Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 14 of 14

Full-Text Articles in Medicine and Health Sciences

Improving Dose-Response Correlations For Locally Advanced Nsclc Patients Treated With Imrt Or Pspt, Yulun He May 2023

Improving Dose-Response Correlations For Locally Advanced Nsclc Patients Treated With Imrt Or Pspt, Yulun He

Dissertations & Theses (Open Access)

The standard of care for locally advanced non-small cell lung cancer (NSCLC) is concurrent chemo-radiotherapy. Despite recent advancements in radiation delivery methods, the median survival time of NSCLC patients remains below 28 months. Higher tumor dose has been found to increase survival but also a higher rate of radiation pneumonitis (RP) that affects breathing capability. In fear of such toxicity, less-aggressive treatment plans are often clinically preferred, leading to metastasis and recurrence. Therefore, accurate RP prediction is crucial to ensure tumor coverage to improve treatment outcome. Current models have associated RP with increased dose but with limited accuracy as they …


Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower Aug 2019

Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower

Dissertations & Theses (Open Access)

Proton therapy is a radiotherapy modality that can offer a better physical dose distribution when compared to photon radiotherapy by taking advantage of the Bragg peak, a narrow region of rapid energy loss. Proton therapy is also known to offer an enhanced relative biological effectiveness (RBE) compared to photons. In the current clinical standard, RBE is fixed at 1.1 at all points along the proton beam, meaning protons are assumed to require 10% less dose than photons to achieve target coverage and organ at risk (OAR) sparing. However, there is mounting clinical evidence, and a significant number of in vitro …


Evaluation Of Presage® As A 3d Dose Verification Tool In Proton Beams, Mitchell Carroll Dec 2018

Evaluation Of Presage® As A 3d Dose Verification Tool In Proton Beams, Mitchell Carroll

Dissertations & Theses (Open Access)

Radiotherapy techniques have advanced and radiation dose plans have become much more complex over the last decade. This is especially true in proton therapy, which involves extremely steep dose gradients as a result of positioning the Bragg peak to cover the volumes to be treated. The Bragg peak can be shifted significantly in the patient as a result of nonuniformities in the tissue composition in its path, which can result in treatment complications. Some traditional dose verification tools used in proton beam commissioning and treatment plan verification are film, TLD, and ionization chambers. Such 0D and 2D dosimeters are incapable …


Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D. Dec 2016

Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D.

Dissertations & Theses (Open Access)

It has long been known that proton radiotherapy has an increased biological effectiveness compared to traditional x-ray radiotherapy. This arises from the clustered nature of DNA damage produced by the energy deposition of protons along their tracks in medium. This effect is currently quantified in clinical settings by assigning protons a relative biological effectiveness (RBE) value of 1.1 corresponding to 10% increased effectiveness compared to photon radiation. Numerous studies have shown, however, that the RBE value of protons is variable and can deviate substantially from 1.1, but experimental data on RBE and clinical evidence of its variability remains limited.

The …


Development And Implementation Of An Anthropomorphic Head & Neck Phantom For The Assessment Of Proton Therapy Treatment Procedures, Daniela Branco Aug 2016

Development And Implementation Of An Anthropomorphic Head & Neck Phantom For The Assessment Of Proton Therapy Treatment Procedures, Daniela Branco

Dissertations & Theses (Open Access)

Proton therapy has been used to treat cancer for more than 50 years, and over the past decade, its use has grown rapidly. One of the main goals of modern radiation therapy is to deliver a high dose to the planning target volume (PTV) with minimal exposure and damage to the surrounding healthy tissue. Protons offer a unique advantage over photon radiotherapy in that they deposit dose over a finite range, in contrast to the more gradual energy deposition of photon and electron beams. At present, 23 proton centers are in operation in the United States and another 13 centers …


