duration: 15.4±2.2 …


Biomechanical Joint Demands And Functional Outcomes During Manual Wheelchair Use In Pediatric Patients With Spinal Cord Injury, Christine M. Aurit Dec 2014

Biomechanical Joint Demands And Functional Outcomes During Manual Wheelchair Use In Pediatric Patients With Spinal Cord Injury, Christine M. Aurit

Theses and Dissertations

The biomechanical demands of the upper extremities (UEs) during pediatric manual wheelchair (MWC) use have not been fully explored. Children who use MWCs for mobility engage in a range of functional activities that may place large biomechanical demands on the UEs leading to a high risk on overuse injuries. This study aims to analyze the kinematics and kinetics of pediatric manual wheelchair use during propulsion, starting, stopping and weight relief tasks. Fourteen pediatric patients with spinal cord injury were recruited and data were collected using a 14-camera Vicon MX motion analysis system (Oxford Metric Group, Oxford, UK) and a SmartWheel …


The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari Sep 2014

The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari

Electronic Thesis and Dissertation Repository

Abstract:

The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries

Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.

Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …


Kinetic Asymmetries During Submaximal And Maximal Speed Running, Devon H. Frayne Aug 2014

Kinetic Asymmetries During Submaximal And Maximal Speed Running, Devon H. Frayne

Masters Theses

An important issue for sports scientists, coaches and athletes is an understanding of the factors within a running stride that can enhance or limit maximal running speed. Previous research has identified many sprint-related parameters as potential kinetic limiters of maximal Center of Mass velocity (Chapman and Caldwell, 1983b; Weyand et al., 2001). Bilateral asymmetry is present for many of these parameters during running; however the degree to which such asymmetries change as running speed increases is unknown. It was hypothesized that asymmetries in key sprinting parameters would be larger at maximal speed than all other tested speeds. Kinematics and kinetics …


Quantifying And Comparing The Head Impact Biomechanics Of Different Player Positions For Canadian University Football, Kody Campbell Jul 2014

Quantifying And Comparing The Head Impact Biomechanics Of Different Player Positions For Canadian University Football, Kody Campbell

Electronic Thesis and Dissertation Repository

Differences between Canadian and American football could affect the magnitudes of head impacts and risk of concussion to Canadian players. This study sought to quantify and compare the number, magnitude, and location of impacts that Canadian University football players of different positions experienced during games and practice in a season. A kinematic measuring device collected the linear accelerations and rotational velocities of the head from impacts experienced by players competing in practices and games. The impact magnitudes that were experienced in games were significantly larger than in practice. The offensive back position and wide receiver position had significantly larger peak …


Using The Microsoft Kinect To Assess Human Bimanual Coordination, Joshua James Liddy Jul 2014

Using The Microsoft Kinect To Assess Human Bimanual Coordination, Joshua James Liddy

Open Access Theses

Optical marker-based systems are the gold-standard for capturing three-dimensional (3D) human kinematics. However, these systems have various drawbacks including time consuming marker placement, soft tissue movement artifact, and are prohibitively expensive and non-portable. The Microsoft Kinect is an inexpensive, portable, depth camera that can be used to capture 3D human movement kinematics. Numerous investigations have assessed the Kinect's ability to capture postural control and gait, but to date, no study has evaluated it's capabilities for measuring spatiotemporal coordination. In order to investigate human coordination and coordination stability with the Kinect, a well-studied bimanual coordination paradigm (Kelso, 1984, Kelso; Scholz, & …


Is There A Relationship Between Hip Structure, Hip Muscle Strength, And Lower Extremity Frontal Plane Kinematics During Treadmill Running?, Michael William Robinson Baggaley Jan 2014

Is There A Relationship Between Hip Structure, Hip Muscle Strength, And Lower Extremity Frontal Plane Kinematics During Treadmill Running?, Michael William Robinson Baggaley

Theses and Dissertations--Kinesiology and Health Promotion

INTRODUCTION: Excessive hip adduction (HADD) has been associated with a number of lower extremity overuse injuries, and it has been suggested that it may be the result of reduced strength of the hip abduction musculature. Hip structure has been postulated to influence both hip abduction (HABD) strength and HADD. The purpose of this study was to investigate the relationship between hip structure, HABD strength, and frontal plane kinematics during running. METHODS: Peak isometric HABD strength, lower extremity kinematics, femoral neck-shaft angle (NSA), and pelvis width-femur length (pw-fl) ratio were recorded for 25 female subjects. Pearson correlations (P < .05) were performed between variables. RESULTS: A fair relationship was observed between femoral NSA and HABD strength (r = …


Evaluation And Characterization Of The Biomechanical Properties Of Tissue Engineered Vascular Grafts Implanted In The Arterial Circulation, Brooks Van Udelsman Jan 2014

Evaluation And Characterization Of The Biomechanical Properties Of Tissue Engineered Vascular Grafts Implanted In The Arterial Circulation, Brooks Van Udelsman

Yale Medicine Thesis Digital Library

We used a murine model to assess the in vivo evolving biomechanical properties of tissue engineered vascular grafts (TEVGs) implanted in the arterial circulation. The initial polymeric tubular scaffold was fabricated from (poly)lactic acid (PLA) and coated with a 50:50 copolymer of (poly)caprolactone and (poly)lactic acid (P[PC/LA]). Following seeding with syngeneic bone marrow derived mononuclear cells, the TEVGs (n=50) were implanted as aortic interposition grafts in wild-type mice and monitored serially using ultrasound. A custom biaxial mechanical testing device was used to quantify in vitro the circumferential and axial mechanical properties of grafts explanted at 3 or 7 months. At …


Neuromuscular Factors Affecting Stretch-Induced Torque Loss, Gabriel Siqueira Trajano Jan 2014

Neuromuscular Factors Affecting Stretch-Induced Torque Loss, Gabriel Siqueira Trajano

Theses: Doctorates and Masters

The mechanisms underpinning the immediate torque loss induced by acute, static muscle stretching are still not clear. The current research was designed to examine the neuromuscular factors influencing this torque loss. In Study 1, the contributions of central versus peripheral factors to the stretch-induced torque loss were investigated. Measures of central drive, including the EMG amplitude normalised to the muscle compound action potential amplitude (EMG:M), percent voluntary activation (%VA) and first volitional wave amplitude (V:M), and measures of peripheral function, including the twitch peak torque and 20:80 Hz tetanic torque ratio were made before, and immediately and 15 min after …