Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Virginia Commonwealth University

Endodontics and Endodontology

Root canal

Articles 1 - 7 of 7

Full-Text Articles in Medicine and Health Sciences

Comparison Of Endodontic Treatment Planning Decisions Using Cone Beam Computed Tomography Versus Periapical Radiography In Previously Endodontically Treated Molars, Sarah Alkanderi Jan 2020

Comparison Of Endodontic Treatment Planning Decisions Using Cone Beam Computed Tomography Versus Periapical Radiography In Previously Endodontically Treated Molars, Sarah Alkanderi

Theses and Dissertations

Objectives: The aim of this study was to determine if treatment plans differ when evaluating previously endodontically treated molars using periapical images (PA’s) alone versus PA’s and CBCT.

Methods: A retrospective cohort chart review was conducted including 67 previously treated molars that had a CBCT taken. Two calibrated board-certified endodontists evaluated standard PA’s. A data sheet questionnaire regarding radiographic findings and treatment plan decisions was completed. Two weeks later, the same steps were repeated but the examiners evaluated both PA’s and CBCT images and again arrived at a recommended treatment plan.

Results: Agreement between raters was assessed with Cohen’s Kappa …


Potential Antimicrobial Methods For Provisionalizing Teeth After Endodontic Treatment, Laura T. Garden Jan 2018

Potential Antimicrobial Methods For Provisionalizing Teeth After Endodontic Treatment, Laura T. Garden

Theses and Dissertations

POTENTIAL ANTIMICROBIAL METHODS FOR PROVISIONALIZING TEETH AFTER ENDODONTIC TREATMENT

By Laura T. Garden, DDS

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Dentistry at Virginia Commonwealth University.

Virginia Commonwealth University, 2018

Thesis Advisor: Garry Myers, DDS

Department of Endodontics

Objective:To evaluate the effectiveness of a Chlorhexidine soaked cotton pellet on bacterial leakage.

Methods: Fifty-one extracted teeth, including six controls, were instrumented, obturated, and sealed with either a cotton pellet (CP), 2% Chlorhexidine soaked cotton pellet (CHX), or a Permaflo orifice barrier (OB). Each root was suspended between two chambers: the …


A Comparative Study Of Intraradicular Enterococcus Faecalis Biofilm Removal With Three Root Canal Treatment Systems: A Scanning Electron Microscopy Evaluation, Cyrous Ardalan Jan 2017

A Comparative Study Of Intraradicular Enterococcus Faecalis Biofilm Removal With Three Root Canal Treatment Systems: A Scanning Electron Microscopy Evaluation, Cyrous Ardalan

Theses and Dissertations

The objective of this study was to evaluate the biofilm removal efficacy of three root canal treatment systems: ProUltra® PiezoFlow™, traditional needle irrigation, and the GentleWave® system in an ex-vivo benchtop study. Twenty-four extracted maxillary and mandibular molars were selected. Teeth were all instrumented to a master apical file size #25 with 4% taper. Teeth were then randomly divided into four experimental groups and two control groups. The root canals were inoculated with a culture of Enterococcus faecalis and incubated for five weeks to form a biofilm. Each group was then treated with one of the different root canal treatment …


Comparing Cyclic Fatigue Of The New Gt® Series X(Tm) Files To The Endo Sequence™ Rotary Instruments, Nathan Wayment Apr 2009

Comparing Cyclic Fatigue Of The New Gt® Series X(Tm) Files To The Endo Sequence™ Rotary Instruments, Nathan Wayment

Theses and Dissertations

The purpose of this study was to examine the number of rotations to failure of two different rotary file systems, EndoSquence Brassler USA (Savannah, GA) and GT(TM) series X(TM). Files sizes 20,30,40 with 0.04, 0.06 tapers of GT series X and Endo Sequence files size and taper used were 20, 30, 40 with 0.04 and 0.06 taper. Like tip and tapers were compared between systems. All files tested were 25mm in length. Files were allocated into 12 groups of 10 files each, and mounted to a universal testing machine. Each file was rotated at 300 rpms until fractured occurred. The …


Comparative Analysis Of Torsional Strength Between Profile® Gt® And Gt® Series X(Tm) Nickel Titanium Rotary Instruments, Jake Reynolds Apr 2009

Comparative Analysis Of Torsional Strength Between Profile® Gt® And Gt® Series X(Tm) Nickel Titanium Rotary Instruments, Jake Reynolds

Theses and Dissertations

The purpose of this study was to compare the resistance to fracture by the twisting of two nickel titanium (NiTi) rotary file systems. The Profile® GT® (GT) and the GT® Series X(TM) (GTX) files were tested to analyze the maximum torsional strength and the maximum angular deflection at the time of separation of the files. For each system, ten new files were tested at each of the following eight taper/size designations for a total of 160 files: 20/0.04, 20/0.06, 30/0.04, 30/0.06, 30/0.08, 40/0.04, 40/0.06, and 40/0.08. The American National Standards Institute / American Dental Association Specification No. 28 was implemented …


Comparing Cyclic Fatigue Of The New Gt® Series Xtm Files To The Original Profile® Gt® Rotary Instruments, Steven Osmond Apr 2009

Comparing Cyclic Fatigue Of The New Gt® Series Xtm Files To The Original Profile® Gt® Rotary Instruments, Steven Osmond

Theses and Dissertations

The purpose of this study was to test the number of rotations to fracture of the M-Wire GT® Series X(TM) rotary files compared to the original ProFile® GT® rotary files in a simulated curved canal. Eighty GT® Series X(TM) files of 25mm length were divided into eight groups of ten, one for each of the new GT® Series X(TM) files. Eighty original ProFile® GT® files of 25mm length were divided into eight groups of the same tip and taper sizes consistent with the GT® Series X(TM) file groups. Files were rotated at 300 rpm. While the angle may have slightly …


Physical And Chemical Properties Of A New Mineral Trioxide Aggregate Material, David Lowell Spencer Jan 2004

Physical And Chemical Properties Of A New Mineral Trioxide Aggregate Material, David Lowell Spencer

Theses and Dissertations

The objective of this study was to compare the time to final set and compressive strength of the white mineral trioxide aggregate (MTA) formulation to the original grey MTA. To test compressive strength, each MTA formulation was placed into Teflon split molds for four hours at 37° Celsius (C) and 100% humidity. Compressive strength of both MTA formulations was measured at 24 hours (n=12) and 21 days (n=19) using an Instron Testing Machine. For determination of time to final set, each MTA formulation (n=6) was placed into a metal mold and maintained at 37° C and 100% humidity while setting. …