Assessment Of Uncertainty In Planning And Dose Delivery Of Proton Therapy In An Iroc- Houston Qa Phantom Due To Variable Ct Technique And Proton Energy, Mattie M. Mcinnis Aug 2015

Assessment Of Uncertainty In Planning And Dose Delivery Of Proton Therapy In An Iroc- Houston Qa Phantom Due To Variable Ct Technique And Proton Energy, Mattie M. Mcinnis

Dissertations & Theses (Open Access)

As proton therapy increases in popularity, so does the need for effective quality assurance. Proton therapy institutions participating in NCI funded clinical trials rely heavily on the credentialing and auditing services of IROC-H and therefore the process must be well understood. The purpose of this project is to understand the uncertainties in proton therapy treatment planning for the IROC-H proton phantom QA program due to variations in CT technique and proton energy. It was hypothesized that variations in CT technique and proton energy will alter the delivered dose distributions of typical proton treatments by reducing the percent of passing pixels …


Volumetric Scintillation Dosimetry For Scanned Proton Beams, Daniel G. Robertson Aug 2014

Volumetric Scintillation Dosimetry For Scanned Proton Beams, Daniel G. Robertson

Dissertations & Theses (Open Access)

Scanned beam proton therapy is a promising cancer treatment modality which is becoming more widely available with the increasing number of proton radiotherapy centers. Scanned proton beams can produce complex 3D dose distributions, presenting a challenge for adequate quality assurance testing. Because each scanned beam dose measurement requires the delivery of the entire field, multiple measurements can be time consuming. These quality assurance challenges limit the number of patients who can be treated with this modality. The overall objective of this project is to increase the safety and availability of complex proton therapy treatments by developing a fast volumetric scintillation …


Image-Guided Proton Therapy For Online Dose-Evaluation And Adaptive Planning, Joey P. Cheung May 2014

Image-Guided Proton Therapy For Online Dose-Evaluation And Adaptive Planning, Joey P. Cheung

Dissertations & Theses (Open Access)

The main advantage for using protons in radiotherapy is their finite range in patients, allowing for potential improved sparing of normal tissues. However, this comes at a cost of increased sensitivity to range uncertainties. Density changes along the beam path will affect the proton range and the resultant dose distribution, making it difficult to estimate the impact of visible anatomic changes to the patient dose distribution. In order to better understand the effect of anatomy change on proton dose, some form of treatment-time verification is required and methods to correct for observed changes would be beneficial. Therefore, this project aims …


Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley Dec 2013

Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley

Dissertations & Theses (Open Access)

Although frequently cured of Hodgkin lymphoma, adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states of respiration can enable superior sparing of healthy tissue near moving targets, compared to other motion mitigation strategies. Furthermore, carbon-ion therapy can sometimes provide greater relative biological effectiveness (RBE) for cell sterilization in a target but nearly equivalent RBE in tissue upstream of the target, compared to proton therapy. Thus, we expected that for some …


Development And Implementation Of A Dynamic Heterogeneous Proton Equivalent Anthropomorphic Thorax Phantom For The Assessment Of Scanned Proton Beam Therapy, James L. Neihart Aug 2013

Development And Implementation Of A Dynamic Heterogeneous Proton Equivalent Anthropomorphic Thorax Phantom For The Assessment Of Scanned Proton Beam Therapy, James L. Neihart

Dissertations & Theses (Open Access)

DEVELOPMENT AND IMPLEMENTATION OF A DYNAMIC HETEROGENEOUS PROTON EQUIVALENT ANTHROPOMORPHIC THORAX PHANTOM FOR THE ASSESSMENT OF SCANNED PROTON BEAM THERAPY

by

James Leroy Neihart, B.S.

