Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 4 of 4
Full-Text Articles in Medicine and Health Sciences
Volumetric Analysis Of The Lips In Aging African American And Caucasian Females, David William Bowen
Volumetric Analysis Of The Lips In Aging African American And Caucasian Females, David William Bowen
All ETDs from UAB
The objective of this study was to perform a volumetric analysis of the lips at rest and upon smiling in African American and Caucasian females distributed throughout five age groups. Materials and Methods: Three-dimensional surface facial images of 100 African American females and 100 Caucasian females were obtained using the 3dMDTMface system (3dMDface, Atlanta GA). Images were analyzed using the Aging Evaluation Analysis (AEVA) software (Eotech, Paris, France) to assess lip volume at rest and upon smile. The following linear measurements were also calculated upon smiling and non-smiling: subnasale-stomion superius, commissure-commissure, stomion inferius-labiomental sulcus. Gingival display and crown length was …
Effect Of Margin Design On Fracture Strength Of Zirconia Crown, Eleni Voltidi
Effect Of Margin Design On Fracture Strength Of Zirconia Crown, Eleni Voltidi
All ETDs from UAB
Purpose: To compare the fracture load of monolithic Zirconia crowns and E-max crowns with different margin designs and to create a guideline for margin design for monolithic Zirconia crowns. Methods: Digital design of prep maxillary molar tooth was performed with TOC 20 degrees and occlusal reduction 1 mm and axial reduction 1 mm and two different margin designs (group 1: Shoulder 0.8mm group 2: Light Chamfer 0.3mm). Dies were milled using Ultra Crystal material. Monolithic Zirconia crowns were milled (n=9 in group 1 and n=8 in group 2). Crowns were cemented with Rely X luting Plus. The specimens were stored …
Retentive Strength At The Zirconia Implant Abutment And Titanium Base Interface With Different Surface Treatments, Celin Arce
All ETDs from UAB
Screw-retained zirconia implant crowns with an internal titanium base have favorable mechanical properties compared to single piece zirconia implant crowns; however, they require adequate bonding between the zirconia crown and the titanium base. This study measures the retention between a titanium base and a full contour zirconia implant crown following different surface treatments of their bonded surfaces. Full contour zirconia implant crowns were fabricated to fit a 3.5mm titanium base. The crowns were bonded to the titanium bases following 4 protocols (n=15): no surface treatment (Group 1), MDP-primer on the intaglio of crown and exterior of base (Group 2), alumina …
A Comparison Of Soft Tissue Topographical Norms For The Local Ethnic People Of Zimbabwe And African American Norms Based On 3dmd Soft Tissue Photography, Elvin Bhaskar
All ETDs from UAB
Introduction: The purpose of this study is to determine the soft tissue topographical norms for the local ethnic people of Zimbabwe and compare them with the African American norms based on 3dMD soft tissue photography. The rationale for the study is to evaluate how the soft tissue drape over the facial skeleton correlates with the different soft tissue analysis widely available today. This study seeks to establish an average base on which clinicians can treat people according to their cultural esthetic perceptions. Previous reported studies only evaluate small numbers of populations and it is well known that different races and …