APPROVED:


______________________________
David Followill, Ph.D.


______________________________
Peter Balter, Ph.D.


______________________________
Narayan Sahoo, Ph.D.


______________________________
Kenneth Hess, Ph.D.


______________________________
Paige Summers, M.S.

APPROVED:


____________________________

Dean, The University of Texas

Graduate School of Biomedical Sciences at Houston

DEVELOPMENT AND IMPLEMENTATION OF A DYNAMIC HETEROGENEOUS PROTON EQUIVALENT ANTHROPOMORPHIC THORAX PHANTOM FOR THE ASSESSMENT OF SCANNED PROTON BEAM THERAPY




A

THESIS

Presented to the Faculty of
The University of Texas
Health Science Center at Houston
and
The University of …


Improving Cervical Cancer Nodal Boost Radiation Therapy By Quantifying Uncertainties And Exploring Advanced Radiation Therapy Modalities, Zhiqian Yu May 2013

Improving Cervical Cancer Nodal Boost Radiation Therapy By Quantifying Uncertainties And Exploring Advanced Radiation Therapy Modalities, Zhiqian Yu

Dissertations & Theses (Open Access)

Radiation therapy for patients with intact cervical cancer is frequently delivered using primary external beam radiation therapy (EBRT) followed by two fractions of intracavitary brachytherapy (ICBT). Although the tumor is the primary radiation target, controlling microscopic disease in the lymph nodes is just as critical to patient treatment outcome. In patients where gross lymphadenopathy is discovered, an extra EBRT boost course is delivered between the two ICBT fractions. Since the nodal boost is an addendum to primary EBRT and ICBT, the prescription and delivery must be performed considering previously delivered dose. This project aims to address the major issues of …


Evaluation Of Polymer Gel Dosimeters For Measurements Of Dose And Let In Proton Beams, Kevin M. Vredevoogd Dec 2012

Evaluation Of Polymer Gel Dosimeters For Measurements Of Dose And Let In Proton Beams, Kevin M. Vredevoogd

Dissertations & Theses (Open Access)

This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and LET-Meter dosimeters, for LET measurement. All dosimeters were read out using an OCT scanner. The basic characteristics of the BANGkits™ were assessed in a series of photon and electron irradiations. The dose-response relationship was found to be sigmoidal with a threshold for response of approximately 15 cGy. The active region of the dosimeter, the volume in …


Risk Of Second Malignant Neoplasms Following Proton Arc Therapy And Volumetric Modulated Arc Therapy For Prostate Cancer, Laura A. Rechner May 2011

Risk Of Second Malignant Neoplasms Following Proton Arc Therapy And Volumetric Modulated Arc Therapy For Prostate Cancer, Laura A. Rechner

Dissertations & Theses (Open Access)

The risk of second malignant neoplasms (SMNs) following prostate radiotherapy is a concern due to the large population of survivors and decreasing age at diagnosis. It is known that parallel-opposed beam proton therapy carries a lower risk than photon IMRT. However, a comparison of SMN risk following proton and photon arc therapies has not previously been reported. The purpose of this study was to predict the ratio of excess relative risk (RRR) of SMN incidence following proton arc therapy to that after volumetric modulated arc therapy (VMAT). Additionally, we investigated the impact of margin size and the effect …


Implementation Of An Anthropomorphic Phantom For The Evaluation Of Proton Therapy Treatment Procedures, Ryan L. Grant May 2010

Implementation Of An Anthropomorphic Phantom For The Evaluation Of Proton Therapy Treatment Procedures, Ryan L. Grant

Dissertations & Theses (Open Access)

With an increasing number of institutions offering proton therapy, the number of multi-institutional clinical trials involving proton therapy will also increase in the coming years. The Radiological Physics Center monitors sites involved in clinical trials through the use of site visits and remote auditing with thermoluminescent dosimeters (TLD) and mailable anthropomorphic phantoms. Currently, there are no heterogeneous phantoms that have been commissioned to evaluate proton therapy. It was hypothesized that an anthropomorphic pelvis phantom can be designed to audit treatment procedures (patient simulation, treatment planning and treatment delivery) at proton facilities to confirm agreement between the measured dose and calculated …